Complete Line of Easy-to-Use Compact Loggers with Expanded Memory The new HIOKI compact data logger series easily records temperature, voltage. current, and instrumentation signals over long periods. Carried over from its highly reputed predecessor, this series includes features and functions such as 7 times the recording capacity of former models, data import during recording, continuous measurement even during battery replacement, and intuitive PC soft- ware. Flexible and easy-to-use at single and multiple locations, the new HIOKI compact data logger series is ideal for any application that requires simple set-up but long-term, reliable recording capabilities. HIOKI company overview, new products, environmental considerations and other Information are available on our website.
Open the catalog to page 1Meet a Wide Variety of Data Logging Applications Temperature Logger /Humidity Logger Manage the temperature and humidity in offices and factories. Visually monitor the data to save on airconditioning and heating costs. Instrumentation Logger / Voltage Logger Record fluid flow such as for water, gas and oil. Measure flow meter output signals to monitor flow trends. Clamp Logger Manage the current consumption of plant and building equipment. Visually monitor power costs to efficiently conduct energyand cost-saving activities. Use as a Voltage Logger to record pyranometer output for evaluating insulation....
Open the catalog to page 2Easy operation in just Install a Data Logger, set an interval, and start measuring. Easy to start recording Unlimited installation capabilities Wall-mounted Holder (sold separately) Not usable with LR5051 Set your recording interval. (from one second to 60 minutes) Download data using infrared communication. Transfer data from Data Logger to PC Kickstand (included, except for Model LR5051) Grab the Data Logger from the worksite and connect to a PC. Retrieving the Data Logger Transfer data from Data Logger to PC using a USB connection Using the Data Collector's internal memory, import data from...
Open the catalog to page 3Advanced Features and Functions Install Almost Anywhere Recording capacity up to 7 times previous models Easily mount the light-weight, pocket-sized loggers in tight spaces. Large internal memory stores 60,000 data points per channel. Long-term recording capability exceeds that of previous models. Interval times 1s 2s 5s 10s 15s 20s 30s 1m 2m 5m 10m 15m 20m 30m 60m Actual size Easy-to-see dual display Temperature and humidity or current channels can be displayed. View maximum and minimum values while measuring. Moist environments The maximum recording time depends on battery life. The battery...
Open the catalog to page 4Bundled Software Ensures Smooth and Easy Data Analysis i Import data to a PC and create graphs Use the LR5000 Utility program to import Data Logger data to a PC to make graphs and analyze data further. Easily print results using your PC. ilflttnl UflHt aittfi */tl*l «*Mi 0M*»i mini oHfll mw nnn: mam «.m>ii miUf< m.uiti a.vni o.*li n-n.ii I Show specific values using the cursor function Use the A/B cursors to select any location on a graph and display its value. The PC software can also calculate maximum, minimum, and average values between A and B cursors. j Simple file aggregation and management...
Open the catalog to page 5Communication Adapter and Data Collector Specifications (Product guaranteed for one year) Physical appearance Data Collector LR5092-20 •Collect recorded data from the Data Logger to internal memory or SD card •View collected data in a graph •Transfer data from a Data logger to a PC •Transfer Data Logger configurations or clock settings from internal •Transfer Data Logger configurations or clock settings from a PC memory or SD card to the Data Logger •Transfer data from a Data Logger to a PC to the Data Logger •Transfer Data Logger configurations or clock settings from a PC to the Data Logger...
Open the catalog to page 6See page 6 for Common specifications (Product and accuracy guaranteed for one year) Physical appearance *Sensor is sold separately. Temperature and humidity are recorded simultaneously using supplied or optional temperature and humidity sensors. Temperature 1ch and Humidity 1ch Measurement items Measurement range Temperature measurement with external temperature sensor. Select the sensor according to the measurement object * Values provided for reference only. Waterproof and dustproof performance Operating temperature and humidity Dimensions & Mass Power supply IP54 (splash-proof construction)...
Open the catalog to page 7Product Specifications See page 6 for Common specifications (Product and accuracy guaranteed for one year) For recording 4-20 mA instrumentation signals, etc. Measurement items Measurement range Voltage Logger LR5041, LR5042, LR5043 For recording instrumentation signals and measuring analog outputs from sensors and other devices DC voltage 1ch ±0.5%rdg. ±5dgt. (@23˚C±5˚C) ±0.5%rdg. ±5dgt. (@23˚C±5˚C) Accuracy Waterproof and IP54 (splash-proof construction) dustproof performance Operating temperature -20˚C(-4˚F) to 70˚C(158˚F) , 80%rh or less (non-condensating) and humidity Approx. 79mm(3.11in)W×57mm(2.24in)H×28mm(1.10in)D,...
Open the catalog to page 816 Pages
20 Pages
12 Pages
12 Pages
108 Pages
8 Pages
12 Pages
80 Pages
2 Pages
12 Pages
2 Pages
4 Pages
16 Pages
14 Pages
4 Pages
8 Pages
2 Pages
12 Pages