video corpo

HIOKI Field Measuring Instruments catalog (2014)
40Pages

{{requestButtons}}

Catalog excerpts

HIOKI Field Measuring Instruments catalog (2014) - 1

Field Measuring Instruments Solutions for Maintenance, Repair and Operations

Open the catalog to page 1
HIOKI Field Measuring Instruments catalog (2014) - 2

Electrical Measuring Instruments from Shinshu Ueda This year, HIOKI is celebrating the 78th anniversary of our founding in 1935. Going forward, we remain committed to developing professional tools for electrical measurement that deliver the solutions customers need. All development, production, sales, and service departments are based at our Head Office and manufacturing facilities in the lush region of Shinshu Ueda. By keeping the full range of development and production work inhouse, we are able to meet customer needs with unparalleled speed. SOLUTION FACTORY With all operations...

Open the catalog to page 2
HIOKI Field Measuring Instruments catalog (2014) - 3

Field Measuring Clamp Meters Clamp Meters Insulation Testers Insulation Testers Other testing equipment Earth testers, Voltage detectors, Phase detectors Other testing equipment Environmental Measuring Environmental Measuring Temperature Testers Temperature Testers Other testing equipment Signal Generator, Battery Testers Signal Generator, Battery Testers Data Loggers Data Loggers Power Meters Power Meters Memory Recorders Memory Recorders Other testing equipment Other testing equipment Field Measuring Other testing equipment Magnetic field testers, Sound/ Lux/ Rotation testers

Open the catalog to page 3
HIOKI Field Measuring Instruments catalog (2014) - 4

l This catalog provides an overview of carefully selected product specifications with a focus on field measuring instruments. For more information, please see individual product catalogs or HIOKI’s website. l How to search for products This catalog is designed to make it easy to find the product you’re looking for. Use the table of contents at the beginning (p.3) to search by category. l Dimensions and mass Exterior dimensions exclude protrusions, and are given in order of width(W), height(H), and depth(D), in mm units. Indicated weight represents an approximation of the mass of the main...

Open the catalog to page 4
HIOKI Field Measuring Instruments catalog (2014) - 5

There are two methods for converting current into RMS values: the true RMS method (true RMS value indication) and the mean method (mean rectification RMS value indication). Although both methods yield the same value for undistorted sine waves, distortion of the waveform causes the values to diverge. RMS value method (true RMS value indication) The waveform including harmonic components is calculated according to an RMS calculation formula and displayed. distorted current values from an inverter, etc. Mean method (mean rectification RMS value indication) True RMS clamp ammeter The input...

Open the catalog to page 5
HIOKI Field Measuring Instruments catalog (2014) - 6

Robust tools for the field. HIOKI’s measuring instruments have evolved as we work to ensure they can be used even in harsh environments by constantly improving their toughness, durability and reliability. Rigorous Testing on All Products Drop test (destructive test) We evaluate the drop impact and increase product drop resistance. The product is subjected to freefall conditions from a height of 1 m repeatedly so that it lands on each of its six surfaces in turn. Testing continues at increasingly greater heights until the product is destroyed. We test how well the product can resist...

Open the catalog to page 6
HIOKI Field Measuring Instruments catalog (2014) - 7

Basic tester with improved safety features (20kΩ/V) Sleeve attached ■ Basic specifications (Accuracy guaranteed for 1 year) New insulated test pin sleeves prevents short-circuits Spare fuse HIGH-VOLTAGE R6P manganese PROBE 9017 battery×2 (Not CE marked) Instruction manual MULTI TESTER 3008 Drop-proof & simple dust-proof design Suitable for use on industrial power lines (20kΩ/V) ■ Basic specifications (Accuracy guaranteed for 1 year) *The 9060 has a shortened metal tip for safety reasons. Carring case Spare fuse Manganese batteries (R6P) ×2 Instruction manual 0 to 12/30/120/300/600 V ±2.5 %...

Open the catalog to page 7
HIOKI Field Measuring Instruments catalog (2014) - 8

POCKET/HANDHELD CARD HiTESTER 3244-60 SOLAR HiTESTER 3245-60 Sleeve attached Sleeve attached Compact, palm-sized body less than 1cm thin AC/DC 42MΩ 500V Continuity check AC/DC 42MΩ 600V Continuity check Carrying case Sleeves Note: When measuring in a CAT III environment, be sure to attach the sleeve to the test leads. Note: When measuring in a CAT IV or CAT III environment, be sure to attach the sleeve to the test leads. Sleeve attached Pencil-type DMM with LED light Sleeves Instruction manual Coin type litium battery (CR2032) Instruction manual Coin type litium battery (CR2032) Extra...

Open the catalog to page 8
HIOKI Field Measuring Instruments catalog (2014) - 9

Maximum display count Display backlight function Basic specifications Probe sleeve attached CAT No probe sleeve attached Measurement range AC/DC voltage AC/DC current (Direct input) AC current (Clamp sensor) 10.00 A to 1000 A (with optional clamp sensor) Continuity buzzer Diode check Temperature (thermocouples) Functions Auto power save Range switching Auto only Auto/ Manual Auto/ Manual Auto/ Manual Auto/ Manual Refresh hold (HOLD AUTO) Sampling rate Other functions Power supply Light check Sleeve attached No sleeve attached LED light illuminates test points LCD backlight Main power...

Open the catalog to page 9
HIOKI Field Measuring Instruments catalog (2014) - 10

DIGITAL MULTIMETER DT4280 Series Speedy Performance of Professional Testing The DT4200 DMM Series Deliver Safety and Quick Measurement Response Sleeve attached DT4281: High-End model (for electrical work and inverters) ˚C AC/DC AC/DC AC clamp 600MΩ Capacitance 500kHz 1000V 600mA 1000A* Continuity check 100.0mF Frequency -40 to 800 630Hz low-pass filter cuts harmonics, ideal for inverter testing *with optional sensors DT4282: High-End model (for R&D and Laboratories) ˚C AC/DC AC/DC 600MΩ Capacitance 500kHz 1000V 10A Continuity check 100.0mF Frequency -40 to 800 DIGITAL MULTIMETER DT4250...

Open the catalog to page 10
HIOKI Field Measuring Instruments catalog (2014) - 11

*For more detailed information, please refer to the individual product catalogs. High-end models Standard models Pocket models Electrical work/ inverters Electrical work HVAC/ instrumentation Electrical work Basic specifications Principal applications AC measurement system Maximum display count Display backlight function Probe sleeve attached No probe sleeve attached Measurement range CAT Accuracy AC/DC current (Direct input) ±0.6% rdg. ±5 dgt. Accuracy (AC A) N/A AC current (Clamp sensor) 10.00 A to 1000 A N/A Accuracy ±0.6% rdg. ±2 dgt.*1 60.000 Ω 600.00 Ω 6.0000 kΩ 60.000 kΩ Resistance...

Open the catalog to page 11

All HIOKI E.E. CORPORATION catalogs and technical brochures