Solutions provided by Hitachi High-Tech Science to analyze 10 substances restricted under the RoHS directive Cadmium, Lead, Mercury Hexavalent chromium Phthalates (DEHP, BBP, DBP, DIBP) Thermal Desorption MS (Screening Device for Phthalates) Atomic Absorption Analyzer High-Performance Liquid Chromatograph Quantitative precision analysis Chromaster series SCION SQ series - From screening tests to quantitative precision analysis Hitachi High-Tech Science serves every analytical needs of customers with an abundant line-up of products. *This logo is the trademark of Hitachi High-Technologies Corporation throughout the world. http://www.hitachi-hightech.com/hhs/ Head Office Sales Division 24-14,Nishi-shinbashi,1-chome,Minato-ku Tokyo 105-0003,Japan Hitachi Instruments (Shanghai)Co.,Ltd. Hitachi high-Technologies America, Inc. Hitachi High-Technologies Europe GmbH(Mannheim office)

Open the catalog to page 1
HM1000 - 2

Quick and Simple Testing for Phthalates! For testing substances restricted under the amended RoHS Directive, a quicker and simpler on-site screening for Phthalates is required. Phthalates are widely used as plasticizers for softening plastic and rubber in wire sheaths, electrical insulation tape, and packing films, etc. The amendment to the RoHS Directive to restrict the use of the four Phthalates (DEHP, BBP, DBP, DIBP) from July 2019 has created an urgent compliance issue. A variety of plastic and rubber are used in electrical and electronic equipment. It is expected that a large number of...

Open the catalog to page 2
HM1000 - 3

High-speed measurement Measurement at a rate of less than 10 minutes! Easy operation from sample preparation to analysis! Vaporized compounds are ionized and directly analyzed by a mass spectrometer enabling high-speed measurement. (Separation column is not required) Place the sample in the sample pan and position it on the sample tray. Next, by following simple software steps, measurements will be started by the autosampler. The autosampler diagram is displayed on the software and the progress of measurements and the results (PASS/FAIL judgment) can be verified easily. Heating to...

Open the catalog to page 3
HM1000 - 4

Measurement examples In order to separate the isomers (DEHP and DOTP) DOTP can be fragmented, enabling the conclusive identification of DEHP. A peak will appear at molecular weight +1 for each phthalate after protonation. *Measurement of total Phthalates is required for DBP and DIBP (both are at m/z=279) The measuring sample : Certified Reference Material NMIJ CRM 8152-a APCI (Atomospheric Pressure Cheimcal Ionization) Mass spectrometer Quadruple mass filter Measurement mode Mass detection Solid, Powder ⋅ Scan mode ⋅ SIM (Selected Ion Monitoring) mode (Max. 20channels) *Each...

Open the catalog to page 4

All Hitachi High-Tech Analytical Science catalogs and technical brochures

  1. OE Series

    8 Pages

  2. FT200 Series

    7 Pages

  3. NEXTA DMA200

    8 Pages

  4. EA8000A

    5 Pages

  5. OE SERIES

    2 Pages

  6. FM EXPERT

    4 Pages

  7. FT110A

    6 Pages

  8. FT160

    6 Pages

  9. CMI165

    2 Pages

  10. Lab-X5000

    3 Pages