Vortex Flow Sensors VA Di
6Pages

{{requestButtons}}

Catalog excerpts

Vortex Flow Sensors VA Di - 1

Vortex Flow Sensors VA Di ________________________________________________________________________________________________ Vortex Flow Sensors VA Di also suitable for applications in condensation and particle laden gases Measurable variable  actual flow rate  standard velocity standard flow rate (in combination with pressure and temperature sensors) Design  measuring tube Functional principle  vortex meter for measuring flow rate and volume  ultrasonic measurement of the vortex shedding Advantages  low starting value  high measuring dynamics (up to 1 : 100)  no moving parts  maximum fatigue strength  corrosion resistant  operates to a large extent irrespective of gas composition  low pressure drop  easy adjustment to process parameter Medium  primarily single-phase gas mixtures, e.g. air, nitrogen, oxygen, methane, natural gas, flare gas, ammonia, argon, carbon monoxide, superheated steam, combustion exhaust gas, biogas, sewage gas. Particles, condensation, humidity in the gas  charges in the gas caused by particles such as dust and fibres do not affect the measurement, as long as abrasion and agglomeration do not occur on the sensor Other gases or gas mixtureson request  measurement uncertainty Range and examples of application  flow measurement, for example, of air, exhaust gas, process gas, bio and sewage gas, engine intake air, exhaust emissions, gases laden with particles, dust and fibres, superheated steam remains unaffected by a relative gas humidity of less than 100 % and a slight accumulation o

Open the catalog to page 1
Vortex Flow Sensors VA Di - 2

Vortex Flow Sensors VA Di ________________________________________________________________________________________________ Model designation / order code (example) VA Di 40 G E 40 m/s (1) (2) (3) (4) Basic types Type with integrated transducer UVA (output 4-20 mA or 0-10 V) art. no. B015/016 (1) Dimensions tube flange inside Ø outside Ø Di D [mm] [mm] without integrated transducer UVA (output v/VA or v/VA-Ex) (2) Medium Gases (3) Materials in contact with the medium design ... GE ... ... GT ... ... GH ... ... GL ... material stainless steel 1.4404, 1.4571, 1.4581, ceramics titanium 3.7035...

Open the catalog to page 2
Vortex Flow Sensors VA Di - 3

Vortex Flow Sensors VA Di ________________________________________________________________________________________________ (4) Measuring range Di [mm] 40 50 80 100 Calibration For each sensor, one of the two calibration options listed below must be selected. calibration option ISO calibration (inclusive calibration certificate) calibration medium air, adjustment in sensor measuring range up to max. 1600 m³/h, 6 calibration values in the scaled measuring range DAkkS calibration (inclusive calibration certificate) calibration medium air, adjustment in sensor measuring range up to max. 1600...

Open the catalog to page 3
Vortex Flow Sensors VA Di - 4

Vortex Flow Sensors VA Di ________________________________________________________________________________________________ Mounting attitude any to ensure that the sensor remains operative in horizontal pipeline even with moderate condensation, sensors VA Di 40, VA Di 50, VA Di 80 and VA Di 100 should be installed with the connection housing pointing sideways. In vertical pipeline the attitude for all sensors VA Di ... - also in case of moderate condensation - can be chosen freely. Options (A) ... (C) sealing material (A) Option (A) material FKM (standard) silicone KALREZ working...

Open the catalog to page 4
Vortex Flow Sensors VA Di - 5

Vortex Flow Sensors VA Di ________________________________________________________________________________________________ Output v/VA, v/VA-Ex, 4-20 mA or 0-10 V output sensor v/VA Höntzsch evaluation unit ** with v/VA input is necessary for signal interpretation output sensor v/VA-Ex, Höntzsch evaluation unit with intrinsically safe input v/VA-Ex or (sensor with Option (C) an evaluation unit** with input v/VA together with a series connection see above) isolation/supply unit LDX2 is necessary for signal interpretation output 4-20mA or 0-10V with transducer UVA integrated in the connection...

Open the catalog to page 5
Vortex Flow Sensors VA Di - 6

Vortex Flow Sensors VA Di ________________________________________________________________________________________________ Accessories (optional) (cont.) description for configuring transducers UFA and UVA via RS232 interface, PC connection cable RJ22 / sub-D 9-pin additional requirement PC connection cable for configuring transducers UFA and UVA RJ22 / sub-D 9-pin*° in LDG16 or AS102 housing via RS232 interface together with UCOM software; transducer connection: RJ22 PC connection: sub-D 9-pin Interface converter*° for connecting PC to USB port and USB / RS232 Höntzsch programming adapter...

Open the catalog to page 6

All Höntzsch GmbH & Co KG catalogs and technical brochures

  1. Calibration

    7 Pages

  2. U116_ZS_D

    12 Pages