Signal Source & Calibrator I^SU Improved stability and lower calibration costs Conduct loop testing of Validate thermostatic devices and generator for production facilities maintenance and electronic device DC fignal Source Supplies and Measures Signals Simultaneously The HIOKI DC SIGNAL SOURCE SS7012 can be used not only for instru- mentation system (4-20 mA) maintenance, but also for maintaining and servicing thermostatic devices, distributors, and industrial meters, as well as for evaluating electronic circuits and devices, and for production facility maintenance. The signal source also supplies thermoelectromotive force corresponding to eight types of thermocouples. Furthermore, this compact DC signal source simultane- ously sources and measures signals. HIOKI company overview, new products, environmental considerations and other Information are available on our website.
Open the catalog to page 1Use as A Hand-Held Field Calibrator for Loop Testing of Instrumentation Systems, and for Production Facility Maintenance • Eight thermoelectromotive force sourcing (TC) • TEMP measurement from -25 to 80°C • Improved stability and lower calibration costs • Control from a PC via USB connection # Loop test (two-wire transmitter sensor) Verifies proper sensor output (two-wire transmitter sensors). The SS7012 applies distributor power to the sensor as a constant- voltage (C V) output, and monitors current output from the sensor. • Example applications • Instrumentation system loop testing (4-20 mA)...
Open the catalog to page 2Use as A Signal Source for Production Facility Maintenance, plus Electronic Device Testing and # Simultaneous voltage and current Source up to ±25.000 V and ±25.000 mA while measuring up to ±28.000 V and ±28.000 mA. Isolated source and measurement circuits can increase operating efficiency for applications such as simultaneous input and output testing of transducers using a single instrument. Electronic Circuit or Device • Small source applications Use as a portable signal source for electronic device testing and evaluation. Full external control is available via the USB inter- Only for communicating...
Open the catalog to page 3(At 23 ±5°C, accuracy guaranteed for one year) Measurement Range Thermocouple types, source range Memory Sourcing (RECALL, SCAN) One type for each function: CV2.5, Load current monitor Terminal voltage monitor Reference contact temperature monitor (after zero adjustment) (after zero adjustment) Input Resistance Input Resistance * Including approximately 15 Cl fuse resistance AC ADAPTER CARRYING CASE CARRYING CASE COMMUNICATION INPUT CORD TEST LEAD TEMPERATURE Source output method: Bipolar sink/source A/D conversion method: Delta-Sigma Temperature coefficients (sourcing): Temperature coefficients...
Open the catalog to page 416 Pages
20 Pages
12 Pages
8 Pages
12 Pages
108 Pages
8 Pages
12 Pages
80 Pages
2 Pages
12 Pages
2 Pages
4 Pages
16 Pages
14 Pages
4 Pages
8 Pages
2 Pages
12 Pages