NL SERIES
11Pages

{{requestButtons}}

Catalog excerpts

NL SERIES - 2

Interface overview RS-232 USB GPIB System bus Analog Analog isolated ZSLV PMLI 2-quadrant or 4-quadrant versions Source-sink function Rapid control time Current and voltage mode USB + RS-232 interface Programmable waveform SCPI programming with measurement function Software tools for battery testing Adjustable limitations Analog measurement outputs for voltage and current Analog control inputs Operating Modes Source-sink Mode Depending on the preset output Devices for two-quadrant mode stant current mode. the connected test unit, the can supply or receive current In voltage mode there are...

Open the catalog to page 2
NL SERIES - 3

For voltage and current there Separate installation kits are not needed for 19“ rack installation. Operating mode selection, out- signals follow the curve trajec- from the output is optionally keep the operating noise low, Covers are available for outputs 3 Analog Control Inputs Depending on the selected oper- current-dependently controlled. or output current can be preset rack design and can also be table-top device. further analog inputs available to limit the voltage or current. From 5 height units there are retractable handles on the top of the device. for dangerous contact voltages ....

Open the catalog to page 3
NL SERIES - 4

Hardware Expansions GPIB Interface Expansion Electrically Isolated Analog With the ZS03 option the device Data is sent via the LAN card to the serial interface of the unit. card can be replaced with an (Supplied without GPIB cable.) Interface the standard Analog I/O Simply insert the card. vices. 8 relay contacts (N/O 125 panded to control external de- between the negative load input isolated version. All measurement In the case of potential differences and control signals are transmitted via isolation amplifiers and voltage is 500 V DC with respect isolated from the load input. The...

Open the catalog to page 4
NL SERIES - 5

Factory Calibration Certifi- A Factory Calibration Certificate This calibration certificate docu- ments the traceability to nation- physical unit in accordance with the international device system interval is 1 year. We would be happy to calibrate your devices FortOfy Co.broW. CfftlKOtt Execution Mode RecallWF SaveWF iDrawGraphl

Open the catalog to page 5
NL SERIES - 6

Software Tools Battery Test Tool • Capacity determination • Cut-off criteria • Dynamic test The Battery Test Tool enables the testing of the most diverse energy storage units to be test- Different storage types and their technical data can be charging phases there are dif- ferent monitoring criteria. • External event apply a predefined waveform. The most important current test justed from 300 ms onwards. text file for further processing, • Test conditions • Switch-off criteria Discharge Voltage Limits per Cell Min Value [V] Ref value [V] Max Value [V] Charge Voltage limits per Cel Min Value...

Open the catalog to page 6
NL SERIES - 7

Type Overview of Unipolar Devices Measured at short-circuited output terminals (current) and open output terminals (voltage). Tolerance ±20 % Flat copper rail 25x10 mm with 4 mm hole and M10 and M12 screw fastenings 4mm pole terminals M8 screw fitting Pole terminals for forked cable lug and 4mm jack 19“ rack installation, approx. 100 mm should be added to installation depth for rear cable connections. The weight of the devices means that sliding rails must be used for 19“rack installation. Application Notes Model (order number) Voltage Current Power Rise/ Current fall time 1) Voltage...

Open the catalog to page 7
NL SERIES - 8

ZSLC ZSLV PMLI ZSAC Application Notes Type Overview of Bipolar Devices NL10V10C10 Model (order number) Voltage Current Power Current Rise/ fall time 1) Voltage Connection 2) Power consumption Mains supply W x H x D (mm) 3) Weight Housing 4) Model (order number) Voltage Current Power Current Rise/ fall time 1) Voltage Connection 2) Power consumption Mains supply W x H x D (mm) 3) Weight Housing 4) Model (order number) Voltage Current Power Current Rise/ fall time 1) Voltage Connection 2) Power consumption Mains supply W x H x D (mm) 3) Weight Housing 4) 1) Measured at short-circuited output...

Open the catalog to page 8
NL SERIES - 9

NL device with FK25 connections Dimension of terminals when using protective cover In the case of 19" rack systems, sliding rails are needed due to weight.

Open the catalog to page 9
NL SERIES - 10

Technical Data Accuracy of measurement of the setting value of the measured value (real value) ±0.2 % Voltage protection Current protection Sampling rate (not synchronized) Accuracy of measurement with Data Acquisition Tool (Option NL13), read out via data interface of the measured value (real value) Voltage Sampling rate (programmable) ZSLV PMLI minimal 200 µs (in memory) triggerable Operating temperature Color: Front panel side panels, top Current protection * (upper and lower) Measuring instrument category Voltage protection * (upper and lower) RAL7032 (pebble grey) RAL7037 (stone grey)...

Open the catalog to page 10
NL SERIES - 11

Hoecherl & Hackl GmbH Industriestr. 13 94357 Konzell Germany Tel.: +49 9963/94301- 0 Fax.: +49 9963/94301-84 E-Mail: office@hoecherl-hackl.com http://www.hoecherl-hackl.com

Open the catalog to page 11

All Höcherl & Hackl catalogs and technical brochures

  1. PMLA Series

    10 Pages

  2. ZS Series

    12 Pages

  3. NL Series

    11 Pages

  4. Brochure PMLA

    14 Pages

  5. PMLI Series

    6 Pages

  6. PL Series

    5 Pages

  7. Main catalogue

    76 Pages

  8. NL Source-Sink

    12 Pages