HRT1 Rate Indicator/Totalizer with HART® Communication Protocol Product Bulletin HRT 1-111B The Turbine Flowmeter Company ♦ ♦ ♦ ♦ ♦ ♦ ♦ ♦ ♦ ♦ ♦ HART® Field Communication Protocol. 5 Digit Rate, 8 Digit Totalizer LCD display with configurable decimal point location. 8 Digit, Non-resettable Grand Total display. Pulse Input supports turbine as well as many other pulse generating flowmeters. 4-20mA Analog Output. Up to 20 Point Linearization. Optional Scaled Pulse Output representing an increment of volume for each pulse. Two Optional Alarm Outputs configurable for Rate and Total. Magnetically operated reed switch for Total reset. Internal battery backup. Configuration and Grand Total stored in non-volatile memory. Grand Total saved once per minute. Featuring 5 digits of rate and 8 digits of total, the HRT1 is a loop powered indicator capable of accepting magnetic pickup, DC pulse or switch closure inputs. The HRT1 uses the 4-20mA loop to provide power when this output is used and to provide the HART® communication link. GENERAL Linearization: Up to 20 points. TOTAL DISPLAY: 8 Digits 0.26” high. Resettable. Decimal Points: Configurable for 0, .0, .00 or .000 for rate and total. Total Units: GAL, LIT, FT3, M3, BBL &“blank”. Accuracy: Total: ±1 count, Rate: ±0.01% GRAND TOTAL: INPUTS 8 Digits 0.26” high, Non-resettable. Value stored once per minute in non-volatile memory. Grand Total is displayed for 15 seconds after pressing the > button. Magnetic Pickup: RATE DISPLAY: 5 Digits 0.5” High, Display updates once every two seconds. Rate Units: /SEC, /MIN, /HR, & /DAY. K-factor: The pulses per unit of Total (e.g. pulses/gallon) are configurable in the range 0.001 to 99,999,999. Frequency Range: 0.2 Hz to 5000 Hz. Signal Level: 30 mVp-p to 30Vp-p. Opto-Isolated DC Pulse: Frequency Range: 0 Hz to 5000 Hz. Signal Type: DC Pulse. High (Logic 1): 4 to 30 VDC Low (Logic 0): <1 VDC Min Pulse Width: 0.1 msec
Open the catalog to page 1Contact Closure: Frequency Range: 0 to 5000 Hz. Signal Type: Contact closure, Sig+ Terminal to DC common. Basic Model Number Internal Pull-up: 220 KΩ to +3.3 VDC Series: Reset: A. Enclosure Style: HRT1 - ( A ) - (B) Signal Type: Contact closure, Reset Terminal to DC common. 2 3 (C) - (D) - (E) - (F) - NEMA 4X Enclosure (HRT1 mounted behind clear cover). Min On: 25 msec - Explosion-Proof Housing. Class I, Division I, Groups B, C & D. Class II, Division I, Groups E, F & G. Internal Pull-Up: 100KΩ to +3.3 VDC External Magnet: Activates internal reed switch. 3A ATEX Exd Enclosure. P Panel Mount...
Open the catalog to page 2All Hoffer Flow Controls catalogs and technical brochures
-
CAT2
2 Pages
-
The Hoffer Collection
8 Pages
-
hogas
2 Pages
-
premgas
4 Pages
-
cat1
2 Pages
-
sy14b
2 Pages
-
Subsea flow measurement
2 Pages
-
HIT 2A
48 Pages
-
Batch controller
4 Pages
-
Nova flow
4 Pages
-
ACEII
72 Pages
-
ICE
4 Pages
-
Teflon series
2 Pages
-
HHP series
6 Pages
-
mini flowmeter
4 Pages
-
3A sanitary
2 Pages
-
saddle turbine
2 Pages
-
subsea
2 Pages
-
Tri flo
2 Pages
-
Grooved turbine
2 Pages
-
Wingnut
2 Pages
-
Nor Mag
2 Pages
-
Transi-Flow II
2 Pages
-
Transi-Flow
2 Pages
-
HO series
2 Pages
-
LO-CO series
4 Pages
-
star industrial
2 Pages
Archived catalogs
-
Model ACC39B Power Supply
12 Pages
-
Model 214D-1 Batch Controller
57 Pages
-
Nova-Flow Flow Computer
4 Pages
-
HO Series for Gas
2 Pages
-
HO Series for Liquid
2 Pages