Brochure ERI Series
12Pages

{{requestButtons}}

Catalog excerpts

Brochure ERI Series - 1

Energy Recycling Load

Open the catalog to page 1
Brochure ERI Series - 2

Energy Recycling Load ERI Series Energy recycling excels waste heat Environmental protection Lower electricity costs High Power Power Distribution Energy Recycling Silent fans Less air-condition Pleasant laboratory conditions Subject to modification without notice, errors and omissions expected

Open the catalog to page 2
Brochure ERI Series - 3

Interface Overview Energy Recycling Load ERI Series • Energy recycling to the local power grid • Low heat waste - silent - lab operation • CC - CV - CR - CP - CCV - CVC mode • Ethernet + USB + RS-232 + CAN as standard • GPIB optional • SCPI Programming with measurement function • Dynamic loads with synchronized DAQ • Data storage directly to USB mass storage device • Adjustable protections for voltage and current • Electronic protection • Digital input and programmable output • Galvanically isolated fast I/O Port optional SCPI Description ERI Series Electronic Loads feed the consumed energy...

Open the catalog to page 3
Brochure ERI Series - 4

Mechanics / Terminals Energy Recycling The consumed energy is fed back to the mains supply. The operation in the sense of a power generation into the public electricity grid is not provided with these energy recycling loads. The load must be connected to a low-voltage mains supply with a fixed High Power installed and separately fused supply line. The ERI load has a simple and non-redundant monitoring of the power supply. If limit values are exceeded, it switches off the power stage unit. This monitoring does not replace any grid or system protection which must be installed if necessary for...

Open the catalog to page 4
Brochure ERI Series - 5

Data Acquisition / Dynamic Functions / Tools ERI Series Data Acquisition The standard Data Acquisition function expands the possibilities of the device by the following items: • Storing measurement data to external USB flash drive (timestamp, voltage and current) • Fast synchronized data logging with internal data memory for waveform generation (timestamp, voltage and current) Example: Data logging with constant sampling rate Dynamic Function In CC, CV, CR and CP mode, complex load profiles can be realized by List function. 300 load levels with a corresponding ramp and dwell time can be...

Open the catalog to page 5
Brochure ERI Series - 6

Power Distribution Source-Sink AC & DC Multi-Channel Mulit-Channel, GUI Energy Recycling Multi-Range High Power Low Power H&H 1) Rise and fall times are defined of 10 ... 90 % and 90 ... 10 % of the maximum current at 10 % of the maximum input voltage (current mode, tolerance ±20 %). Times will vary at different settings. 2) Minimum input voltage for maximum load current 3) 230 / 400 VAC +10 % -15 %, 50 Hz, 1-phase at 3.6 kW, 2-phase at 7.2 kW, 3-phase at 10.8 kW 4) Power consumption in idle operation (without load current) 5) Maximum achievable efficiency 6) Measured...

Open the catalog to page 6
Brochure ERI Series - 7

Technical Data ERI Series Accuracy of setting Accuracy of analog control 0 ... 10 V (with option ERI06) Subject to modification without notice, errors and omissions expected GTC SE Accessories NL ZSAC PMLI PMLA ERI ZS PLI PLA This is Power Distribution Source-Sink AC & DC Multi-Channel Mulit-Channel, GUI Energy Recycling Multi-Range High Power Low Power H&H

Open the catalog to page 7
Brochure ERI Series - 8

General Standard Terms and Conditions of Business (GTC) of Höcherl & Hackl GmbH (H&H) Version 05.03.2015 § 1 General Information - Scope of Application (1) Our General Standard Terms and Conditions of Business shall apply exclusively; we shall not recognize any terms or conditions on the part of the customer that oppose or deviate from our General Standard Terms and Conditions of Business unless we have expressly agreed to their applicability in writing. Our General Standard Terms and Conditions of Business shall apply even if we carry out delivery to the customer without reservation in the...

Open the catalog to page 8
Brochure ERI Series - 9

(10) The period of limitation in the case of a delivery claim to damages in accordance with Sections 478, 479 of the German Civil Code [BGB] shall remain unaffected; it shall amount to five years as of delivery of the defective item. (11) Required material and working hours shall be calculated following elapse of the warranty period. The purchaser of the service (customer) shall be responsible for both the forwarding expenses to us and return shipment. In the case of on site repairs the costs of travel and the return journey, mileage and, if necessary, overnight accommodations shall be...

Open the catalog to page 9
Brochure ERI Series - 11

'ocher/ A Hackl GmbH DC & AC . 100V' lOOkW Sing Multichannel I^iSiSiSiSiSi! Johann Hackl Helmut Hocherl 30 Years H&H The Electronic Load

Open the catalog to page 11
Brochure ERI Series - 12

Hocherl & Hackl GmbH Industriestr. 13 94357 Konzell GERMANY Phone: +49 9963/94301-0 Fax: +49 9963/94301-84 E-Mail: office@hoecherl-hackl.com Excerpt from Catalog_E_03

Open the catalog to page 12

All Höcherl & Hackl catalogs and technical brochures

  1. PMLA Series

    10 Pages

  2. ZS Series

    12 Pages

  3. NL Series

    11 Pages

  4. Brochure PMLA

    14 Pages

  5. PMLI Series

    6 Pages

  6. PL Series

    5 Pages

  7. Main catalogue

    76 Pages

  8. NL Source-Sink

    12 Pages

Archived catalogs

  1. NL SERIES

    11 Pages