Power unit Series H4

Power unit Series H4
1 / 12 PagesView full catalog

Power unit Series H4

Product catalog summary
Overview: The document outlines the technical specifications and operational guidelines for the H4 series mini power units by HOERBIGER, designed for single-acting hydraulic cylinders. It covers models H400, H410, and H440, each with unique features and applications.
Specifications:
  • H400: Features an integrated throttle valve for controlling lowering speed, with a compact design due to its cylindrical, oil-resistant powder-coated tank.
  • H410: Includes a 2-way proportional valve for adjusting lifting and lowering speeds, with a similarly coated tank.
  • H440: Offers modular valve assembly compliant with ISO4401-02-01 (NG04) standards, configurable for specific functions like clamping or accumulator operations.
Hydraulic Characteristics:
  • Pump Type: External gear pump with a displacement range of 1.5 - 11.7 l/min.
  • Operating Pressure: Specified in order instructions.
  • Tank Volume: 5 - 11 liters.
  • Hydraulic Medium: Mineral oil as per DIN 51524, with other media available on request.
  • Temperature Range: -10°C to +70°C for pressure media.
  • Viscosity Range: 10 mm²/s to 600 mm²/s, with a starting viscosity of 1600 mm²/s.
Electrical Characteristics:
  • Motor: Three-phase with a nominal capacity of 0.75 - 3.0 kW.
  • Voltage Range: 220-240V/380-420V at 50Hz and 254-280V/440-480V at 60Hz.
  • Protection: IP55 according to DIN40050, with insulation class F as per IEC34-1.
Installation and Mounting:
  • Position: Can be installed horizontally or vertically.
  • Mounting: Utilizes M10 tapped holes at the bell housing.
  • Ambient Temperature: Operates within -10°C to +40°C.
Additional Features:
  • Various assembly modules are available for specific applications.
  • All tanks are oil-resistant powder-coated for durability.
Pump Specifications:
  • Motor power options range from 0.75 kW to 3 kW, with configurations available in 2-pole and 4-pole setups.
  • Motor speeds are approximately 2800 min-1 for 2-pole and 1450 min-1 for 4-pole motors.
  • Pump displacement is measured in cm³ per revolution, with values ranging from 11 to 79 cm³/rev.
Operating Conditions:
  • At 60Hz operation, motor speed, oil flow, and power increase by approximately 20%.
  • The maximum admissible operating pressure varies with the pump model and is specified for operating mode S3-20%.
Performance Data:
  • Flow rates and pressures are provided for different motor speeds and pump displacements, with specific values for 1400 min-1 and 2800 min-1 operations.
  • Performance data is presented in tables, indicating the maximum operating pressure in bar for each pump model and configuration.
Contact Information:
  • HOERBIGER AUTOMATISIERUNGSTECHNIK GmbH, located in Altenstadt, Germany, provides contact details for further inquiries.
See more

Catalog excerpts

Power unit Series H4-1

A1H395_2009.PMD table.main {} tr.row {} td.cell {} div.block {} div.paragraph {} .font0 { font:9.00pt "Franklin Gothic Medium", sans-serif; } .font1 { font:12.00pt "Franklin Gothic Medium", sans-serif; } .font2 { font:21.00pt "Franklin Gothic Medium", sans-serif; } .font3 { font:31.00pt "Franklin Gothic Medium", sans-serif; } Mini-Aggregate Baureihe H4 Mini power units Sries H4 Mini-centrale d'hydraulique Srie H4 HOERBIGER because performance counts

 Open the catalog to page 1
Power unit Series H4-2

A1H395_2009.PMD table.main {} tr.row {} td.cell {} div.block {} div.paragraph {} .font0 { font:7.00pt "Franklin Gothic Medium", sans-serif; } .font1 { font:8.00pt "Franklin Gothic Medium", sans-serif; } .font2 { font:9.00pt "Franklin Gothic Medium", sans-serif; } .font3 { font:11.00pt "Franklin Gothic Medium", sans-serif; } .font4 { font:23.00pt "Franklin Gothic Medium", sans-serif; } HOERBIGER Allgemeines General Gnralit驩s H400 H400 | H400 mit integrierter Steuerung zum Antrieb von einem einfach wirkenden Zylinder (Hub-Senk-Funktion) with integrated control for moving a single acting hydraulic...

 Open the catalog to page 2
Power unit Series H4-3

A1H395_2009.PMD table.main {} tr.row {} td.cell {} div.block {} div.paragraph {} .font0 { font:7.00pt "Franklin Gothic Medium", sans-serif; } .font1 { font:8.00pt "Franklin Gothic Medium", sans-serif; } .font2 { font:9.00pt "Franklin Gothic Medium", sans-serif; } .font3 { font:11.00pt "Franklin Gothic Medium", sans-serif; } .font4 { font:23.00pt "Franklin Gothic Medium", sans-serif; } HOERBIGER Allgemeines General Gnralit驩s H440 | H440 | H440 mit modularem Ventilaufbau (Verket-tung) ISO4401-02-01 (NG04) Verkettungsmodule siehe Katalogblatt A1H507 with modular valve assembly ISO4401-02-01 (NG04)...

 Open the catalog to page 3
Power unit Series H4-4

A1H395_2009.PMD table.main {} tr.row {} td.cell {} div.block {} div.paragraph {} .font0 { font:6.00pt "Franklin Gothic Medium", sans-serif; } .font1 { font:7.00pt "Franklin Gothic Medium", sans-serif; } .font2 { font:8.00pt "Franklin Gothic Medium", sans-serif; } .font3 { font:11.00pt "Franklin Gothic Medium", sans-serif; } .font4 { font:13.00pt "Franklin Gothic Medium", sans-serif; } .font5 { font:22.00pt "Franklin Gothic Medium", sans-serif; } .font6 { font:23.00pt "Franklin Gothic Medium", sans-serif; } c!t> HOERBIGER Miniaggregat Baureihe H4 1,5-11,7 l/min Mini power unit series H4 1,5-11,7...

 Open the catalog to page 4
Power unit Series H4-5

A1H395_2009.PMD table.main {} tr.row {} td.cell {} div.block {} div.paragraph {} .font0 { font:6.00pt "Arial", sans-serif; } .font1 { font:7.00pt "Arial", sans-serif; } .font2 { font:11.00pt "Arial", sans-serif; } .font3 { font:17.00pt "Arial", sans-serif; } .font4 { font:18.00pt "Arial", sans-serif; } .font5 { font:20.00pt "Arial", sans-serif; } Aggregat H440_ ■ Auf das Aggregat H440 kann mit RohranschluBplatten, Zwischenplattenaufbau oder mit einzelnen Verkettungs-platten aufgebaut werden. ■ Die Verbrauchereran-schlusse auf dem Pumpen trger und auf den Verket-tungsplatten befinden sich auf...

 Open the catalog to page 5
Power unit Series H4-6

A1H395_2009.PMD table.main {} tr.row {} td.cell {} div.block {} div.paragraph {} .font0 { font:5.30pt "Arial", sans-serif; } .font1 { font:6.00pt "Arial", sans-serif; } .font2 { font:7.00pt "Arial", sans-serif; } .font3 { font:9.00pt "Arial", sans-serif; } .font4 { font:11.00pt "Arial", sans-serif; } .font5 { font:20.00pt "Arial", sans-serif; } HOERBIGER KenngrBen Characteristics Caractristiques Allgemein Einbaulage horizontal oder vertikal Befestigung Gewindebohrungen M10 am Pumpentr䩢ger Umgebungstemperaturbereich min -10 °C, max +40 °C Korrosionsschutz Motor: lackiert n. RAL6000 bzw. Aluminium...

 Open the catalog to page 6
Power unit Series H4-7

A1H395_2009.PMD table.main {} tr.row {} td.cell {} div.block {} div.paragraph {} .font0 { font:3.60pt "Arial", sans-serif; } .font1 { font:4.00pt "Arial", sans-serif; } .font2 { font:5.00pt "Arial", sans-serif; } .font3 { font:6.00pt "Arial", sans-serif; } .font4 { font:7.00pt "Arial", sans-serif; } .font5 { font:11.00pt "Arial", sans-serif; } .font6 { font:13.00pt "Arial", sans-serif; } .font7 { font:15.00pt "Arial", sans-serif; } .font8 { font:20.00pt "Arial", sans-serif; } .font9 { font:25.00pt "Arial", sans-serif; } .font10 { font:4.00pt "Microsoft Sans Serif", sans-serif; } Abmessungen H400...

 Open the catalog to page 7
Power unit Series H4-8

A1H395_2009.PMD table.main {} tr.row {} td.cell {} div.block {} div.paragraph {} .font0 { font:5.00pt "Arial", sans-serif; } .font1 { font:6.00pt "Arial", sans-serif; } .font2 { font:7.00pt "Arial", sans-serif; } .font3 { font:8.00pt "Arial", sans-serif; } .font4 { font:10.00pt "Arial", sans-serif; } .font5 { font:11.00pt "Arial", sans-serif; } .font6 { font:20.00pt "Arial", sans-serif; } .font7 { font:6.00pt "Lucida Sans Unicode", sans-serif; } .font8 { font:7.00pt "Trebuchet MS", sans-serif; } Abmessungen H410 [mm] Dimensions H410 [mm] HOERBIGER Dimensions H410 [mm] 168 D T / L = \ r Tank /...

 Open the catalog to page 8
Power unit Series H4-9

A1H395_2009.PMD table.main {} tr.row {} td.cell {} div.block {} div.paragraph {} .font0 { font:4.00pt "Arial", sans-serif; } .font1 { font:5.00pt "Arial", sans-serif; } .font2 { font:6.00pt "Arial", sans-serif; } .font3 { font:7.00pt "Arial", sans-serif; } .font4 { font:11.00pt "Arial", sans-serif; } .font5 { font:20.00pt "Arial", sans-serif; } HOERBIGER Abmessungen H440 [mm] Dimensions H440 [mm] Dimensions H440 [mm] 23. 43 L1()11@);,(a_ Anschlu&platte Subplate ^laque de raccordement ISO4401-02-01-0-94, NG04 | Tank / Rservoir Tankvolumen Nutzvolumen total volume effective volume volumetotal volumeutile...

 Open the catalog to page 9
Power unit Series H4-10

A1H395_2009.PMD table.main {} tr.row {} td.cell {} div.block {} div.paragraph {} .font0 { font:6.00pt "Arial", sans-serif; } .font1 { font:7.00pt "Arial", sans-serif; } .font2 { font:9.00pt "Arial", sans-serif; } .font3 { font:10.00pt "Arial", sans-serif; } .font4 { font:11.00pt "Arial", sans-serif; } .font5 { font:15.00pt "Arial", sans-serif; } .font6 { font:20.00pt "Arial", sans-serif; } c!> HOERBIGER Bestellangaben H400 / H410 Serienkennzeichnung siehe Basisinformationen Typenbezeichnung Type code Code d'identification Order instructions H400 / H410 Production code see basic informations H410...

 Open the catalog to page 10

All HOERBIGER Automatisierungstechnik GmbH catalogs and technical brochures

  1. tecno basic

    9  Pages

  2. tecno easy

    6  Pages

  3. tecno plus

    8  Pages

  4. CP valve

    8  Pages

  5. XperLUBE

    8  Pages

  6. Test Stands

    8  Pages

  7. HR080 series

    12  Pages

  8. H650

    12  Pages

  9. H4

    12  Pages

  10. H3

    8  Pages

  11. PLM

    8  Pages

  12. AKB

    20  Pages

  13. AVB

    22  Pages

  14. PVM

    23  Pages

  15. AMB

    24  Pages

  16. Control units

    4  Pages

  17. Cylinder

    12  Pages

  18. Subplates

    8  Pages

  19. Modular valves

    68  Pages

*Prices are pre-tax. They exclude delivery charges and customs duties and do not include additional charges for installation or activation options. Prices are indicative only and may vary by country, with changes to the cost of raw materials and exchange rates.