XEROSORP+ - 1

XEROSORP+ Flue gas cleaning

Open the catalog to page 1
XEROSORP+ - 2

XEROSORP+ Flue gas cleaning XEROSORP+: Competitive, complete, compact The Xerosorp+ process combines the advantages of the dry scrubbing process and low temperature SCR-DeNOx system. Removal of acidic gaseous and organic contaminants together with heavy metal compounds is ensured by a dry scrubbing step in the first part of the unit. The multi chamber catalyst in the second part insures that NOx contaminants are removed effectively through the injection of ammonia between the fabric filter and the catalyst. || Dry scrubbing for efficiency and low residue levels The dry scrubbing flue gas...

Open the catalog to page 2
XEROSORP+ - 3

| SCR DeNOx at low temperature with periodical catalyst regeneration Downstream the Fabric filter ammonia is injected into the flue gas in the short connecting duct. The SCR DeNOx system operates at temperatures below 200°C and consists of several chambers. Periodically the SCR catalyst is reactivated chamber by chamber in an offline mode while the whole FGC remains on full operation at nominal load. | Improved energy efficiency with tail end heat recovery The flue gas temperature downstream the SCR DeNOx is lowered just above due point, thus recovering maximum energy in the flue gas...

Open the catalog to page 3
XEROSORP+ - 4

XEROSORP+ Flue gas cleaning Hitachi Zosen Hitachi Zosen Inova AG | Hardturmstr. 127 | P.O. Box 680 | 8037 Zurich | Switzerland