Electronic AC Loads, ZSAC Series
9Pages

{{requestButtons}}

Catalog excerpts

Electronic AC Loads, ZSAC Series - 2

ZSLV PMLI ZSAC Electronic AC Loads, ZSAC Series Interface overview RS-232 USB GPIB LAN System bus Analog Analog isolated X Standard As single phase version and for 3-phase Star and delta connection possible Input voltages up to 440 V Power 400 W ... 21,000 W Current and resistance mode Programmable waveform Operating Modes Application Notes The AC current loads of the ZSAC series feature constant current and resistance operating modes. In AC mode the current is set as sinusoidal. In resistance mode the height and waveform of the current depends on the input voltage. Voltage Types Phase...

Open the catalog to page 2
Electronic AC Loads, ZSAC Series - 3

ZSLV current-dependently controlled. following interfaces: designed Mechanics design and can also be used as vices can be fitted with the Analog Control Input control inputs can be operated with TTL levels and 24 V from The interface cards are remova- trolled remotely via the stand- keep the operating noise low, System interface fiber optic From 5 height units there are DC. Analog Measurement Outputs There are 0 ... 7 V analog Remote Control age, current and power available. The outputs are electrically isolated from the load input. retractable handles on the top of the device. 1) Optional...

Open the catalog to page 3
Electronic AC Loads, ZSAC Series - 4

Data Interfaces Resolution Accuracy 16 Bits see technical data Measurement function Resolution Sampling rate Accuracy 18 Bits ca. 300 ms for V+I not synchronized see technical data Measured data memory Waveform memory Resolution Functions 512 points/period programmable waveforms Crest factor Harmonics (3rd to 15th) Phase control Phase shift * Load profile generator Extended function range Steps Pulse duration Ramp time Cycling rate max. 50 200 µs … 2,000 s 0 … 2,000 s once, n times, continuous when using an optional data SCPI programming Settings with 16 Bit resolution Measurement function...

Open the catalog to page 4
Electronic AC Loads, ZSAC Series - 5

Setting Up Three-Phase Systems Fiber Optic System Interface (Option ZS05) (ZS05-M for Master devices, ZS05-S for Slave devices) The fiber optic connection is used to control three phase systems. Including 5m optical cable. Op- Wiring of three-phase systems Wiring of Three-Phase Systems Load 1+ZS01+ZS05-M, Load 2+ZS05-S Load 3+ZS05-S Order example for a three-phase system: Master with RS-232 interface Slaves connected to the master with fiber optic sytem interface: Depending on the rated voltage, Phase-Phase, Phase-Neutral or mixed devices can be wired. The control can be either individual,...

Open the catalog to page 5
Electronic AC Loads, ZSAC Series - 6

Software Tools standard with the interfaces: Load Control Individual devices and multi- The range of functions includes PC device set-up, data logging with graphical display and sav- ing data for other programs. Data Acquisition As well as device control, meas- ured data can be logged and The following measured values Time, voltage, current. Waveform Editor The Waveform Editor permits load profiles in the form of straight sections. The load tra- jectory is displayed on entry. Phase Control Phase-controlled currents with Basic Communication Tool The Basic Communication Tool mands for test...

Open the catalog to page 6
Electronic AC Loads, ZSAC Series - 7

Current Power Resistance Connection Power consumption Noise max. Weight Housing Model (order number Voltage Model (order number Voltage Power Resistance Connection Power consumption Noise max. Weight Housing Current Power Resistance Connection Power consumption Noise max. Weight Housing Model (order number Voltage Power Resistance Connection Power consumption Noise max. Weight Housing Power Resistance Connection Power consumption Noise max. Weight Housing Application Notes SB4: 4mm safety socket SB6: 6mm safety socket (also fits 4mm jack) Measured on the front panel from distance 1m Model...

Open the catalog to page 7
Electronic AC Loads, ZSAC Series - 8

Technical Data ZSAC, ZSACRV Series of the setting value Current Accuracy of manual setting, no preset function Accuracy of manual setting via preset function ±0.5 % of current range ±1 % of current range ZSLV PMLI Acessories Application Notes ±0.5 % of current range ±1 % of current range of the measured value (real value) Accuracy of display of the measured value (real value) Accuracy of reading, read out via data interface Sampling rate External control functions Accuracy analog control 0 ... 3.5 V / 0 ... 7 V for current Load on - off Trigger input and output Remote shut down 2 currents...

Open the catalog to page 8
Electronic AC Loads, ZSAC Series - 9

Hoecherl & Hackl GmbH Industriestr. 13 94357 Konzell Germany Tel.: +49 9963/94301- 0 Fax.: +49 9963/94301-84 E-Mail: office@hoecherl-hackl.com http://www.hoecherl-hackl.com

Open the catalog to page 9

All Höcherl & Hackl catalogs and technical brochures

  1. PMLA Series

    10 Pages

  2. ZS Series

    12 Pages

  3. NL Series

    11 Pages

  4. Brochure PMLA

    14 Pages

  5. PMLI Series

    6 Pages

  6. PL Series

    5 Pages

  7. Main catalogue

    76 Pages

  8. NL Source-Sink

    12 Pages

Archived catalogs

  1. NL SERIES

    11 Pages