HIOKI ST5540/ST5541 LEAK CURRENT HiTESTER
8Pages

{{requestButtons}}

Catalog excerpts

HIOKI ST5540/ST5541 LEAK CURRENT HiTESTER - 1

A/ewJ LEAK CURRENT HiTESTER ST5540/ST5541 Safety standards measuring instruments Leak Current Measurement - Essential to Electrical Safety Introducing a leak current measuring instrument that complies with the IEC 60601-1 standard (3rd edition, with the ST5540), the ST5540 series feature an improved measuring method and dramatically faster cycle times, thanks to its uninterrupted polarity switching. The new devices support rated currents of up to 20A, making it more than ideal for use with products built to new standards. /www.hioki.com ) HIOKI company overview, new products, environmental considrations and other information are available on our website. ISO 9001 ISO14001 JMI-0216 JQA-E-90091

Open the catalog to page 1
HIOKI ST5540/ST5541 LEAK CURRENT HiTESTER - 2

2 Mdical Electrical Devices IEC 60601-1:(2005)3rd Edition-compliant ST5540 Complies with all standards (suitable for use with all networks) Leak current parameters as defined for medical-use electrical devices include ground leak current, contact current, patient leak Some examples of the standards with which the instrument complies are listed below. The ST5540 can be used with all standards that apply to the networks in which it is used. current, and patient measurement current. The ST5540 provides a single solution for measuring all of thse leak current variants. In order to prevent the...

Open the catalog to page 2
HIOKI ST5540/ST5541 LEAK CURRENT HiTESTER - 3

3 For Standard- and Regulation-compliance Measurement of General-use Electrical Devices ST5541 There are various standards in place concerning networks (body simulated resistance), and a standard-compliant network is required in order to make measurements. ST5541 provides standard support for standard-compliant networks (excluding medical-use electrical devices). A single, robust solution

Open the catalog to page 3
HIOKI ST5540/ST5541 LEAK CURRENT HiTESTER - 4

4 ST5540/ST5541 Features ■Uninterrupted polarity switching function The ability to conduct tests without turning off the power when switching the power supply polarity dramatically reduces cycle times. The ST5540/ST5541 can switch polarity without stopping the supply of power to the device under measurement (patent pending). Old models require that the device under measurement be turned off and then back on again when switching polarity, but the ST5540 and ST5541 let you progress smoothly to the next testing process. ■Improved test reliability Blown fuse check function When measurement...

Open the catalog to page 4
HIOKI ST5540/ST5541 LEAK CURRENT HiTESTER - 5

5 Expandability for the Future ly ■All the switch terminais needed for standard-compliant measurement The ST5540/ST5541 provides the terminais needed to perform leak current measurement in compliance with IEC 60601-1, eliminating the need for the user to provide external switches Connection terminals S10 terminal : Switch for connecting a function ground terminal to the measurement power supply system's ground point Allows connectivity to ground to be configured during leak current measurement 512 terminal : Switch for connecting the parts of device that come into contact with the patient...

Open the catalog to page 5
HIOKI ST5540/ST5541 LEAK CURRENT HiTESTER - 6

2012 less'n'more Gesamtkatalog web.indd table.main {} tr.row {} td.cell {} div.block {} div.paragraph {} .font0 { font:2.65pt "Lucida Sans Unicode", sans-serif; } .font1 { font:3.60pt "Lucida Sans Unicode", sans-serif; } .font2 { font:4.00pt "Lucida Sans Unicode", sans-serif; } .font3 { font:6.00pt "Lucida Sans Unicode", sans-serif; } .font4 { font:7.00pt "Lucida Sans Unicode", sans-serif; } .font5 { font:10.00pt "Lucida Sans Unicode", sans-serif; } .font6 { font:4.80pt "Times New Roman", serif; } .font7 { font:5.00pt "Times New Roman", serif; } .font8 { font:7.00pt "Times New Roman",...

Open the catalog to page 6
HIOKI ST5540/ST5541 LEAK CURRENT HiTESTER - 7

7 Safety Standard for Hospital Electrical Equipment JIS T 1022:2006 Measurement 3157 Main ground line Medical ground center Ground branch line ■Measuring between the grounding center and grounding terminal Verify that the electrical rsistance between the medical outlet's grounding electrode connector or medical ground terminal and medical ground center is less than or equal to 0.1 Q by applying a current of approximately 25 A with an AC current with a no-load voltage of 6 V or less and measuring the resistance using the voltage droop method. *This measurement requires an extension cable...

Open the catalog to page 7
HIOKI ST5540/ST5541 LEAK CURRENT HiTESTER - 8

8 PRINTER 9442 Convenience The optional PRINTER 9442 can be used to print data via the instrumenta RS-232C interface, providing a convenient way to attach a hard copy of test data. 0^ Print method: Thermal serial dot Paper width/print speed: 112 mm/52.5 cps Power supply: AC ADAPTER 9443 or included nickel-metal-hydride battery (good for approx. 3,000 lines of print when fully charged with the 9443 adapter) Dimensions: Approx. 160 (W) x 66.5 (H) x 170 (D) mm Weight: Approx. 580 g Printable data (printed data can be selected from the following) Measurement date ՕAllowable values Instrument...

Open the catalog to page 8