video corpo

HP

HP

HP

Product catalog summary
Overview: The document provides detailed specifications and features of the HRT1 Rate Indicator/Totalizer with HART® Communication Protocol, designed by The Turbine Flowmeter Company. It highlights the device's capabilities in measuring and displaying flow rates and totals, supporting various input types, and offering multiple output options.
Key Specifications:
  • Display: Features a 5-digit rate and 8-digit totalizer LCD display with configurable decimal points. The grand total is non-resettable and stored in non-volatile memory.
  • Inputs: Supports magnetic pickup, DC pulse, and contact closure inputs with a frequency range of 0 to 5000 Hz.
  • Outputs: Includes a 4-20mA analog output, optional scaled pulse output, and two configurable alarm outputs for rate and total.
  • Power: Operates on 8 to 30 VDC with an internal battery backup for up to 6 years.
  • Physical Characteristics: Operates in temperatures from -4°F to 158°F and is housed in a NEMA 4X or explosion-proof enclosure.
Functional Features:
  • Linearization: Supports up to 20-point linearization for accurate flow measurement.
  • Configuration: The device is configurable for various units of measurement and decimal point placements.
  • Communication: Utilizes HART® protocol for field communication, enhancing integration with other systems.
Model Variations: The document outlines different model configurations based on enclosure style, pulse input type, analog output, pulse output, alarms, mounting options, and special features like CE marking for Europe.
Quality Assurance: The product design, manufacture, and testing are certified to ISO 9001 standards, ensuring high quality and reliability.
Important Notes: Specifications are subject to change, and users should verify current specifications with the manufacturer to ensure accuracy.
See more

Catalog excerpts

HP-1

HRT1 Rate Indicator/Totalizer with HART® Communication Protocol Product Bulletin HRT 1-111B The Turbine Flowmeter Company ♦ ♦ ♦ ♦ ♦ ♦ ♦ ♦ ♦ ♦ ♦ HART® Field Communication Protocol. 5 Digit Rate, 8 Digit Totalizer LCD display with configurable decimal point location. 8 Digit, Non-resettable Grand Total display. Pulse Input supports turbine as well as many other pulse generating flowmeters. 4-20mA Analog Output. Up to 20 Point Linearization. Optional Scaled Pulse Output representing an increment of volume for each pulse. Two Optional Alarm Outputs configurable for Rate and Total. Magnetically operated reed switch for Total reset. Internal battery backup. Configuration and Grand Total stored in non-volatile memory. Grand Total saved once per minute. Featuring 5 digits of rate and 8 digits of total, the HRT1 is a loop powered indicator capable of accepting magnetic pickup, DC pulse or switch closure inputs. The HRT1 uses the 4-20mA loop to provide power when this output is used and to provide the HART® communication link. GENERAL Linearization: Up to 20 points. TOTAL DISPLAY: 8 Digits 0.26” high. Resettable. Decimal Points: Configurable for 0, .0, .00 or .000 for rate and total. Total Units: GAL, LIT, FT3, M3, BBL &“blank”. Accuracy: Total: ±1 count, Rate: ±0.01% GRAND TOTAL: INPUTS 8 Digits 0.26” high, Non-resettable. Value stored once per minute in non-volatile memory. Grand Total is displayed for 15 seconds after pressing the > button. Magnetic Pickup: RATE DISPLAY: 5 Digits 0.5” High, Display updates once every two seconds. Rate Units: /SEC, /MIN, /HR, & /DAY. K-factor: The pulses per unit of Total (e.g. pulses/gallon) are configurable in the range 0.001 to 99,999,999. Frequency Range: 0.2 Hz to 5000 Hz. Signal Level: 30 mVp-p to 30Vp-p. Opto-Isolated DC Pulse: Frequency Range: 0 Hz to 5000 Hz. Signal Type: DC Pulse. High (Logic 1): 4 to 30 VDC Low (Logic 0): <1 VDC Min Pulse Width: 0.1 msec

 Open the catalog to page 1
HP-2

Contact Closure: Frequency Range: 0 to 5000 Hz. Signal Type: Contact closure, Sig+ Terminal to DC common. Basic Model Number Internal Pull-up: 220 KΩ to +3.3 VDC Series: Reset: A. Enclosure Style: HRT1 - ( A ) - (B) Signal Type: Contact closure, Reset Terminal to DC common. 2 3 (C) - (D) - (E) - (F) - NEMA 4X Enclosure (HRT1 mounted behind clear cover). Min On: 25 msec - Explosion-Proof Housing. Class I, Division I, Groups B, C & D. Class II, Division I, Groups E, F & G. Internal Pull-Up: 100KΩ to +3.3 VDC External Magnet: Activates internal reed switch. 3A ATEX Exd Enclosure. P Panel Mount Enclosure....

 Open the catalog to page 2

All Hoffer Flow Controls catalogs and technical brochures

  1. CAT2

    2  Pages

  2. hogas

    2  Pages

  3. premgas

    4  Pages

  4. cat1

    2  Pages

  5. sy14b

    2  Pages

  6. HIT 2A

    48  Pages

  7. Nova flow

    4  Pages

  8. ACEII

    72  Pages

  9. ICE

    4  Pages

  10. Teflon series

    2  Pages

  11. HHP series

    6  Pages

  12. 3A sanitary

    2  Pages

  13. subsea

    2  Pages

  14. Tri flo

    2  Pages

  15. Wingnut

    2  Pages

  16. Nor Mag

    2  Pages

  17. Transi-Flow

    2  Pages

  18. HO series

    2  Pages

  19. LO-CO series

    4  Pages

*Prices are pre-tax. They exclude delivery charges and customs duties and do not include additional charges for installation or activation options. Prices are indicative only and may vary by country, with changes to the cost of raw materials and exchange rates.