Product catalog summary
Overview: The document outlines the specifications and functionalities of the NL series Source-Sinks, which are versatile four-quadrant power supply units. These units are designed for laboratory, production, and quality assurance applications, functioning as both voltage/current sources and current sinks. They offer power ratings from 100W to 3,520W, with customization available for higher power needs.
Specifications: The NL series supports a voltage range up to ±50V (bipolar) and up to 100V (unipolar), with currents reaching 320A. They operate in constant current (CC) and constant voltage (CV) modes, with rapid switching capabilities between source and sink modes. Standard interfaces include RS232 and USB, with optional GPIB and Smart-LAN interfaces.
Operating Modes: These devices can function in two-quadrant or four-quadrant modes, allowing for current supply or consumption in reverse direction. The unipolar version supports a limited four-quadrant mode with a negative output voltage up to -1V.
Applications: The NL series is ideal for testing batteries, accumulators, generators, solar panels, electrical drive systems, battery chargers, power supplies, and electrical components. It is also used for load simulations, dynamic tests, lifetime tests, and battery simulations.
Interfaces and Control: Equipped with RS232 and USB interfaces as standard, with options for GPIB and Smart-LAN, these devices can be remotely controlled via an analog I/O connector, with options for galvanic isolation. They support fast data acquisition and dynamic testing through software tools.
Cooling and Housing: The devices are air-cooled with fans that adjust based on power and current to minimize noise. They are housed in robust 19" rack mount cases, suitable for bench-top use or cabinet installation, with optional castors for mobility.
Options and Accessories: Available options include relay contacts, logic inputs, fast data acquisition, galvanically isolated interfaces, and factory calibration certificates. Additional features like a temperature interface board and power I/O board can be retrofitted.
Technical Data: Devices are available in various sizes, with dimensions ranging from 2HU to 14HU and weights from 13 kg to 105 kg. Voltage ranges from ±8V to ±80V and current from ±2A to ±320A. Power ratings vary from 100W to 3,520W, with a consistent rise/fall time of 200 µs for both current and voltage. Power consumption varies by model, with mains supply typically at 115/230 VAC or 230/400 VAC with a 16A requirement.
Accuracy and Resolution: Display accuracy is ±0.1% for voltage and ±0.2% for current, with 16-bit resolution for settings and 18-bit for standard measurement readings.
Operating Conditions and Protection: Devices operate between 5°C and 40°C, with derating above 21°C. Protection features include current and voltage limitation, over-temperature deactivation, and emergency shutdown. Up to three devices can be operated in a master-slave configuration.
Standards and Compliance: Devices comply with DIN EN 61010-1 for electric safety and DIN EN 61326-1 for EMC, among other standards.
Additional Notes: For 19" rack mounting, slide bars are recommended due to device weight. Specific models, such as the NL06, offer extended voltage ranges.
See more

Catalog excerpts

NL Source-Sink-2

———— Description —–—— —––—– Specifications —–—— ––— The Source-Sinks of the NL series are fourSourcefourquadrant power supply units designed for practical use within laboratories as well as in the fields of production and quality assurance. assurance Power range: Voltages: Currents: 100W ... 3,520W Unipolar: -1V ... +100V Bipolar: ±8V ... ±44V ±2A ...±320A Operating modes: Limitations: temperatureCurrent and temperaturecontrolled fan cooling Analog interface: SourceThe unipolar version of the Source-Sink fourfeatures a restricted four-quadrant operating mode and allows a negative output voltage...

 Open the catalog to page 2
NL Source-Sink-4

——————–————– —————————————–————–— Functions ———————-————— Operating modes The NL Source-Sinks are capable of operating in constant voltage or constant current mode. When a device is operating in voltage mode, two current limitations (source current and sink current) can be set independently of each other. In current mode an upper and a lower voltage limitation can be set. SourceSource-Sink mode Depending on the output setting and the characteristics of the item being tested, the device automatically determines whether it will operate as a source or as a sink. Change from source to sink mode occurs...

 Open the catalog to page 4
NL Source-Sink-5

———–————– ————– ——————– ———–————–———— Functions ————–—–——————– Remote control All of the Source-Sink’s functions can be remote controlled by the analog I/O connector provided as standard. The operating mode, output on/off function, as well as the settings for the control rate can be configured on the basis of logic levels. A version which is galvanically isolated from the output is optionally available (Option NL06). Terminals All terminals are arranged at the rear of the device. The current terminals are in the form of 4mm terminals posts or solid copper bars w ith s c re w . 4 mm connectors,...

 Open the catalog to page 5
NL Source-Sink-6

————–——–——–———– ————–———————– ————–——–——–———– Options ————–———————– GPIB interface extension1) (Option ZS03) Castors 1) (Option ZS09) The ZS03 option upgrades the device by adding a GPIB interface. The board is simply plugged into the free interface slot. GPIB cable is not included. Castors can be fitted to heavier devices for easier transportation. As a result, a 19” cabinet is often not required. This option is Castors available for devices with at least 5HUs and is suitable for hard floors only. Galvanically isolated analog interface 1) (Option NL06) Temperature Interface Board 1) (Option...

 Open the catalog to page 6
NL Source-Sink-7

Software Tools Data acquisition tool (Option NL13)1' The Data acquisition tool extends the range of functions • Fast data acquisition with memory, synchronized to Fast data acquisition (switchable) Data acquisition with variable reading rate synchronized with the programmed waveform. Simultaneous reading of voltage and The following software tools and drivers are included along with the interfaces: Control Tool (versatile control program) This tool allows to control a single unit • Device settings • Measurement data acquisition with numerical display • Selection of trigger source • Activating...

 Open the catalog to page 7
NL Source-Sink-8

Software Tools Battery Test Tool Determining capacity Switch-off criteria Dynamic test The battery test tool makes it possible to test an extremely wide range of energy storage devices using • Various storage device types and their limit values • There are various monitoring criteria for ending the charging or discharging phases : - External event (Option ZS07 required)2' A predefined waveform can be applied to the DUT in order to test it for specific requirements. The most important current testing information is A log file in order to document the test procedure. is produced. The time resolution...

 Open the catalog to page 8
NL Source-Sink-9

———– —–—––—–—–—– Type Overview - Unipolar Devices ———–—— ––— NL1V10C20 NL1V20C10 NL1V30C8 NL1V42C6 NL1V80C3 NL1V100C2 Terminals 2) Power consumption Mains supply W x H x D (mm) 3) Weight Case 4) -1 V ... +10 V ±20 A 200 W 200 µs 200 µs PK4 426 VA 115/230 VAC 483 x 88 x 520 13 kg 19“-2 HU -1 V ... +20 V ±10 A 200 W 200 µs 200 µs PK4 380 VA 115/230 VAC 483 x 88 x 520 13 kg 19“-2 HU -1 V ... +30 V ±8 A 240 W 200 µs 200 µs PK4 380 VA 115/230 VAC 483 x 88 x 520 13 kg 19“-2 HU -1 V ... +42 V ±6 A 252 W 200 µs 200 µs PK4 414 VA 115/230 VAC 483 x 88 x 520 13 kg 19“-2 HU -1 V ... +80 V ±3 A 240 W 200...

 Open the catalog to page 9
NL Source-Sink-10

———–———– —–—––——–—– Type Overview - Bipolar Devices ———–———– ––——– —— NL10V10C10 Voltage Current Power Rise-/fall time 1) Current Voltage Terminals 2) Power consumption Mains supply W x H x D (mm) 3) Weight Case 4) NL20V20C5 NL30V30C3.5 NL50V50C2 ±10 V ±10 A 100 W 200 µs 200 µs PK4 270 VA 115/230 VAC 483 x 88 x 520 13 kg 19“-2 HU Model (Order-No.) ±20 V ±5 A 100 W 200 µs 200 µs PK4 250 VA 115/230 VAC 483 x 88 x 520 13 kg 19“-2 HU ±30 V ±3,5 A 105 W 200 µs 200 µs PK4 235 VA 115/230 VAC 483 x 88 x 520 13 kg 19“-2 HU ±50 V ±2 A 100 W 200 µs 200 µs PK4 220 VA 115/230 VAC 483 x 88 x 520 13 kg 19“-2...