Tri flo - 1

T R IFLO FLOW METER “PATENTED” Perfecting Measurement FEATURES • • • • • • • Complete interchangeability of components between three different sizes of flow meters (1”, 1½” and 2”). Simple design of the meters reduces both parts costs and field servicing time. Patented design. (Patent No. US 7,886,616 B1) Internals accessible without having to break piping connections. Hard Carbon Bearings. System accuracy of ±1% or better. NPT end fittings. FLOWMETER SPECIFICATIONS 1” Flowmeter with Magnetic Coil 5 GPM to 75 GPM turn down 15:1 Linearity: Less than ±1% Repeatable: 4 GPM to 85 GPM turn down 21:1 Repeatability: The Hoffer TriFlo provides both system integrators and operators with the most flexible measurement solutions for liquid flow including produced water flow and hydrocarbon condensate flow measurement. The Hoffer TriFlo meter provides complete interchangeability of components between three different sizes of flow meters (1”, 1½” and 2”), all of which can be accessed without having to break piping connections. The TriFlo’s are offered both with complete inline meter bodies and in OEM versions which allow the integrator/manufacturer to install the meters into their own piping system. The use of identical internal parts for all three meter sizes reduces the number of spare parts that a service company or operator needs to stock by a factor of 3. The simple design of the meters and the ability to access and replace the internal components further reduces both parts costs as well as field servicing time. Linear Range: Less than ±0.1% 1.5” Flowmeter with Magnetic Coil Linear Range: 13 GPM to 180 GPM turn down 14:1 Linearity: Less than ±1% Repeatable: 11 GPM to 188 GPM turn down 17:1 Repeatability: Less than ±0.1% 2” Flowmeter with Magnetic Coil Linear Range: 20 GPM to 260 GPM turn down 14:1 Linearity: Less than ±1% Repeatable: 17 GPM to 280 GPM turn down 17:1 Repeatability: Less than ±0.1% Pressure Rating and Suggested Maximum Working Pressure 1” 4,000 psi 1.5” 2,800 psi 2” 2,500 psi Pressure Loss at Maximum Linear Flow 1” 2.3 psid 1.5” 1.1 psid 2” .55 psid Operating Temperature -65°F to +250°F with a Butyl, Buna-n (Nitril) O-ring. Lower temperatures can be obtained with proper O-ring material selection.

Open the catalog to page 1
Tri flo - 2

ORDERING INFORMATION Basic Model HTF Configuration (___) - (___) - (___) - (___) - (___) - (___) (M ) METER COMPLETE WITH HOUSING (C) CALIBRATED INSERT ONLY (K) FIELD REPAIR KIT SIZE (Applies only to complete meters) (1) (11/2) (2) (X) BEARING (C) 1” 11/2” 2” FOR CALIBRATED INSERT OR FIELD REPAIR KIT HARD CARBON COMPOSITE SLEEVE PICKUP COIL (M ) STANDARD MAGNETIC PICKUP (ISM ) INTRINSICALLY SAFE MAGNETIC PICKUP (CSA/UL) O-RING MATERIAL (V) VITON SPECIAL FEATURES (X) NONE Patented design means one size internal kit fits all three meter sizes (1”, 1½” and 2”). Key Design Features: • • •...

Open the catalog to page 2

All Hoffer Flow Controls catalogs and technical brochures

  1. CAT2

    2 Pages

  2. hogas

    2 Pages

  3. premgas

    4 Pages

  4. cat1

    2 Pages

  5. sy14b

    2 Pages

  6. HIT 2A

    48 Pages

  7. Nova flow

    4 Pages

  8. ACEII

    72 Pages

  9. ICE

    4 Pages

  10. HHP series

    6 Pages

  11. 3A sanitary

    2 Pages

  12. HP

    2 Pages

  13. subsea

    2 Pages

  14. Wingnut

    2 Pages

  15. Nor Mag

    2 Pages

  16. Transi-Flow

    2 Pages

  17. HO series

    2 Pages

  18. LO-CO series

    4 Pages

Archived catalogs