Product catalog summary
Overview: The Hitachi FSXNH modular system offers a versatile air conditioning solution with options for 2-pipe heat pump or 3-pipe heat recovery, adaptable to customer needs. The system is lightweight, modular, and supports long piping runs, making it suitable for various design requirements.
Specifications:
  • Cooling capacities range from 14kW to 100kW.
  • Heating capacities range from 16kW to 112kW.
  • Energy efficiency is market-leading, with low noise options available.
  • Supports up to 59 indoor units depending on the model.
  • Total maximum pipe run is 1000 meters.
Features and Benefits:
  • Winner of the Japanese Energy Efficiency and Conservation Award 2013.
  • Enhanced Capital Allowance (ECA) scheme status, offering tax relief for energy-efficient investments.
  • Flexibility with System Free indoor units that can be combined with Utopia splits or Set Free VRF ranges.
Changeover Boxes: Hitachi Changeover Boxes facilitate easy switching between 2-pipe and 3-pipe systems, with simplified installation and servicing due to reduced piping connections and flexible electrical box positioning.
Outdoor Units:
  • Various models (e.g., RAS 5FSXNH to RAS 36FSXNH) with different cooling and heating capacities.
  • Power supply: 400V / 3Ph / 50Hz.
  • Nominal Load Efficiency (EER/COP) varies by model, maintaining high energy class ratings (A/A).
  • Dimensions and weight vary by model, with specific piping diameter requirements.
  • Working range for cooling is -5°C to 43°C and for heating is -20°C to 15°C.
Technical Considerations:
  • Maximum indoor units and piping lengths have specific restrictions; consult the Technical Catalogue for details.
  • Sound power levels are measured according to EN12102 standards.
See more

Catalog excerpts

FSXNH-1

Hitachi Air Conditioning Engineered for tomorrow. FSXNH modular 2-pipe or 3-pipe Set Free VRF 2-pipe heat pump or 3-pipe heat recovery available from a single unit to adapt to customer requirements. Each outdoor unit is lightweight and modular which – combined with long piping runs and improved height difference – means Set Free VRF can meet any design brief. Awarded Enhanced Capital Allowance (ECA) scheme status Cooling capacities from 14kW to 100kW Heating capacities from 16kW to 112kW The ECA Scheme is part of the Government’s programme of measures to manage climate change which gives businesses tax relief for investing in energy-efficient, accredited products - making it possible to claim a 100% first year capital allowance against the taxable profits in the period of investment (rather than claiming on a reducing balance). Market-leading energy efficiency Low noise – select from 3 settings with up to 8dB noise reduction 2-pipe heat pump or 3-pipe heat recovery (requires CH Box) Connectable to up to 59 system free indoor units (dependant on model) Total maximum pipe run of 1000 metres Hitachi’s System Free indoor units can be combined with outdoor units from either our Utopia splits or Set Free VRF ranges for ultimate flexibility. Japanese Energy Efficiency and Conservation Award 2013 winner. Changeover Boxes Hitachi Changeover (CH) Boxes are compatible with the Set Free heat recovery systems and enable a change from 2-pipe heat pump and 3-pipe heat recovery on our FSXN and FSXNH products as customer requirements change. Installations are quick and simple as the strainer is installed at the manufacturing stage and piping connections are reduced from 5 down to 3. The electrical box can be positioned at either side of the CH Box for easier servicing. Power supply Nominal capacity Maximum number of indoor units Electricity demand Weight Piping diameter Outdoor Unit to CH Box (High/Low Pressure) Piping diameter - From Indoor Unit Recommended fuse size

 Open the catalog to page 1
FSXNH-2

Hi Efficiency Modular 2 or 3-Pipe Outdoor Unit Outdoor Combination Power supply Nominal Cooling Capacity Nominal Heating Capacity UK Cooling Capacity Maximum Indoor Units(1) Minimum - Maximum connected capacity Nominal Load Efficiency EER / COP(2) Energy Class (Cool/Heat) Dimensions (H / W / D) Weight Piping diameter (Liquid / Gas x 2) Total Piping Length / Height Difference Max Piping Length (outdoor to indoor) Working Range (cooling / heating) Outdoor Unit Outdoor Combination Power supply Nominal Cooling Capacity Nominal Heating Capacity UK Cooling Capacity Maximum Indoor Units(1) Minimum -...

 Open the catalog to page 2

All Hitachi-Johnson Controls Air Conditioning Inc. catalogs and technical brochures

  1. dehumidifiers

    24  Pages

  2. RCME-AH

    2  Pages

  3. FSXN

    2  Pages

  4. FSNM

    2  Pages

  5. Cooling Only

    2  Pages

  6. KPI-Energy

    2  Pages

  7. KPI Active

    2  Pages

  8. Yutaki

    2  Pages

  9. KPI series

    2  Pages

  10. FS(V)N(Y)2E

    2  Pages

  11. Utopia ES

    2  Pages

*Prices are pre-tax. They exclude delivery charges and customs duties and do not include additional charges for installation or activation options. Prices are indicative only and may vary by country, with changes to the cost of raw materials and exchange rates.