POWER QUALITY ANALYZER PQ3198
24Pages

{{requestButtons}}

Catalog excerpts

POWER QUALITY ANALYZER PQ3198 - 1

POWER QUALITY ANALYZER PQ3198, PQ3100 [new] Investigate power characteristics and analyze the causes of problems Exceptional ease of use and international standard-compliant reliability Analytical Software

Open the catalog to page 1
POWER QUALITY ANALYZER PQ3198 - 2

Maintain and manage power supplies and analyze problems more easily and reliably than ever before POWER QUALITY ANALYZER PQ3198 and PQ3100 The critical importance of electrical power in today's society necessitates daily maintenance and management to ensure that problems don’t occur. When they do, for example due to an equipment failure or abrupt surge in demand, engineers face the need to analyze the cause quickly. The POWER QUALITY ANALYZER PQ3198 and PQ3100 provide robust support for field personnel who need to analyze power characteristics in the form of measurement capabilities that...

Open the catalog to page 2
POWER QUALITY ANALYZER PQ3198 - 3

Analyze equipment power problems Capture the full range of power supply anomalies, including momentary interruptions, voltage drops, and frequency fluctuations, while recording trends to help investigate the causes of unexpected equipment malfunctions and sudden stoppages. Record quality data for power systems Record fluctuations in voltage, current, power, harmonics, and flicker when connecting a highly variable system such as a renewable energy source or EV charging station to the grid. Easily analyze the data with the included PQ ONE software. Measure AC/DC power Use AC/DC auto-zero...

Open the catalog to page 3
POWER QUALITY ANALYZER PQ3198 - 4

High-end model Troubleshoot power supplies and verify power quality Class A compliance under international standards Basic voltage measurement accuracy of ±0.1% High-voltage, wideband performance Two-circuit measurement Simple inverter measurement 400 Hz line measurement GPS time synchronization Extensive array of event measurement parameters Investigate power supply anomalies Verify the quality of power from a solar power system Verify the quality of power supplied by an EV rapid charger Investigate the causes of equipment failures and malfunctions, including issues that are difficult to...

Open the catalog to page 4
POWER QUALITY ANALYZER PQ3198 - 5

High-precision, wideband, broad-dynamic-range measurement The PQ3198 delivers the high-end specifications and high reliability needed to capture the full range of power anomalies and analyze the underlying data with a high degree of precision. The PQ3198 complies with the IEC 61000-4-30 Ed. 2 Class A standard. As a result, it can perform standard-mandated measurement tasks such as gapless, continuous calculation; detection of events such as swells, dips, and interruptions; and time synchronization using GPS (optional). Basic measurement accuracy (50/60 Hz) Thanks to basic measurement...

Open the catalog to page 5
POWER QUALITY ANALYZER PQ3198 - 6

Mid-range model Investigate power supply conditions and prevent problems Features Simple setup with QUICK SET Record event waveforms of up to 11 sec. in duration 8 hours of battery operation 200 ms and 600 ms data save capability CAT III (1000 V)/CAT IV (600 V) Display event statistics Demand recording Investigate power supply conditions Measure voltage fluctuations, equipment capacity, and harmonics before installing new electrical equipment. You can also check whether newly installed equipment is affecting other equipment by repeating those measurements after installation and comparing...

Open the catalog to page 6
POWER QUALITY ANALYZER PQ3198 - 7

Launch QUICK SET to navigate the connection and setup processes so you can get started recording quickly. (example: 2-meter power measurement of a 3-phase/3-wire circuit) Connect the voltage cables and current sensors to the circuit to be measured. Current sensor Current range The instrument will perform an automatic wiring check and display the results. 1 i || Voltage phase 1 Current input II XJ/Turrent phase 1 Phase difference Bilx jPr tDPF) You need only set the recording parameters and interval in order to start measurement. Recording parameters can be set simply by choosing a simple...

Open the catalog to page 7
POWER QUALITY ANALYZER PQ3198 - 8

Features shared by both the PQ3198 and the PQ3100 Measurement functionality and data recording capabilities that ensure you’ll capture the full picture with a single measurement Capture power anomalies reliably with simple settings The PQ3198 and PQ3100 can measure all parameters at once, including power, harmonics, and anomaly waveforms. The instruments also provide simple setup functionality for automatically configuring recording parameters for popular applications. Capture power supply anomalies reliably | Transient voltages Capture phenomena characterized by precipitous voltage changes...

Open the catalog to page 8
POWER QUALITY ANALYZER PQ3198 - 9

Extensive range of recording pa, rameters Simultaneously record event waveforms and trend graphs Each time it makes a measurement, the PQ3198/PQ3100 records trend data for all parameters. When a power anomaly is detected, an event is recorded. Since the instrument records the maximum, minimum, and average values during the interval, you can rest assured that you won’t miss peak values. Simultaneous recording of waveforms and trend data | Event waveform When an event occurs, the instrument records the instantaneous waveform for 0.2 seconds. Triggers can be set for all event parameters in...

Open the catalog to page 9
POWER QUALITY ANALYZER PQ3198 - 10

I Flexible sensors: Easy installation in confined locations Flexible current sensors provide a convenient way to measure double- and triple-wired power supplies and in confined locations, with capacities of up to 6000 A. I Auto-zero sensors: Stable measurement of DC power over extended periods of time Auto-zero current sensors allow measurement of DC power over extended periods of time, eliminating the need to concern yourself with zero-point drift. | No need for an external power supply Since sensor power is supplied by the instrument, there’s no need for an AC adapter when using AC/DC...

Open the catalog to page 10
POWER QUALITY ANALYZER PQ3198 - 11

| When it's hard to clip leads to terminals In locations where it’s hard to attach alligator clip-style leads to metal terminals, you can replace the tips of the voltage cords with magnetic adapters so that you can more easily detect the voltage. | Secure the PQA to the side of a distribution panel Use two heavy-duty magnetic straps to attach the instrument to the side or door of a distribution panel. Magnetic adapters are easy to affix to terminals in confined locations. Magnetic straps can also be used to help keep voltage cords from coming loose. Extensive range of interfaces | Remote...

Open the catalog to page 11