Air Cooled Heat Pump
2Pages

{{requestButtons}}

Catalog excerpts

Air Cooled Heat Pump - 1

Hitachi Air Conditioning Engineered for tomorrow. Samurai RCU2E-AG2 Air Cooled Cooling Only, Samurai RHU2E-AG2 Air Cooled Heat Pump The Samurai range of chillers offer world-renowned reliability – thanks to our own twin screw compressors – and incorporate the latest developments in screw compressor technology for excellent partial load performance and high seasonal efficiencies. Our Chillers are ideally suited for Industrial and process applications: data centres, shopping centres, airports, hotels, hospitals and offices. Optional Control Systems RCU2E-AG2 Air Cooled Cooling only - capacities from 40HP to 400HP (112kW to 1030kW) CSC 5S Central controller (up to 8 Samurai Chillers) RHU2E-AG2 Air Cooled Heat Pump - capacities from 40HP to 240HP (106kW to 585kW) ESEER of up to 3.52 Control outlet water temperature to +/- 0.5°C independent of cooling load Continuous capacity control provides 15% to 20% energy saving compared to step control STAR DELTA starting system reduces the maximum starting current Excellent partial load performance Low noise and vibration Very small installation space Thanks to meticulous design of each component, it is possible to achieve exceptionally high cooling capacity values per square metre Optional recovery system Recover 30% of the output power in cooling mode by heating the water in a dedicated circuit with outlet temperatures up to 70ºC at maximum working conditions. BMS Interfaces Hydraulic Module Option Single and Dual Pump Models Hitachi Hydraulic modules are a compact design integrated inside the Chiller unit. They are assembled with all interconnecting piping and wiring during manufacture ready for installation. Available with or without buffer tank. World Renowned Reliability with Hitachi’s Twin Screw Compressor With few moving parts, it is highly reliable with very low noise level and low vibration Modbus CHL-MBS-01 Can control up to 8 RCU2E-AG2 chillers (Chiller modules >3 cycles are counted as 2 Chillers) Lonworks® HARC-70CE1 (OP) Control and monitor up to 4 Samurai chillers

Open the catalog to page 1
Air Cooled Heat Pump - 2

Air Cooled Cooling Only RCU2E 40AG2 Cooling Capacity1 Power Input EER ESEER Sound Power Level (Std/LN/SLN) Sound Pressure Level (Std/LN/SLN)3 Height Width Depth Net Weight Capacity Control Number of Circuits Water Pipe Connection Leaving Water Outlet Temperature Ambient Temperature Air Cooled Heat Pump RHU2E 40AG2 Cooling Capacity1 Heating Capacity2 Power Input (Cooling) Power Input (Heating) EER COP ESEER Sound Power Level Sound Pressure Level (Std/LN/SLN)3 Height Width Depth Net Weight Capacity Control Number of Circuits Water Pipe Connection Leaving Water Outlet Temperature (Cool)...

Open the catalog to page 2

All Hitachi-Johnson Controls Air Conditioning Inc. catalogs and technical brochures

  1. dehumidifiers

    24 Pages

  2. RCME-AH

    2 Pages

  3. FSXNH

    2 Pages

  4. FSXN

    2 Pages

  5. FSNM

    2 Pages

  6. Cooling Only

    2 Pages

  7. KPI-Energy

    2 Pages

  8. KPI Active

    2 Pages

  9. Yutaki

    2 Pages

  10. KPI series

    2 Pages

  11. FS(V)N(Y)2E

    2 Pages

  12. Utopia ES

    2 Pages

Archived catalogs

  1. Heat pumps

    7 Pages