LCR METER IM3523, IM3523A, IM3533
16Pages

{{requestButtons}}

Catalog excerpts

LCR METER IM3523, IM3523A, IM3533 - 1

From Production Lines to Research and Development A New Series of LCR Meters to Meet Your Applications LCR METER Models IM3523, IM3523A, IM3533, and IM3533 - 01 are highly cost-effective testers that provide greater perfor mance and better f unctionality than previous HIOK I models, such as a high basic accuracy of ±0.05%, a wide measurement frequency from 1 mHz (40 Hz for the IM3523, IM3523A) to 200 kHz, high-speed measurement of up to 2 ms, highly reliable measurement using the contactcheck function, and measurement of turn ratio and mutual inductance. Select the best model according to your application, from production lines to research and development.

Open the catalog to page 1
LCR METER IM3523, IM3523A, IM3533 - 2

The Perfect Impedance Analyzer Product Lineup IM3523 *1 *1 The check and double-check marks in the “Usage” rows indicate the recommendation level. Usage” The double-check mark represents a highly recommended application. Research and development Transformer and Usage Usag e *1 coil production Z (impedance [Ω]) Y (admittance [S]) θ (phase angle [°]) Rs (equivalent series resistance = ESR [Ω]) Rp (parallel resistance [Ω]) X (reluctance [Ω]) G (conductance [S]) B (susceptance [S]) Ls (series inductance [H]) Lp (parallel inductance [H]) Cs (series capacitance [F]) Cp (parallel capacitance [F])...

Open the catalog to page 2
LCR METER IM3523, IM3523A, IM3533 - 3

For Lead Components and Surface Mounted Devices (SMDs) Probes & Test Fixtures Please use the probes specified below. All probes are constructed with a 1.5D-2 V coaxial cable. Probes and Test Fixtures for Lead Components Cable length 1 m (3.28 ft), DC to 8 MHz, impedance characteristics of 50 Ω, 4-terminal pair configuration, measurable conductor diameter: ø0.3 mm (0.01 in) to ø5 mm (0.20 in) max. Direct connection type, DC to 8 MHz, measurable conductor diameter: ø0.3 mm (0.01 in) to ø2 mm (0.08 in) max. Cable length 1 m (3.28 ft), DC to 200 kHz, impedance characteristics of 50 Ω,...

Open the catalog to page 3
LCR METER IM3523, IM3523A, IM3533 - 4

High-Speed, High-Accuracy, and Easy-to-Use Basic Performance ● Wide measurement frequency range The measurement frequency can be freely set to DC or any value in the 1 mHz (40 Hz for the IM3523, IM3523A) to 200 kHz range at high resolution (five-digit resolution [1 mHz resolution for less than 100 Hz]). This makes it possible to measure the resonant frequency and perform measurement and evaluation under conditions close to actual conditions. Measurement frequency[Hz] In addition to normal open-loop signal generation, these models enable voltage/current dependent measurement in constant...

Open the catalog to page 4
LCR METER IM3523, IM3523A, IM3533 - 5

Features of LCR Meter Model IM3523, IM3523A Integration into Production Lines and Automated Machinery ● General specifications of the IM3523, IM3523A ● Easy setup using a numeric keypad on a simple, easyto-read monochrome LCD A simple user interface is provided with a high-contrast graphic LCD display, function keys, and numeric keypad. For numeric value settings such as the comparator setting, the numeric keypad can be used to enter numbers easily and quickly. Basic meaZ,Y,θ,Rs,Rp,X,G,B,Ls,Lp,Cs,Cp,Q,D surement items Rdc 3 Measurement items Transformer − measurement Temperature T − Basic...

Open the catalog to page 5
LCR METER IM3523, IM3523A, IM3533 - 6

Features of LCR Meter Model IM3533 Winding, Coil and Transformer Production ● General specifications of the IM3533 Turn ratio N, mutual inductance M, and inductance difference ΔL can be measured on the transformer measurement screen. ● Rdc measurement with temperature compensation*2 For Rdc measurement of inductor and transformer windings, measurement can be performed while compensating for temperature. *2 Temperature Probe 9478 (option) is required for Rdc measurement with temperature compensation. ● Simultaneously display 4 parameters (for normal measurement) For normal measurement, four...

Open the catalog to page 6
LCR METER IM3523, IM3523A, IM3533 - 7

Features of LCR Meter Model IM3533-01 Research and Development and Electrochemistry ● General specifications of the IM3533 -01 Measurements can be performed automatically at up to 801 frequency points by specifying the frequency range or in the frequency list mode. The measurement results can be saved to a USB flash drive or to a computer via an interface, which then can be used to perform frequency analysis of samples. Basic measureZ,Y,θ,Rs,Rp,X,G,B,Ls,Lp,Cs,Cp,Q,D ment items Rdc 3 (with temperature compensation function) Measurement items Transformer N,M,Δ L measurement Temperature T 3...

Open the catalog to page 7
LCR METER IM3523, IM3523A, IM3533 - 8

Capacitors and Inductors C-D + ESR Measurement of Capacitors Continuous measurement can be performed with high speed under multiple conditions! LCR mode [IM3523(A)] [IM3523(A)] Cs and D display screen (120 Hz measurement) Continuous measurement screen [IM3523(A)] [IM3523(A)] LCR mode [IM3523(A)] [IM3523(A)] Rs display screen (100 kHz measurement) C-D (120 Hz) and low ESR (100 kHz) measurement can be performed for functional polymer capacitors. Different measurement items can be measured continuously under different measurement conditions (frequency, level, and mode). C Measurement of Polar...

Open the catalog to page 8
LCR METER IM3523, IM3523A, IM3533 - 9

Transformer Winding and Sweep Measurements Variety of Transformer Winding Measurement Functions In addition to the L-Q and Rdc measurements, the IM3533 and IM3533-01 enable you to measure the turn ratio N, mutual inductance M, and inductance difference ΔL that are required for the measurement of transformers.* Connections must be switched manually or a selector such as a scanner unit is required separately. Turn ratio N measurement (1) Measure L (L1) on the primary side (2) Measure L (L2) on the secondary side (3) Calculate turn ratio N from L1 and L2 Transformer measurement mode Turn ratio...

Open the catalog to page 9
LCR METER IM3523, IM3523A, IM3533 - 10

Capturing Measurement Data ● Saving and loading data via front USB port Measurement results and settings can be saved to a commercially available USB flash drive connected to the front USB port. (The USB port on the front panel is specifically for a USB flash drive. Batch save all the measurement results to a USB flash drive after saving them to the internal memory of the IM3533(-01). Some USB flash drives may not be supported due to incompatibility issues.) Measurement results and settings Temperature sensor connection connector IM3523 rear panel ● Connecting to a PC via USB Save to USB...

Open the catalog to page 10