Catalog excerpts
Hitachi Air Conditioning Engineered for tomorrow. Samurai RCME-AH Hi Efficiency, Air Cooled Cooling only The Samurai range of chillers offer world-renowned reliability – thanks to our own twin screw compressors – and incorporate the latest developments in screw compressor technology for excellent partial load performance. Equipped with inverter-driven fans and intelligent control system for optimum seasonal efficiency – Samurai RCME-AH is highly effective even at partial load. Our Chillers are ideally suited for Industrial and process, data centres, shopping centres, airports, hotels, hospitals and offices. Features and Benefits Flexible modular concept allows project customisation on efficiency, price or installation space Capacities from 106kW to 1280kW ESEER of 4.32 to 5.01 Intelligent control system for optimum SEER even at partial load Control outlet water temperature to +/- 0.5°C independent of cooling load All Inverter-driven fan motors for optimised efficiency LCD touch screen panel New U-shape heat exchanger with enhanced aluminium fins for 20% more exchange surface 2 plate heat exchangers delivers improved refrigerant distribution and greater efficiency Electronic expansion valve with PID control New twin screw compressor optimised for R134a with continuous capacity control Awarded Enhanced Capital Allowance (ECA). Modbus CHL-MBS_01 Can control up to 8 RCME-AH chillers (8 chillers x 8 modules = 64 modules) Awarded Enhanced Capital Allowance (ECA) scheme status RCME 40AH Module Cooling Capacity1 Power Input EER (inc. pump) ESEER (inc. pump) Sound Power Level (Std/LN/SLN) Sound Pressure Level (Std/LN/SLN)2 Height / Width / Depth Net Weight Capacity Control Number of Circuits Water Pipe Connection Leaving Water Outlet Temperature Ambient Temperature 2 ½” Victaulic (1 x Inlet / 1 x Outlet) 80 / tbc / tbc 81 / tbc / tbc 81 / tbc / tbc 82 / tbc / tbc 82 / tbc / tbc 2450 / 2250 / 4000 2910 2945 2980 3035 Continuous Capacity Control 12.5 ~ 100 2 2 2 2 2 ½” Victaulic (2 x Inlet / 2 x Outlet) Common Water Pipe Connection Option available The ECA Scheme is part of the Government’s programme of measures to manage climate change which gives businesses tax relief for investing in energyefficient, accredited products - making it possible to claim a 100% first year capital allowance against the taxable profits in the period of investment (rather than claiming on a reducing balance). The nominal cooling capacities are based on the European Standard EN14511. Chilled Water Inlet / Outlet Temperature : 12 / 7°C. Condenser Inlet Air Temperature : 35°C Sound Pressure level measured at 1.5m height and 1m from control panel NOTES: 3 Basic Modules (40, 50 and 60HP) Customise selection for either Energy Efficiency, Price or Installation space Combine up to 8 Modules to match higher capacities (40 & 60HP modules cannot be combined) Two Operating Modes as standard; selected at Commissioning • Steady water outlet temperature (+/- 0.5°C). All compressors running at the same load • Hi Efficiency Mode, Smart control of compressors start/stop operation Option for up to 4 modules to be factory connected on a single base frame (RCME 080/2AH ~ RCME 240/4AH)
Open the catalog to page 1Hi Efficiency Air Cooled Cooling Only RCME 120/3AH Power Input Sound Power Level (Std/LN/SLN) Sound Pressure Level (Std/LN/SLN)2 Height / Width / Depth Capacity Control 4500 Continuous Capacity Control Number of Circuits Water Pipe Connection 2 ½” Victaulic (3 x Inlet / 3 x Outlet) Common Water Pipe Connection Option available Leaving Water Outlet Temperature Ambient Temperature RCME 160/4AH Module Cooling Capacity Power Input Sound Power Level (Std/LN/SLN) Sound Pressure Level (Std/LN/SLN)2 Height / Width / Depth Capacity Control Number of Circuits Water Pipe Connection Leaving Water...
Open the catalog to page 2All Hitachi-Johnson Controls Air Conditioning Inc. catalogs and technical brochures
-
For Data Center Application
2 Pages
-
For Refrigeration Application
28 Pages
-
INDUSTRIAL DEHUMIDIFICATION
24 Pages
-
For Heat Pump Application
12 Pages
-
Centrifugal Chiller
12 Pages
-
dehumidifiers
24 Pages
-
HITACHI SCREW COMPRESSORS
3 Pages
-
Hermetic compressors
5 Pages
-
RCME-AH
2 Pages
-
FSXNH
2 Pages
-
FSXN
2 Pages
-
FSNM
2 Pages
-
Room Air Conditioners
17 Pages
-
Air Cooled Heat Pump
2 Pages
-
Cooling Only
2 Pages
-
KPI-Energy
2 Pages
-
RCUE-WG2 Water Cooled
2 Pages
-
KPI Active
2 Pages
-
ES Outdoor Units
2 Pages
-
IVX Premium Outdoor Units
2 Pages
-
IVX Comfort Outdoor Units
2 Pages
-
Yutaki
2 Pages
-
Shirokuma Wall Mounted Units
2 Pages
-
S-Series Wall Mounted
2 Pages
-
Ducted In the Ceiling
2 Pages
-
Monozone 600 x 600 Cassette
2 Pages
-
KPI series
2 Pages
-
FS(V)N(Y)2E
2 Pages
-
Utopia ES
2 Pages
-
Summit Wall Mounted RAK-PEB
2 Pages
Archived catalogs
-
Yutaki Heat Pumps
2 Pages
-
Heat pumps
7 Pages
-
Utopia Split Systems
24 Pages
-
Room Air Conditioners
29 Pages
-
AquaFREE System
2 Pages