Scroll Compressors for Commercial Air Conditioning - 1

HEAD QUARTER New Pier Takeshiba South Tower 1-16-1, Kaigan Minato-ku, Tokyo 105-0022, JAPAN www.jci-hitachi.com Johnson Controls Hitachi Air Conditioning Europe SAS ITALY Via A. Manzoni 44,20095 Cusano Milanino (MI) www.hitachiaircon.it UK Whitebrook Park Lower Cookham Road, Maidenhead, SL6 8YA www.hitachi-hvac.com The specifications of this catalog may change without prior notice to allow Hitachi Cooling & Heating to incorporate the latest innovations for its customers. The information contained in this catalog is merely informative. Hitachi Cooling & Heating declines any responsibility in the broadest sense, for damage, direct or indirect, arising from the use and / or interpretation of the recommendations in this catalog. CERTIFICATION GB/T28001-2011 / OHSAS18001:2007 Johnson Controls-Hitachi Wanbao Compressor (Guangzhou) Co., Ltd. Initial Issue Date: April 30, 2006 [Certificate No. 15918S20003R4M] GB/T19001-2016 / ISO9001:2015 Johnson Controls-Hitachi Wanbao Compressor (Guangzhou) Co., Ltd. Initial Issue Date: July 8, 2004 [Certificate No. 15918Q20011R6M] GB/T24001-2016 / ISO14001:2015 Johnson Controls-Hitachi Wanbao Compressor (Guangzhou) Co., Ltd. Initial Issue Date: April 30, 2006 [Certificate No. 15918E20005R4M] Scroll Compressors for Commerical Air Conditioning R410A I DC INVERTER HITACHI

Open the catalog to page 1
Scroll Compressors for Commercial Air Conditioning - 2

PRODUCT FEATURES CAPACITY RANGE Hitachi High Efficiency Gas Injection DC Inverter Scroll Compressor 1. Direct Suction Reduces superheat, improved volumetric efficiency. 2. Improved Asymmetric Wrap Additional displacement and superheat reduction for greater compressor efficiency. 3. High Efficiency Motor Maintains high efficiency levels across wide speed range of 10-140 rps. 4. Internal Oil Circulation Structure Low oil circulation rates (<2%) keeping oil in the compressor for superior reliability. 5. Gas Injection Technology Lower discharge temperatures, increasing capacity and...

Open the catalog to page 2
Scroll Compressors for Commercial Air Conditioning - 3

SPECIFICATION – & DIMENSION PRODUCT SPECIFICATION Rated Performance Displacement Power Input Weight (include oil) Oil balance piping kg Model Name Cooling Capacity Power Input Weight (include oil) Oil balance piping Power supply 3 phase Rated Performance Gas Injection Power supply 3 phase PRODUCT SPECIFICATION Model Name *Cooling capacity is based on AHRI Standard 540 condition (Dew point) and rotation speed at 60Hz. *Cooling capacity is based on AHRI Standard 540 condition (Dew point) and rotation speed at 60Hz. Side View Oil balance piping (Y, J Type) Injection Connection (K, Y) (ID Φ9.7...

Open the catalog to page 3
Scroll Compressors for Commercial Air Conditioning - 4

PRODUCT SPECIFICATION Series *Cooling capacity is based on AHRI Standard 540 condition (Dew point) and rotation speed at 60Hz. PRODUCT DIMENSION (DC80) Suction Pressure (MPa G) Suction Pressure (MPa G) Side View Gas Injection (Y Type) Unit: (mm) Suction Pressure (MPa G) Suction Pressure (MPa G) *Pressure is relative (gauge) pressure. *Pressure Ratio e (The absolute Pressure basis) c=(Discharge Port Pressure) / (Suction Port Pressure) R410AI DC INVERTER 06

Open the catalog to page 4

All Hitachi-Johnson Controls Air Conditioning Inc. catalogs and technical brochures

  1. dehumidifiers

    24 Pages

  2. RCME-AH

    2 Pages

  3. FSXNH

    2 Pages

  4. FSXN

    2 Pages

  5. FSNM

    2 Pages

  6. Cooling Only

    2 Pages

  7. KPI-Energy

    2 Pages

  8. KPI Active

    2 Pages

  9. Yutaki

    2 Pages

  10. KPI series

    2 Pages

  11. FS(V)N(Y)2E

    2 Pages

  12. Utopia ES

    2 Pages

Archived catalogs

  1. Heat pumps

    7 Pages