Catalog excerpts
———— Description —–—— —––—– Specifications —–—— ––— The Source-Sinks of the NL series are fourSourcefourquadrant power supply units designed for practical use within laboratories as well as in the fields of production and quality assurance. assurance Power range: Voltages: Currents: 100W ... 3,520W Unipolar: -1V ... +100V Bipolar: ±8V ... ±44V ±2A ...±320A Operating modes: Limitations: temperatureCurrent and temperaturecontrolled fan cooling Analog interface: SourceThe unipolar version of the Source-Sink fourfeatures a restricted four-quadrant operating mode and allows a negative output...
Open the catalog to page 2——————–————– —————————————–————–— Functions ———————-————— Operating modes The NL Source-Sinks are capable of operating in constant voltage or constant current mode. When a device is operating in voltage mode, two current limitations (source current and sink current) can be set independently of each other. In current mode an upper and a lower voltage limitation can be set. SourceSource-Sink mode Depending on the output setting and the characteristics of the item being tested, the device automatically determines whether it will operate as a source or as a sink. Change from source to sink mode...
Open the catalog to page 4———–————– ————– ——————– ———–————–———— Functions ————–—–——————– Remote control All of the Source-Sink’s functions can be remote controlled by the analog I/O connector provided as standard. The operating mode, output on/off function, as well as the settings for the control rate can be configured on the basis of logic levels. A version which is galvanically isolated from the output is optionally available (Option NL06). Terminals All terminals are arranged at the rear of the device. The current terminals are in the form of 4mm terminals posts or solid copper bars w ith s c re w . 4 mm...
Open the catalog to page 5————–——–——–———– ————–———————– ————–——–——–———– Options ————–———————– GPIB interface extension1) (Option ZS03) Castors 1) (Option ZS09) The ZS03 option upgrades the device by adding a GPIB interface. The board is simply plugged into the free interface slot. GPIB cable is not included. Castors can be fitted to heavier devices for easier transportation. As a result, a 19” cabinet is often not required. This option is Castors available for devices with at least 5HUs and is suitable for hard floors only. Galvanically isolated analog interface 1) (Option NL06) Temperature Interface Board 1)...
Open the catalog to page 6Software Tools Data acquisition tool (Option NL13)1' The Data acquisition tool extends the range of functions • Fast data acquisition with memory, synchronized to Fast data acquisition (switchable) Data acquisition with variable reading rate synchronized with the programmed waveform. Simultaneous reading of voltage and The following software tools and drivers are included along with the interfaces: Control Tool (versatile control program) This tool allows to control a single unit • Device settings • Measurement data acquisition with numerical display • Selection of trigger source •...
Open the catalog to page 7Software Tools Battery Test Tool Determining capacity Switch-off criteria Dynamic test The battery test tool makes it possible to test an extremely wide range of energy storage devices using • Various storage device types and their limit values • There are various monitoring criteria for ending the charging or discharging phases : - External event (Option ZS07 required)2' A predefined waveform can be applied to the DUT in order to test it for specific requirements. The most important current testing information is A log file in order to document the test procedure. is produced. The time...
Open the catalog to page 8———– —–—––—–—–—– Type Overview - Unipolar Devices ———–—— ––— NL1V10C20 NL1V20C10 NL1V30C8 NL1V42C6 NL1V80C3 NL1V100C2 Terminals 2) Power consumption Mains supply W x H x D (mm) 3) Weight Case 4) -1 V ... +10 V ±20 A 200 W 200 µs 200 µs PK4 426 VA 115/230 VAC 483 x 88 x 520 13 kg 19“-2 HU -1 V ... +20 V ±10 A 200 W 200 µs 200 µs PK4 380 VA 115/230 VAC 483 x 88 x 520 13 kg 19“-2 HU -1 V ... +30 V ±8 A 240 W 200 µs 200 µs PK4 380 VA 115/230 VAC 483 x 88 x 520 13 kg 19“-2 HU -1 V ... +42 V ±6 A 252 W 200 µs 200 µs PK4 414 VA 115/230 VAC 483 x 88 x 520 13 kg 19“-2 HU -1 V ... +80 V ±3 A 240 W...
Open the catalog to page 9———–———– —–—––——–—– Type Overview - Bipolar Devices ———–———– ––——– —— NL10V10C10 Voltage Current Power Rise-/fall time 1) Current Voltage Terminals 2) Power consumption Mains supply W x H x D (mm) 3) Weight Case 4) NL20V20C5 NL30V30C3.5 NL50V50C2 ±10 V ±10 A 100 W 200 µs 200 µs PK4 270 VA 115/230 VAC 483 x 88 x 520 13 kg 19“-2 HU Model (Order-No.) ±20 V ±5 A 100 W 200 µs 200 µs PK4 250 VA 115/230 VAC 483 x 88 x 520 13 kg 19“-2 HU ±30 V ±3,5 A 105 W 200 µs 200 µs PK4 235 VA 115/230 VAC 483 x 88 x 520 13 kg 19“-2 HU ±50 V ±2 A 100 W 200 µs 200 µs PK4 220 VA 115/230 VAC 483 x 88 x 520 13 kg...
Open the catalog to page 10All Höcherl & Hackl catalogs and technical brochures
-
PMLA Series
10 Pages
-
ZS Series
12 Pages
-
NL Series
11 Pages
-
Brochure PMLA
14 Pages
-
Brochure ERI Series
12 Pages
-
PLA Series Brochure
16 Pages
-
ZS/ZSLC/ZSLV Series
23 Pages
-
PMLI Series
6 Pages
-
PL Series
5 Pages
-
Main catalogue
76 Pages
-
Electronic Loads, PLI Series
5 Pages
-
PMLI Multiload
4 Pages
-
Power Supply Control
4 Pages
-
PL Electronic Loads
4 Pages
-
ZSAC Electronic AC Loads
12 Pages
-
H&H Product Overview
4 Pages
Archived catalogs
-
NL SERIES
11 Pages