RCUE-WG2 Water Cooled

RCUE-WG2 Water Cooled

RCUE-WG2 Water Cooled

Product catalog summary
Overview
The Hitachi Samurai RCUE-WG2 series offers water-cooled chillers designed for cooling only or heat pump applications. These chillers are renowned for their reliability, utilizing advanced twin screw compressors for superior partial load performance and high seasonal efficiencies. They are suitable for industrial and process applications such as data centers, shopping centers, airports, hotels, hospitals, and offices.
Features and Benefits
  • Capacities range from 40HP to 240HP (134kW to 696kW).
  • Precise control of outlet water temperature to +/- 0.5°C, independent of cooling load.
  • Continuous capacity control offers 15% to 20% energy savings compared to step control.
  • Energy efficiency with an ESEER of up to 4.83.
  • STAR DELTA starting system minimizes maximum starting current.
  • Low noise and vibration levels.
  • Compact design allows for high cooling capacity per square meter.
Technical Specifications
  • Cooling capacities range from 134 kW to 696 kW.
  • Heating capacities (for heat pump option) range from 161.1 kW to 824.2 kW.
  • Power input for cooling ranges from 33.5 kW to 163.5 kW.
  • Power input for heating ranges from 39.8 kW to 194.2 kW.
  • Energy Efficiency Ratio (EER) and Coefficient of Performance (COP) are around 4.0 to 4.3.
  • Sound power levels range from 83 dB(A) to 93 dB(A).
  • Sound pressure levels range from 68 dB(A) to 77 dB(A).
  • Dimensions vary with height from 1520 mm to 1700 mm, width at 1105 mm, and depth from 850 mm to 2350 mm.
  • Net weight ranges from 750 kg to 2670 kg.
Control Systems
  • BMS Interfaces available with Modbus CHL-MBS-01, capable of controlling up to 8 chillers.
  • Optional control systems include CSC 5S central controller, Lonworks® HARC-70CE1, and CS Net Web for web-based control.
Installation and Operation
  • Continuous capacity control ranges from 15% to 100%.
  • Water pipe connections use 3" or 5" Victaulic fittings.
  • Leaving water outlet temperature for cooling is 5°C to 15°C (with a -10°C option).
  • Leaving water outlet temperature for heating is 25°C to 55°C.
  • Condenser water outlet temperature ranges from 22°C to 45°C (with a 55°C option).
Notes
  • Cooling capacities are based on the European Standard EN12055.
  • Sound pressure levels are measured at 1m from the control panel surface and 1.5m from the floor level.
See more

Catalog excerpts

RCUE-WG2 Water Cooled-1

Hitachi Air Conditioning Engineered for tomorrow. Samurai RCUE-WG2 Water Cooled Cooling Only or Heat Pump The Samurai range of chillers offer worldrenowned reliability – thanks to our own twin screw compressors – and incorporate the latest developments in screw compressor technology for excellent partial load performance and high seasonal efficiencies. Our Chillers are ideally suited for Industrial and process applications: data centres, shopping centres, airports, hotels, hospitals and offices. Optional Control Systems Features and Benefits Capacities from 40HP to 240HP (134kW to 696kW) CSC 5S Central controller (up to 8 Samurai Chillers) Control outlet water temperature to +/- 0.5°C independent of cooling load Continuous capacity control provides 15% to 20% energy saving compared to step control ESEER of up to 4.83 STAR DELTA starting system reduces the maximum starting current Excellent partial load performance Low noise and vibration Very small installation space Thanks to meticulous design of each component, it is possible to achieve exceptionally high cooling capacity values per square metre. World Renowned Reliability with Hitachi’s Twin Screw Compressor With few moving parts, it is highly reliable with very low noise level and low vibration Modbus CHL-MBS-01 Can control up to 8 RCUE-WG2 chillers (Chiller modules >3 cycles are counted as 2 Chillers) Lonworks® HARC-70CE1 (OP) Control and monitor up to 4 Samurai chillers

 Open the catalog to page 1
RCUE-WG2 Water Cooled-2

Water Cooled RCUE 40WG2 Cooling Capacity1 Heating Capacity2 Power Input (Cooling)1 Power Input (Heating)2 EER COP ESEER Sound Power Level Sound Pressure Level Height Width Depth Net Weight Capacity Control Number of Circuits Water Pipe Connection (Evaporator) Water Pipe Connection (Condenser) Leaving Water Outlet Temperature (Cool) Leaving Water Outlet Temperature (Heat) Condenser Water Outlet Temperature7 NOTES: 1. The nominal cooling capacities are based on the European Standard EN12055. Chilled Water Inlet / Outlet Temperature: 12 / 7°C Cooling Water Inlet / Outlet Temperature: 30 / 35°C 2....

 Open the catalog to page 2

All Hitachi-Johnson Controls Air Conditioning Inc. catalogs and technical brochures

  1. dehumidifiers

    24  Pages

  2. RCME-AH

    2  Pages

  3. FSXNH

    2  Pages

  4. FSXN

    2  Pages

  5. FSNM

    2  Pages

  6. Cooling Only

    2  Pages

  7. KPI-Energy

    2  Pages

  8. KPI Active

    2  Pages

  9. Yutaki

    2  Pages

  10. KPI series

    2  Pages

  11. FS(V)N(Y)2E

    2  Pages

  12. Utopia ES

    2  Pages

*Prices are pre-tax. They exclude delivery charges and customs duties and do not include additional charges for installation or activation options. Prices are indicative only and may vary by country, with changes to the cost of raw materials and exchange rates.