PASS – Plug And Switch System
12Pages

{{requestButtons}}

Catalog excerpts

PASS – Plug And Switch System - 1

High-voltage hybrid switchgear

Open the catalog to page 1
PASS – Plug And Switch System - 2

Pioneer and technology leader Hitachi Energy is a pioneering technology leader that works closely with utility, industry and infrastructure customers to improve their performances while lowering environmental impact. Hitachi Energy operates in more than 90 countries. Hitachi Energy is a global technology leader with a combined heritage of almost 250 years, employing around 38,000 people in over 90 countries. Headquartered in Switzerland, the business serves utility, industry and infrastructure customers across the value chain and emerging areas like sustainable mobility, smart cities,...

Open the catalog to page 2
PASS – Plug And Switch System - 3

2008 Release issue of the 62271-205 standards for hybrid modules – International Electrotechnical Commission (IEC) 2010 Launch of the PASS for H-configured substations 2015 Launch of the PASS for digital substations 2020 Launch of the PASS M00 – Wind for offshore wind turbine applications More than 10,000 installed PASS bays worldwid

Open the catalog to page 3
PASS – Plug And Switch System - 4

High-voltage hybrid switchgear Compact switchgear is fully assembled and high-voltage tested in the factory for rapid installation and energization. Bushings Composite bushings are used exclusively, as they are explosion-proof and resistant to pollution. Cable termination PASS can make use of cables instead of bushings. Combined disconnector/ earthing switch The gas-insulated combined DS/ES makes interlocking simple and intrinsically safe. Circuit-breaker The circuit-breaker is a single-break interrupter that operates by means of the self-blast principle. Circuit-breaker drive PASS is...

Open the catalog to page 4
PASS – Plug And Switch System - 6

PASS M00 – 72.5 to 100 kV Up to 2500 A, 31.5 kA PASS M00 is perfectly suited for distribution grids, renewable integration and consumer applications such as data centers, mining and rail. PASS M0 – 145 to 170 kV Up to 3150 A, 63 kA The PASS M0 is designed to reduce substation footprints and life cycle costs. Its design has been validated in 100 countries, covering all climate regions and numerous applications. PASS M0S 245 kV Up to 4000 A, 50 kA The PASS M0S provides outstanding compactness for transmission-level substations. It is based on components commonly used across our switchgear...

Open the catalog to page 6
PASS – Plug And Switch System - 7

Customer benefits and technical ratings Space-saving design: Each PASS module is equivalent to a complete switchgear bay, with function integration that leads to a footprint reduction of up to 60 percent compared to traditional solutions and minimizes costs for civil works. High level of flexibility: Numerous configurations, like single busbar, double busbar, double-circuit breaker and H-configured switchgear, are available together with other customized configurations, allowing the best solution for each specific customer’s needs. Customer benefits Fast erection and commissioning: Fully...

Open the catalog to page 7
PASS – Plug And Switch System - 8

Digital solutions Digital transformation is the key to meeting the energy industry’s most urgent challenges, such as aging infrastructure and increasing energy demand. In addition, the rise in renewable power generation has also impacted grid reliability and stability. With these challenges in consideration, digitalization helps the industry modernize its assets. Hitachi Energy is continuously developing its digital switching and components portfoli, which brings significant value to high-voltage switchgear applications. Digitally-enabled switchgear provides higher safety and reliability...

Open the catalog to page 8
PASS – Plug And Switch System - 9

PASS - PLUG AND SWITCH SYSTEM HIGH-VOLTAGE HYBRID SWITCHGEAR | 9 Modular Switchgear Monitoring (MSM): The MSM is an add-on system to supervise the module status. PASS module main parameters, such as gas and switching element conditions, are continuously measured and displayed in a consolidated view, facilitating instant detection of critical situations and improving station condition awareness. MSM operates independently from existing control and protection devices and provides the base layer for a condition-based and predictive maintenance strategy. Protection, control and merging unit:...

Open the catalog to page 9
PASS – Plug And Switch System - 10

ENERGY INTENSIVE INDUSTRIES PASS hybrid switchgear is the perfect solution for different types of applications as it provides reliable performance by combining GIS and AIS technology advantages. RENEWABLE ENERGY SEGMENT Moreover, it has a flexible and compact design with simple installation and commissioning and virtually no maintenance for its entire life in service. DATA CENTERS PASS hybrid switchgear is the product of choice for modern customers looking for high reliability within a modular and compact design. RAILWAY APPLICAT

Open the catalog to page 10
PASS – Plug And Switch System - 11

Commitment We are advancing the world’s energy system to be more sustainable, flexible and secure. As the pioneering technology leader, we collaborate with customers and partners to enable a sustainable energy future. Quality assurance Hitachi Energy is committed to providing the best products and services. Our products comply with or exceed the latest international standards. In addition to type tests in independent laboratories, our certified design and manufacturing quality assurance processes guarantee the highest quality. Sustainability We are advancing the world’s energy system to be...

Open the catalog to page 11
PASS – Plug And Switch System - 12

Hitachi Energy Ltd High Volta; g ■ I’t' - IN' cts Hybrid switch; r ar contact-us@hitachienergy.com www.hitachienergy.com ©Hitachi Energy 2023. All rights reserved. Specifications subject to change without notice.

Open the catalog to page 12

All Hitachi Energy catalogs and technical brochures

  1. PQactiF

    12 Pages

  2. Cooling System

    12 Pages

  3. ETL600 R4