Product catalog summary
Overview: The HIOKI LR5000 Series comprises compact data loggers for long-term recording of temperature, voltage, current, and instrumentation signals. These loggers feature expanded memory, user-friendly software, and the ability to continue recording during battery replacement.
Key Features:
  • Seven times the recording capacity of previous models.
  • Data import during recording and continuous measurement during battery replacement.
  • Intuitive PC software for data management and analysis.
  • Versatile applications including temperature, voltage, and current monitoring.
Applications:
  • Voltage Logger: Records pyranometer output for insulation evaluation.
  • Clamp Logger: Monitors current consumption in plants and buildings.
  • Instrumentation Logger: Records fluid flow and pressure sensor outputs.
  • Temperature/Humidity Logger: Manages environmental conditions in offices and factories.
Operation:
  1. Install the data logger and set the recording interval.
  2. Transfer data to a PC using USB or infrared communication.
  3. View and manage data using the bundled software.
Data Transfer and Storage:
  • Data can be transferred using a USB connection or an SD card.
  • Data Collector can import data from up to 16 data loggers.
  • Recording intervals range from 1 second to 60 minutes.
Advanced Features:
  • IP54 splash-proof rating for operation in humid environments.
  • Large internal memory with 60,000 data points per channel.
  • Statistical value recording mode captures detailed fluctuations.
  • Energy-efficient design with up to two years of battery life.
Software and Analysis:
  • LR5000 Utility program for data import and graph creation.
  • Supports data from previous HIOKI models.
  • Calculates maximum, minimum, and average values.
Specifications:
  • Communication Adapter and Data Collector support USB and infrared communication.
  • Operating temperature range: 0˚C to 40˚C.
  • Battery life varies by model and settings.
Product Models:
  • Humidity Logger LR5001: Records temperature and humidity.
  • Temperature Logger LR5011: Measures temperature with external sensors.
Accessories:
  • Magnetic Strap, Wall-mounted Holder, and various sensors available.
Product Overview: The document details specifications for HIOKI products, including the Clamp Logger LR5051, Instrumentation Logger LR5031, and Voltage Loggers LR5041, LR5042, and LR5043, designed for recording electrical parameters such as load current, leak current, and instrumentation signals.
Clamp Logger LR5051:
  • Features: Records load and leak currents at 50Hz/60Hz with AC current measurement across two channels.
  • Measurement Range: Varies depending on the sensor used, ranging from 500.0mA to 1000A.
  • Accuracy: ±0.5% reading ±5 digits plus clamp sensor accuracy.
  • Operating Conditions: Not waterproof, operates between 0˚C to 50˚C with up to 80% relative humidity.
  • Power Supply: Two LR6 (AA) alkaline batteries.
  • Battery Life: Approximately 1 year with 1-minute recording intervals.
Instrumentation Logger LR5031 and Voltage Loggers LR5041, LR5042, LR5043:
  • Features: Designed for recording 4-20 mA instrumentation signals and measuring analog outputs.
  • Measurement Range: DC current from -30.00 to 30.00mA and voltage ranges depending on the model.
  • Accuracy: ±0.5% reading ±5 digits at 23˚C ±5˚C.
  • Waterproof Rating: IP54 splash-proof construction.
  • Operating Conditions: Operates between -20˚C to 70˚C with up to 80% relative humidity.
  • Power Supply: One LR6 (AA) alkaline battery.
  • Battery Life: Approximately 2 years with 1-minute recording intervals.
Clamp Sensors:
  • Models: 9669, CT6500, 9695-02, 9675, 9657-10.
  • Primary Current Ratings: Range from 10A to 1000A AC.
  • Accuracy: Varies by model, generally around ±1.0% reading.
  • Maximum Rated Voltage: Up to 600Vrms for insulated conductors.
  • Dimensions and Mass: Vary by model, with specific dimensions and weights provided.
Additional Information: Specifications are subject to change without notice. Optional accessories like the LR5091 Communication Adapter or LR5092-20 Data Collector are needed for data analysis on a PC. Connection cords are sold separately, and contact information for HIOKI offices worldwide is provided.
See more

Catalog excerpts

TEMPERATURE LOGGER LR5011-1

Complete Line of Easy-to-Use Compact Loggers with Expanded Memory The new HIOKI compact data logger series easily records temperature, voltage. current, and instrumentation signals over long periods. Carried over from its highly reputed predecessor, this series includes features and functions such as 7 times the recording capacity of former models, data import during recording, continuous measurement even during battery replacement, and intuitive PC soft- ware. Flexible and easy-to-use at single and multiple locations, the new HIOKI compact data logger series is ideal for any application that requires simple set-up but long-term, reliable recording capabilities. HIOKI company overview, new products, environmental considerations and other Information are available on our website.

 Open the catalog to page 1
TEMPERATURE LOGGER LR5011-2

Meet a Wide Variety of Data Logging Applications Temperature Logger /Humidity Logger Manage the temperature and humidity in offices and factories. Visually monitor the data to save on airconditioning and heating costs. Instrumentation Logger / Voltage Logger Record fluid flow such as for water, gas and oil. Measure flow meter output signals to monitor flow trends. Clamp Logger Manage the current consumption of plant and building equipment. Visually monitor power costs to efficiently conduct energyand cost-saving activities. Use as a Voltage Logger to record pyranometer output for evaluating insulation....

 Open the catalog to page 2
TEMPERATURE LOGGER LR5011-3

Easy operation in just Install a Data Logger, set an interval, and start measuring. Easy to start recording Unlimited installation capabilities Wall-mounted Holder (sold separately) Not usable with LR5051 Set your recording interval. (from one second to 60 minutes) Download data using infrared communication. Transfer data from Data Logger to PC Kickstand (included, except for Model LR5051) Grab the Data Logger from the worksite and connect to a PC. Retrieving the Data Logger Transfer data from Data Logger to PC using a USB connection Using the Data Collector's internal memory, import data from...

 Open the catalog to page 3
TEMPERATURE LOGGER LR5011-4

Advanced Features and Functions Install Almost Anywhere Recording capacity up to 7 times previous models Easily mount the light-weight, pocket-sized loggers in tight spaces. Large internal memory stores 60,000 data points per channel. Long-term recording capability exceeds that of previous models. Interval times 1s 2s 5s 10s 15s 20s 30s 1m 2m 5m 10m 15m 20m 30m 60m Actual size Easy-to-see dual display Temperature and humidity or current channels can be displayed. View maximum and minimum values while measuring. Moist environments The maximum recording time depends on battery life. The battery...

 Open the catalog to page 4
TEMPERATURE LOGGER LR5011-5

Bundled Software Ensures Smooth and Easy Data Analysis i Import data to a PC and create graphs Use the LR5000 Utility program to import Data Logger data to a PC to make graphs and analyze data further. Easily print results using your PC. ilflttnl UflHt aittfi */tl*l «*Mi 0M*»i mini oHfll mw nnn: mam «.m>ii miUf< m.uiti a.vni o.*li n-n.ii I Show specific values using the cursor function Use the A/B cursors to select any location on a graph and display its value. The PC software can also calculate maximum, minimum, and average values between A and B cursors. j Simple file aggregation and management...

 Open the catalog to page 5
TEMPERATURE LOGGER LR5011-6

Communication Adapter and Data Collector Specifications (Product guaranteed for one year) Physical appearance Data Collector LR5092-20 •Collect recorded data from the Data Logger to internal memory or SD card •View collected data in a graph •Transfer data from a Data logger to a PC •Transfer Data Logger configurations or clock settings from internal •Transfer Data Logger configurations or clock settings from a PC memory or SD card to the Data Logger •Transfer data from a Data Logger to a PC to the Data Logger •Transfer Data Logger configurations or clock settings from a PC to the Data Logger...

 Open the catalog to page 6
TEMPERATURE LOGGER LR5011-7

See page 6 for Common specifications (Product and accuracy guaranteed for one year) Physical appearance *Sensor is sold separately. Temperature and humidity are recorded simultaneously using supplied or optional temperature and humidity sensors. Temperature 1ch and Humidity 1ch Measurement items Measurement range Temperature measurement with external temperature sensor. Select the sensor according to the measurement object * Values provided for reference only. Waterproof and dustproof performance Operating temperature and humidity Dimensions & Mass Power supply IP54 (splash-proof construction)...

 Open the catalog to page 7
TEMPERATURE LOGGER LR5011-8

Product Specifications See page 6 for Common specifications (Product and accuracy guaranteed for one year) For recording 4-20 mA instrumentation signals, etc. Measurement items Measurement range Voltage Logger LR5041, LR5042, LR5043 For recording instrumentation signals and measuring analog outputs from sensors and other devices DC voltage 1ch ±0.5%rdg. ±5dgt. (@23˚C±5˚C) ±0.5%rdg. ±5dgt. (@23˚C±5˚C) Accuracy Waterproof and IP54 (splash-proof construction) dustproof performance Operating temperature -20˚C(-4˚F) to 70˚C(158˚F) , 80%rh or less (non-condensating) and humidity Approx. 79mm(3.11in)W×57mm(2.24in)H×28mm(1.10in)D,...

 Open the catalog to page 8

All HIOKI E.E. CORPORATION catalogs and technical brochures

*Prices are pre-tax. They exclude delivery charges and customs duties and do not include additional charges for installation or activation options. Prices are indicative only and may vary by country, with changes to the cost of raw materials and exchange rates.