Centrifugal Chiller

Centrifugal Chiller
1 / 12 PagesView full catalog

Centrifugal Chiller

Product catalog summary
Overview: The document provides comprehensive details on Hitachi's high-efficiency centrifugal chillers, specifically the GFG-S/SIT, GXG-S/SIT, and GSG-S/SIT series. These chillers are engineered for energy efficiency, compactness, and reliability, addressing global warming by reducing CO2 emissions.
Key Features:
  • High-Efficiency Compressor: Features a 3-dimensional blade impeller and optimally designed diffuser with vane, operating at low speeds to minimize energy loss.
  • Semi-Hermetic Design: Ensures long-term stable operation and high efficiency.
  • Energy-Saving: Achieves a maximum COP of 7.0, contributing significantly to energy savings.
  • Compact Design: Lightweight and compact, facilitating easy installation and space-saving.
  • Global Warming Prevention: Reduces energy consumption and CO2 emissions, addressing climate change concerns.
Technical Specifications:
  • Refrigerant Cycle: Utilizes a 2-stage compression cycle with an economizer to enhance efficiency.
  • Heat Exchanger: Employs high-performance heat exchange tubes and an optimal structural design.
  • Refrigerant: Uses ozone-safe HFC134a.
  • Capacity Range: 1,055~7,032kW (300~2,000USRT) for standard models and 1,055~4,922kW (300~1,400USRT) for inverter-controlled models.
Operational Features:
  • Lubrication System: Direct refrigerant cooling of lubrication oil increases reliability.
  • Surge Protection: Operates stably under high cooling water temperatures, preventing surges.
  • Control Panel: Features a 10.4-inch color touch panel for easy operation, monitoring, and data storage.
  • Compatibility: Equipped with RS485 communication port for integration with Building Management Systems via MODBUS RTU protocol.
Additional Features:
  • Automatic restart after power failure.
  • Variable flow control for chilled and cooling water.
  • Ball type automatic tube cleaning system.
  • Delivery in knockdown form for easy transport and installation.
Specifications and Features: The document outlines the specifications of Hitachi High Efficiency Inverter-Controlled Centrifugal Chillers, designed for stable operation under high cooling water temperatures. They utilize a 3D 2-stage impeller to prevent surge occurrences and offer a wide operating range, maintaining stability even with rising condenser pressure due to high ambient temperatures or tube fouling.
Key Features:
  • Key-free impeller coupling system.
  • Accurate chilled water temperature control within ±0.2˚C.
  • Low noise and longer bearing life due to lower rotation speed of the 2-stage compression cycle.
  • Continuous oil recovery with an automatic refrigerant cleaner.
  • Prevention of oil degradation by removing residual water with a filter dryer.
Operational Functions: The chillers are equipped with various operational functions to enhance efficiency and reliability, including variable speed control of the compressor, improved COP during winter, energy-saving modes, and cooling water variable flow operation.
Efficiency and Performance: The chillers demonstrate excellent efficiency throughout the year, with a maximum partial load COP of 22.4 and an IPLV of 11.5. Efficiency is enhanced by minimizing the use of vane control and extending the motor speed control range.
Technical Specifications: Detailed technical specifications include model dimensions, COP ranges, and power requirements. Specifications are subject to change for technical improvements, and consultation with sales staff is advised for specific operating parameters.
Conclusion: Hitachi's centrifugal chillers are designed for high efficiency and energy-saving operations, suitable for year-round cooling needs. They incorporate advanced technologies to improve performance under varying conditions, making them a reliable choice for efficient cooling solutions.
See more

Catalog excerpts

Centrifugal Chiller-1

Centrifugal Chiller High Efficiency GFG-S/SIT Series GXG-S/SIT Series GSG-S/SIT Series

 Open the catalog to page 1
Centrifugal Chiller-2

Centrifugal Chiller High Efficiency Centrifugal Chiller ■ HC-F-GFG-SSC Series HC-F-GXG-S Series (High Efficiency Type) HC-F-GSG-S Series (Compact Type) (Super High Efficiency Type) 1,055~7,032kW (300~2,000USRT) *Capacity can be extended up to max. 2,500USRT with single compressor. High Efficiency Inverter Controlled Centrifugal Chiller ■ HC-F-GFG-SITSC Series HC-F-GXG-SIT Series (High Efficiency Type) HC-F-GSG-SIT Series (Compact Type) (Super High Efficiency Type) Hitachi High Efficiency Centrifugal Chillers realize world top-level high efficiency and downsizing thanks to the advanced technologies...

 Open the catalog to page 2
Centrifugal Chiller-3

Global Warming Prevention Energy saving by high-efficiency centrifugal chillers Global warming refers to the phenomenon of global rising in average atmospheric temperatures due to increased volume of CO2 and methane as a result of burning fossil fuels such as petroleum and coal. The 1995 IPCC* Report predicted that if the emission of CO2, etc. continued as it was, the atmospheric temperature would rise by as much as 2˚C by the end of the 21st century and, as a result, the sea level would rise by approximately 50 cm from the present level. In such circumstances, it is even more important to save...

 Open the catalog to page 3
Centrifugal Chiller-4

Advantages Easy Operation with Touch Panel Type Control Panel Top-class Compact Design and Light Weight Design The compact design greatly improves flexibility in installation. Realizing space saving of machine room. Easy carry-in to machine room. Suitable for replacement of long-operating chillers. Significant reduction of refrigerant volume. 10.4 inch color touch panel screen Monitor various operating data Indicate trend graph during operation Trend data for max. 40 hours. (Updated every 1 hour) Indicate and store operation history for the past 12 hours (Updated every hour) Indicate and store...

 Open the catalog to page 4
Centrifugal Chiller-5

Low press. low temp. suction gas 2-stage Compression Cycle To improve compressor efficiency, refrigerant economizer is added with 2-stage compressor equipped with 2 impellers, as shown in the drawing below. In this case, the refrigerant goes through two expansion devices. When the refrigerant goes through the first device, some of the refrigerant flashes, or become a gas. The flashed refrigerant is introduced to the compressor between the two stages. In the one-stage compressor cycle without the economizer, all refrigerant flows in the cycle. Comparatively, in the 2-stage compressor cycle the...

 Open the catalog to page 5
Centrifugal Chiller-6

Advantages Hitachi High Efficiency Inverter Controlled Centrifugal Chiller Hitachi High Efficiency Inverter-controlled Centrifugal Chillers realize energy-saving operation through out the year utilizing variable motor speed control with inverter unit, drastically improving partial load efficiency under low cooling water temperature condition in off-peak seasons. In addition, the chillers have many unique energy saving functions which satisfy the demand to minimize the energy consumption. High Efficiency 2-stage Compressor Excellent Efficiency throughout the Year Max. Partial Load COP IPLV High...

 Open the catalog to page 6
Centrifugal Chiller-7

Excellent COP at Partial Load Energy & Power Saving Operation Functions Various technologies such as newly developed high efficiency economizer (cyclonic system), etc. enabled drastic improvement of the efficiency at partial load with low cooling water temperature. Improvement of the oil supply temperature control and the automatic oil recovery enables extension of the motor speed control range at low cooling water inlet temperature. Max. Partial Load The chiller is usually controlled so the chilled water outlet temperature to be constant. This "Eco Mode" operation introduces the inlet temperature...

 Open the catalog to page 7
Centrifugal Chiller-8

■ HC-F GFG-SSC | Constant Speed

 Open the catalog to page 8
Centrifugal Chiller-9

■ HC-F GXG-S | Constant Speed REMARKS 1. Please consult with our sales staff or distributor for actual specifications for cooling capacity, expected kW input and COP, depending on selected operating parameters. 2. The above specifications are subject to change without notice for technical improvements. * This table is applicable to chillers to be manufactured for normal water. 3. Capacity control range is 100% to approx. 20%. (Minimum cooling capacity can be reduced to 10% as option.) 4. Fouling factor is assumed to be 0.018m2K/kW for chilled water and 0.044m2K/kW for cooling water. 5. Standard...

 Open the catalog to page 9
Centrifugal Chiller-10

■ HC-F_GSG-S | Constant Speed

 Open the catalog to page 10
Centrifugal Chiller-11

Standard Scope of Supply The following table shows the standard scope of supply, but the actual scope depends on the contract. Please consult with our sales staff or distributor. Item Standard Scope Main Equipment Compressor, Main motor, Lubrication system, Heat exchanger Aux'l'ar E u ment Safety device, Control panel, Standard accessories (Corrugated rubber vibration insulator plates, Oil strainer elements, Gasket for oil strainer elements, Dryer), Starter (optional) Chiller main unit: Anti-corrosive prime coating Coating Control panel: Finish coat (color: Munsell 5Y8/1 gloss) Starter (optional):...

 Open the catalog to page 11

Archived catalogs

  1. Utopia ES

    2  Pages

  2. FS(V)N(Y)2E

    2  Pages

  3. KPI series

    2  Pages

  4. Yutaki

    2  Pages

  5. KPI Active

    2  Pages

  6. KPI-Energy

    2  Pages

  7. Cooling Only

    2  Pages

  8. FSNM

    2  Pages

  9. FSXN

    2  Pages

  10. FSXNH

    2  Pages

  11. RCME-AH

    2  Pages

  12. dehumidifiers

    24  Pages

  13. Heat pumps

    7  Pages

*Prices are pre-tax. They exclude delivery charges and customs duties and do not include additional charges for installation or activation options. Prices are indicative only and may vary by country, with changes to the cost of raw materials and exchange rates.