Electronic Multi-Channel Load PMLA

Open the catalog to page 1
Brochure PMLA - 2

Power Distribution Source-Sink AC & DC Multi-Channel Mulit-Channel, GUI Energy Recycling Multi-Range High Power Low Power H&H Multi-Channel Loads, PMLA Series LAN Interface Overview Slave X Standard O Option / not available X Standard O Option / not available • Configurable multi-channel load • Up to 12 channels in 19" - 2 HU • Channel expansion via Slave devices • Maximum 72 channels per system • Tailored configurations possible with modules in 4 voltage and 4 power classes • 150 W - 300 W - 450 W - 600 W modules • Voltages 40 V - 60 V - 120 V - 240 V • Currents from 1...

Open the catalog to page 2
Brochure PMLA - 3

PMLA Series Applications • Calibration of driver outputs • Consumer test of electrical systems Test of: • Batteries and accumulators • Cables • Absorbers • DC/DC converters • Electronic assemblies • Electronic fuses and cut-off • Fuse boxes • ECUs • Power distributors Trigger Model By the trigger model all channels can synchronously be switched on or a programmed load profile can be started. Cooler and Load Modules Up to three cooling units are installed at each device. One cooling unit accomodates one to four load modules, depending on type. Terminals The load terminals are provided at...

Open the catalog to page 3
Brochure PMLA - 4

Power Distribution Source-Sink AC & DC Multi-Channel Mulit-Channel, GUI Energy Recycling Multi-Range High Power Low Power H&H Model Overview PMLA Series Devices and Interfaces are available in the following versions: PMLA-M Master device with USB, RS-232 and LAN interface incl. PMLA system interface for connecting up to 5 slave devices. User interface to control all connected channels. PMLA-S Slave device with PMLA system bus for operating with a master device and output for another slave device. Cooling unit Empty cooler module (without load modules) with 4 assembly...

Open the catalog to page 4
Brochure PMLA - 5

1) Maximum DC input voltage 2) Minimum adjustable resistance 3) Maximum adjustable resistance 4) Rise and fall times are specified at 10 ... 90 % of maximum current Model Types (order number) PMLA-M PMLA Master device with RS-232 + USB + LAN + PMLA system bus 5) Required assembly positions at cooling unit. A load module cannot be spread over several coolers. Subject to modification without notice, errors and omissions expected Power Distribution Source-Sink AC & DC Multi-Channel Mulit-Channel, GUI Energy Recycling Multi-Range High Power Low Power H&H

Open the catalog to page 5
Brochure PMLA - 6

Power Distribution Source-Sink AC & DC Multi-Channel Mulit-Channel, GUI Energy Recycling Multi-Range High Power Low Power H&H Software Tools PMLA Series Setting Menu The PMLA Tool is a graphical software tool to control up to 72 load channels of the PMLA series Electronic Loads. The user can choose different functions with the aid of the navigation bar. The most important load settings are done in the Main Menu ("Settings"). Several graphical widgets inform the user about the measurements and the current device status. Further on, a data logging function can be...

Open the catalog to page 6
Brochure PMLA - 7

Operation, Contact, Mechanics PMLA Series All dimensions in mm Subject to modification without notice, errors and omissions expected Power Distribution Source-Sink AC & DC Multi-Channel Mulit-Channel, GUI Energy Recycling Multi-Range High Power Low Power H&H

Open the catalog to page 7
Brochure PMLA - 8

GTC SE Accessories NL ZSAC PMLI PMLA ERI ZS PLI PLA This is Power Distribution Source-Sink AC & DC Multi-Channel Mulit-Channel, GUI Energy Recycling Multi-Range High Power Low Power H&H Technical Data PMLA Series Accuracy of setting of the setting value of the corresponding range Input resistance >10 kft GND max. ±2 V with respect to negative load input Accuracy of analog measurement outputs 0 ... 10 V for current, voltage of analog signal real value Offset voltage GND max. ±2 V with respect to negative load input Minimum load capacity 2...

Open the catalog to page 8
Brochure PMLA - 9

Subject to modification without notice, errors and omissions expected

Open the catalog to page 9
Brochure PMLA - 10

General Standard Terms and Conditions of Business (GTC) of Höcherl & Hackl GmbH (H&H) Version 05.03.2015 § 1 General Information - Scope of Application (1) Our General Standard Terms and Conditions of Business shall apply exclusively; we shall not recognize any terms or conditions on the part of the customer that oppose or deviate from our General Standard Terms and Conditions of Business unless we have expressly agreed to their applicability in writing. Our General Standard Terms and Conditions of Business shall apply even if we carry out delivery to the customer without reservation in the...

Open the catalog to page 10
Brochure PMLA - 11

(10) The period of limitation in the case of a delivery claim to damages in accordance with Sections 478, 479 of the German Civil Code [BGB] shall remain unaffected; it shall amount to five years as of delivery of the defective item. (11) Required material and working hours shall be calculated following elapse of the warranty period. The purchaser of the service (customer) shall be responsible for both the forwarding expenses to us and return shipment. In the case of on site repairs the costs of travel and the return journey, mileage and, if necessary, overnight accommodations shall be...

Open the catalog to page 11
Brochure PMLA - 13

'ocher/ A Hackl GmbH DC & AC . 100V' lOOkW Sing Multichannel I^iSiSiSiSiSi! Johann Hackl Helmut Hocherl 30 Years H&H The Electronic Load

Open the catalog to page 13
Brochure PMLA - 14

Höcherl & Hackl GmbH Industriestraße 13 94357 Konzell GERMANY Phone.: +49 9963/94301- 0 Fax.: +49 9963/94301-84 E-Mail: office@hoecherl-hackl.com PLMA excerpt from Catalog_E_03

Open the catalog to page 14

All Höcherl & Hackl catalogs and technical brochures

  1. PMLA Series

    10 Pages

  2. ZS Series

    12 Pages

  3. NL Series

    11 Pages

  4. PMLI Series

    6 Pages

  5. PL Series

    5 Pages

  6. Main catalogue

    76 Pages

  7. NL Source-Sink

    12 Pages

Archived catalogs

  1. NL SERIES

    11 Pages