Overview: The LCR Meter series, including models IM3523, IM3523A, IM3533, and IM3533-01, is designed for advanced testing in production lines and research and development. These meters offer high accuracy, a broad frequency range, and rapid measurement speeds, making them suitable for diverse testing environments.
Specifications: The meters feature a basic accuracy of ±0.05% and a frequency range from 1 mHz to 200 kHz. They support measurement voltages from 5 mV to 5 V and can perform measurements in as little as 2 ms. The IM3533 models include additional features like internal DC bias measurement and a color TFT LCD touch panel.
Measurement Capabilities: These meters can measure parameters such as impedance (Z), admittance (Y), phase angle (θ), and equivalent series resistance (Rs). The IM3533 models also support transformer measurements, including turn ratio (N) and mutual inductance (M).
Features for Production Lines: Designed for integration into automated systems, the meters offer compact size, comparator functions, and BIN measurement capabilities, along with a contact check function for reliable measurements.
Probes and Test Fixtures: A variety of probes and test fixtures are available, including four-terminal probes and SMD test fixtures, supporting different conductor diameters and measurement frequencies.
Advanced Functions: The IM3533 models provide easy touch screen operation, power indicators, and instrument mode indicators for enhanced usability. They support continuous measurement under various conditions and offer protection against charged capacitors.
Conclusion: The LCR Meter series offers versatile and high-performance testing solutions for both production and research environments, with models tailored to specific needs and advanced features to enhance measurement accuracy and efficiency.
Low Impedance High Accuracy Mode: This mode improves repeat accuracy in low-impedance measurements, useful for low-inductance inductors and ESR of aluminum electrolytic capacitors, operating at 100 mΩ and 1 Ω ranges with an output resistance of 25 Ω.
Frequency Sweep: The IM3533-01 can perform automatic measurements at up to 801 frequency points, allowing comprehensive frequency analysis, with results saved to USB or computer.
Data Connectivity: The IM3533-01 connects to PCs or PLCs via RS-232C, LAN, or GP-IB, allowing remote control and data download, with data saving/loading via a front USB port.
EXT I/O Interface: The handler interface outputs measurement signals and inputs control signals, with photocoupler isolation to protect against noise, supporting various signal outputs and inputs for comprehensive control and data management.
Measurement Accuracy: Detailed accuracy tables for various impedance and resistance ranges are provided, highlighting coefficients and conditions affecting measurement precision.
Standards and Conditions: Devices comply with EMC standard EN61326-1 and safety standard EN61010, with operating conditions of 0°C to 40°C and humidity of 80% RH or less. Storage conditions are -10°C to 50°C with similar humidity constraints.
Recommendations: For optimal performance, use a coaxial cable with 50 Ω impedance and a 4-terminal pair configuration. Perform open and short compensation after powering on the device for at least 60 minutes.
Accessories and Options: Various accessories are available, including power cords, instruction manuals, and test fixtures. Optional interfaces include RS-232C, GP-IB, and LAN connections. Probes and test fixtures suitable for different measurement applications are listed.
SMD Test Fixture IM9110: Designed for SMDs with side electrodes, covering a frequency range from DC to 120 MHz, suitable for SMD sizes of 3.5 ±0.5 mm. For SMDs with bottom electrodes, the range is DC to 8 MHz, accommodating sample sizes from 01005 to 0402 (EIA) and 0402 to 1005 (JIS).
See more

Catalog excerpts

LCR METER IM3523, IM3523A, IM3533-1

From Production Lines to Research and Development A New Series of LCR Meters to Meet Your Applications LCR METER Models IM3523, IM3523A, IM3533, and IM3533 - 01 are highly cost-effective testers that provide greater perfor mance and better f unctionality than previous HIOK I models, such as a high basic accuracy of ±0.05%, a wide measurement frequency from 1 mHz (40 Hz for the IM3523, IM3523A) to 200 kHz, high-speed measurement of up to 2 ms, highly reliable measurement using the contactcheck function, and measurement of turn ratio and mutual inductance. Select the best model according to your application, from production lines to research and development.

 Open the catalog to page 1
LCR METER IM3523, IM3523A, IM3533-2

The Perfect Impedance Analyzer Product Lineup IM3523 *1 *1 The check and double-check marks in the “Usage” rows indicate the recommendation level. Usage” The double-check mark represents a highly recommended application. Research and development Transformer and Usage Usag e *1 coil production Z (impedance [Ω]) Y (admittance [S]) θ (phase angle [°]) Rs (equivalent series resistance = ESR [Ω]) Rp (parallel resistance [Ω]) X (reluctance [Ω]) G (conductance [S]) B (susceptance [S]) Ls (series inductance [H]) Lp (parallel inductance [H]) Cs (series capacitance [F]) Cp (parallel capacitance [F]) Q...

 Open the catalog to page 2
LCR METER IM3523, IM3523A, IM3533-3

For Lead Components and Surface Mounted Devices (SMDs) Probes & Test Fixtures Please use the probes specified below. All probes are constructed with a 1.5D-2 V coaxial cable. Probes and Test Fixtures for Lead Components Cable length 1 m (3.28 ft), DC to 8 MHz, impedance characteristics of 50 Ω, 4-terminal pair configuration, measurable conductor diameter: ø0.3 mm (0.01 in) to ø5 mm (0.20 in) max. Direct connection type, DC to 8 MHz, measurable conductor diameter: ø0.3 mm (0.01 in) to ø2 mm (0.08 in) max. Cable length 1 m (3.28 ft), DC to 200 kHz, impedance characteristics of 50 Ω, 4-terminal...

 Open the catalog to page 3
LCR METER IM3523, IM3523A, IM3533-4

High-Speed, High-Accuracy, and Easy-to-Use Basic Performance ● Wide measurement frequency range The measurement frequency can be freely set to DC or any value in the 1 mHz (40 Hz for the IM3523, IM3523A) to 200 kHz range at high resolution (five-digit resolution [1 mHz resolution for less than 100 Hz]). This makes it possible to measure the resonant frequency and perform measurement and evaluation under conditions close to actual conditions. Measurement frequency[Hz] In addition to normal open-loop signal generation, these models enable voltage/current dependent measurement in constant voltage/...

 Open the catalog to page 4
LCR METER IM3523, IM3523A, IM3533-5

Features of LCR Meter Model IM3523, IM3523A Integration into Production Lines and Automated Machinery ● General specifications of the IM3523, IM3523A ● Easy setup using a numeric keypad on a simple, easyto-read monochrome LCD A simple user interface is provided with a high-contrast graphic LCD display, function keys, and numeric keypad. For numeric value settings such as the comparator setting, the numeric keypad can be used to enter numbers easily and quickly. Basic meaZ,Y,θ,Rs,Rp,X,G,B,Ls,Lp,Cs,Cp,Q,D surement items Rdc 3 Measurement items Transformer − measurement Temperature T − Basic accuracy...

 Open the catalog to page 5
LCR METER IM3523, IM3523A, IM3533-6

Features of LCR Meter Model IM3533 Winding, Coil and Transformer Production ● General specifications of the IM3533 Turn ratio N, mutual inductance M, and inductance difference ΔL can be measured on the transformer measurement screen. ● Rdc measurement with temperature compensation*2 For Rdc measurement of inductor and transformer windings, measurement can be performed while compensating for temperature. *2 Temperature Probe 9478 (option) is required for Rdc measurement with temperature compensation. ● Simultaneously display 4 parameters (for normal measurement) For normal measurement, four parameters...

 Open the catalog to page 6
LCR METER IM3523, IM3523A, IM3533-7

Features of LCR Meter Model IM3533-01 Research and Development and Electrochemistry ● General specifications of the IM3533 -01 Measurements can be performed automatically at up to 801 frequency points by specifying the frequency range or in the frequency list mode. The measurement results can be saved to a USB flash drive or to a computer via an interface, which then can be used to perform frequency analysis of samples. Basic measureZ,Y,θ,Rs,Rp,X,G,B,Ls,Lp,Cs,Cp,Q,D ment items Rdc 3 (with temperature compensation function) Measurement items Transformer N,M,Δ L measurement Temperature T 3 Basic...

 Open the catalog to page 7
LCR METER IM3523, IM3523A, IM3533-8

Capacitors and Inductors C-D + ESR Measurement of Capacitors Continuous measurement can be performed with high speed under multiple conditions! LCR mode [IM3523(A)] [IM3523(A)] Cs and D display screen (120 Hz measurement) Continuous measurement screen [IM3523(A)] [IM3523(A)] LCR mode [IM3523(A)] [IM3523(A)] Rs display screen (100 kHz measurement) C-D (120 Hz) and low ESR (100 kHz) measurement can be performed for functional polymer capacitors. Different measurement items can be measured continuously under different measurement conditions (frequency, level, and mode). C Measurement of Polar Capacitors...

 Open the catalog to page 8
LCR METER IM3523, IM3523A, IM3533-9

Transformer Winding and Sweep Measurements Variety of Transformer Winding Measurement Functions In addition to the L-Q and Rdc measurements, the IM3533 and IM3533-01 enable you to measure the turn ratio N, mutual inductance M, and inductance difference ΔL that are required for the measurement of transformers.* Connections must be switched manually or a selector such as a scanner unit is required separately. Turn ratio N measurement (1) Measure L (L1) on the primary side (2) Measure L (L2) on the secondary side (3) Calculate turn ratio N from L1 and L2 Transformer measurement mode Turn ratio measurement...

 Open the catalog to page 9
LCR METER IM3523, IM3523A, IM3533-10

Capturing Measurement Data ● Saving and loading data via front USB port Measurement results and settings can be saved to a commercially available USB flash drive connected to the front USB port. (The USB port on the front panel is specifically for a USB flash drive. Batch save all the measurement results to a USB flash drive after saving them to the internal memory of the IM3533(-01). Some USB flash drives may not be supported due to incompatibility issues.) Measurement results and settings Temperature sensor connection connector IM3523 rear panel ● Connecting to a PC via USB Save to USB flash...

 Open the catalog to page 10
*Prices are pre-tax. They exclude delivery charges and customs duties and do not include additional charges for installation or activation options. Prices are indicative only and may vary by country, with changes to the cost of raw materials and exchange rates.