Overview
Hitachi's industrial dehumidifiers are engineered for diverse applications such as food drying, precision machinery room dehumidification, and concrete drying. They employ a refrigeration cycle to cool and condense humid air, effectively removing moisture. Models are available in reheating and cooling types to maintain stable room temperatures.
Product Line-Up
The product range includes compact floor models with advanced control features via an optional multi-function wired controller, enabling multiple unit control, remote operation, and easy timer settings.
Main Features
Models like RK-NP08PVX and RK-NP2LVX boast high dehumidification capacity and energy efficiency through inverter control, allowing optimal performance under varying load conditions. A powerful mode is available for rapid response to increased dehumidification demands.
Specifications & Dimensions
Specifications include dehumidification capacity, compressor output, and energy consumption. Inverter models offer up to 20% annual power consumption savings compared to constant speed types.
Optional Parts and Modifications
A variety of optional parts such as filter boxes, duct sets, and high-efficiency filters are available. Installation is streamlined with pre-assembled components like the plenum chamber.
Common Features
Inverter-equipped models feature easier installation and improved serviceability, with direct blower-motor connections eliminating V belt adjustments. The design supports easy cleaning and maintenance, minimizing performance deterioration risks.
Demand Control and Power Management
The demand control feature manages compressor operating current to limit maximum power consumption, with settings from 100% to 40% of rated power. A wave mode alternates demand control to reduce humidity fluctuations and power use. Setup requires distributor assistance.
Operating Temperature Range
The dehumidifiers function across a wide temperature range, adaptable to various humidity and temperature conditions.
Control Panel Features
The control panel includes a multi-function wired controller, powerful dehumidification mode, full-dot LCD, and easy timer function. It displays power consumption for effective power-saving management.
Power Saving Modes
Peak Save and Restrict Mode adjust dehumidification capacity and compressor speed to manage power consumption within desired limits.
Intermittent Operation Control
This feature cycles between dehumidification and thermo-off modes to conserve power, with specific settings for reheat mode.
Multiple Unit Control
Up to 10 dehumidifiers can be controlled from a single panel, with specific wiring guidelines. Different types or series cannot be combined for control.
Anticorrosive Coating
Standard anticorrosive coating is applied to indoor units, particularly on evaporator hairpin tubes, to prevent corrosion.
Antibacterial and Deodorant Air Filters
Antibacterial filters have activity values of 5.3 to 5.4, tested per JIS standards. Deodorant filters are effective against certain odors but not toxic substances like carbon monoxide.
Installation and Usage Notes
Remote control operations require a twisted-pair cable of 0.75mm2 or greater. The duct chamber includes a flexible duct but is not self-supporting.
Optional Parts and Models
Models like RK-NP2LVX, RK-NP4LVX, and RK-NP8LVX have specific parts like plenum chambers and filter boxes. Detailed specifications for filters include dimensions and maintenance periods.
Filter Specifications
Long life filters have a 50% dust collection efficiency, while high efficiency filters achieve 65% using the colorimetric method. Deodorant filters absorb general odors and are available for rear suction configurations.
Maintenance and Cleaning
Filters can be reused by drying in sunlight or washing with water, but detergents should be avoided. Maintenance periods depend on usage conditions, and filter installation affects air volume and dehumidification capacity.
See more

Catalog excerpts

dehumidifiers-1

Johnson Controls - Hitachi Air Conditioning ADDRESS HITACHI. CERTIFIED QUALITY New Pier Takeshiba South Tower 1-16-1, Kaigan Minato-ku, Tokyo 105-0022, JAPAN Tel: +81-3-6721-5567 www.jci-hitachi.com The specifications of this catalog may change without prior notice to allow Hitachi Cooling & Heating to incorporate the latest innovations for its customers. The information contained in this catalog is merely informative. Hitachi Cooling & Heating declines any responsibility in the broadest sense, for damage, direct or indirect, arising from the use and / or interpretation of the recommendations in this catalog. Find the products Hitachi Cooling & Heating with the best service and conditions at your Hitachi Distributor. Johnson '))$ Controls HITACHI Air conditioning solutions INDUSTRIAL DEHUMIDIFICATION REHEATING ONLY TYPE REHEATING AND COOLING TYPE HITACHI Protect your environment, - where value is born.

 Open the catalog to page 1
dehumidifiers-2

38 Optional parts and modifications

 Open the catalog to page 2
dehumidifiers-3

OVERVIEW Hitachi's commercial/industrial dehumidifiers are valuable in various fields for the purpose of dehumidification and drying. Places where humidity tends to be high due to the presence of water and steam - Indoor pools and fitness clubs - Dehumidification and drying of bathing areas in public bathrooms and inns Dehumidification, drying, and storing : 04 At food processing plants, manufacturing facilities and logistics businesses - Drying and storing of fresh and processed food - Drying of food processing plants after cleaning with water At workshops and work facilities - Dehumidification...

 Open the catalog to page 3
dehumidifiers-4

Reheating only type HITACHI Small floor type (inverter-equipped) Floor type (inverter-equipped) Small floor type (inverter-equipped) Model Floor type (inverter-equipped) RK-NP2LVX (with plenum chamber*) RK-NP4LVX (with plenum chamber*) RK-NP8LVX (with plenum chamber*) RK-NP2LTVX RK-NP4LTVX RK-NP8LTVX Reheating and cooling type Floor type (inverter-equipped) Note * Plenum chamber for direct air blow into the room is optional. 1. Dehumidification Capacity shows the value when Dehumidifier runs at rating and maximum frequency. 2. This is the capacity in reheat mode.The capacity in cooling mode is...

 Open the catalog to page 4
dehumidifiers-5

MAIN - EATURES Small floor type (inverter-equipped) < Reheating only type > ENHANCED CONTROL FEATURES Small floor type with small footprint. Enhanced control features by optional multi-function wired controller. Extensive product line-up The optional multi-function wired controller supports various functions. * For the following functions, an optional multi-function wired controller is required. * If the optional caster wagon is used, mount the controller on the side of the wagon. Multiple unit control function Up to 10 dehumidifiers (small floor type) can be controlled at the same time. SMALL...

 Open the catalog to page 5
dehumidifiers-6

MAIN - EATURES Floor type (inverter-equipped) < Reheating only type > REDUCED ENERGY CONSUMPTION HITACHI Inverter control allows the unit to be used under a wide range of dehumidification load conditions as well as reducing energy consumption. It also makes it possible to reach the set humidity level within a shorter time and to respond to a greater fluctuation of dehumidification load. Depending on the fluctuation of the dehumidification load, the compressor speed is controlled by the inverter to adjust the dehumidification capacity. Compared to the constant speed type, power consumption is...

 Open the catalog to page 6
dehumidifiers-7

MAIN - EATURES Floor type (inverter-equipped) < Reheating and cooling type > Cooling Operation RK-NP2LTVX RK-NP8LTVX HITACHI Inverter control allows the unit to be used under a wide range of dehumidification load conditions as well as reducing energy consumption. As it is a reheating and cooling type, it can prevent temperature increases in the room. Note: *5. Cooling Capacity indiates the values for the operation under the conditions: Air inlet temperature 25°C and Air inlet humidity 80%(Outside Air inlet temperature 30°C) *1. Plenum chamber is optional. Extensive product line-up REDUCTION ENERGY...

 Open the catalog to page 7
dehumidifiers-8

COMMON - EATURES Floor type (inverter-equipped) Floor type (inverter-equipped) & Small floor type (inverter-equipped) HITACHI WIDE SELECTION OF OPTIONAL PARTS A wide selection of optional parts is supported, such as a filter box for the front suction, duct set for the rear suction, and high efficiency filter. (For details, refer to P38~P45.) The system performs demand control by detecting the operating current of the compressor. This feature helps suppress the maximum power by cutting the power consumption which exceeds the set power range. * Small floor type require the optional multi-function...

 Open the catalog to page 8
dehumidifiers-9

COMMON - EATURES Floor type (inverter-equipped) & Small floor type (inverter-equipped) Useful power saving features * The following three control functions cannot be enabled simultaneously. It takes a long time to reach the set humidity/temperature (reheating andcooling type). HITACHI MULTI-FUNCTION OF CONTROL PANEL The control panel supports the wired controller (PC-RKF). You can configure various features by simple operation. * The small floor type requires the optional multi-function wired controller. Powerful dehumidification (quick dehumidification) Pressing the Powerful dehumidification...

 Open the catalog to page 9
dehumidifiers-10

COMMON – FEATURES STANDARD ANTICORROSIVE COATING (INDOOR UNIT) Floor type (inverter-equipped) & Small floor type (inverter-equipped) MULTIPLE UNIT CONTROL Up to 10 dehumidifiers can be controlled at the same time from a single control panel. Following the wiring guideline below, wire the units correctly. Wiring guideӏine Remove the wiring connecting the control panels of units #1 through #9 and the terminal block (TB2). (Example for floor type) Heat exchanger (anticorrosive coating) (Example for small floor type) *Clear acrylic resin coating Generally, the hairpin tubes on the ends of the evaporator...

 Open the catalog to page 10
dehumidifiers-11

SPECIFICATIONS -< DIMENSIONS Small floor type (inverter-equipped) < Reheating only type > Dimensional drawing of dehumidifier with Caster wagon (optional) (mm) Dimensional drawing of handle for Movement (optional) Caster Wagon Model: CW08-1 RK-NP08PVX 0.6kW 0.8Equivalent horsepower Specifications (50Hz) Dimensional drawing (mm) Model Fixing Plate for Floor (Both Side) Control Panel Details Options Dimensional drawing of medium efficiency Filter (optional) Model: F08-1 Dimensional drawing of caster (optional) Model: C08-1 [Caster(with Stopper)] Dimensional drawing of round duct (optional) (mm)...

 Open the catalog to page 11

Archived catalogs

  1. Utopia ES

    2  Pages

  2. FS(V)N(Y)2E

    2  Pages

  3. KPI series

    2  Pages

  4. Yutaki

    2  Pages

  5. KPI Active

    2  Pages

  6. KPI-Energy

    2  Pages

  7. Cooling Only

    2  Pages

  8. FSNM

    2  Pages

  9. FSXN

    2  Pages

  10. FSXNH

    2  Pages

  11. RCME-AH

    2  Pages

  12. Heat pumps

    7  Pages

*Prices are pre-tax. They exclude delivery charges and customs duties and do not include additional charges for installation or activation options. Prices are indicative only and may vary by country, with changes to the cost of raw materials and exchange rates.