Product catalog summary
Overview
The MEMORY HiLOGGER Model 8423 is a high-speed data acquisition system designed for efficient measurement and recording across multiple channels. It is particularly suited for environments requiring rapid data sampling and numerous measurement channels.

Specifications
- Fastest measurement interval: 10 ms
- Supports up to 600 channels
- Insulation withstand voltage: 200 V between channels, 600 V to earth
- Expandable to 120 channels per instrument, with up to five instruments connected

Applications
- Electric and hybrid vehicle development
- Temperature distribution measurement in air conditioning systems
- Voltage measurement of individual cells in battery stacks

Design and Usability
- Removable terminal blocks for easy connection
- Configuration via PC application
- Supports DIN rail mounting and easy module addition

Data Management
- Real-time data recording to CF Card
- Dual sampling capability
- Enhanced data protection against power failures
- USB and LAN connectivity for data transfer and control

Functional Details
- Universal isolated inputs for temperature, voltage, and pulses
- Supports various input modules
- External control inputs for triggering and sampling
- Enhanced noise immunity with delta-sigma A/D converter

Trigger and Alarm Functions
- Multiple trigger modes including level, window, and logic pattern
- Alarm outputs with latch settings

PC Interface
- Data storage on CF cards up to 1 GB
- LAN and USB interfaces for PC control and data acquisition

Product Specifications
- LCD display with 16 characters x 2 lines
- Memory capacity of 16 M-word

Additional Specifications
- Voltage Levels: High is at least 1.0 V or 4.0 V, Low ranges from 0 to 0.5 V or 0 to 1.5 V
- Pulse Input Period: 200 μs or more with filter off, 100 ms or more with filter on
- Chatter-prevention filter can be set on/off for each channel
- Rising or falling edge slope detection for each channel

Configuration and Models
- Input Units: Configurations of 15, 30, 60, 120, 240, 480, and 600 isolated channels
- Models: Includes Model 8423, Model 8948, Model 8996, Model 8997, and Model 8949
- Synchronization: Uses synchronization cables for connecting multiple units

Options and Accessories
- LAN Cable: Ethernet cable with straight to cross conversion, 5 m length
- Connection Cable: For synchronization, 1.5 m length
- Humidity Sensor: 1-channel for Universal Unit 8949
- AC Adapter: Universal 100 to 240 V AC, 12 V DC/2.5 A output
- PC Cards: Available in 1 GB, 512 MB, and 256 MB capacities

Important Notes
- Model 8423 requires optional input modules
- Thermocouples must be purchased separately
- Use only PC Cards sold by HIOKI for compatibility and performance
See more

Catalog excerpts

HIOKI 8423 MEMORY HiLOGGER Series-1

HIOKI MEMORY HiLOGGER 8423 Fast 10-ms Sampling Up to 600 Channels Data Logging MEMORY HiLOGGER Model 8423 is a data acquisition System capable of measuring and recording multiple channels at hgh speed. Acquired data can be easily analyzed on a personal computer. This model is idal for acquiring data for valuation and testing al development sites. If your valuation needs require faster data sampling than was available with former HIOKI MEMORY HiLOGGERs. or if you just need more measurement channels, this mode! has ihe capabilities you want. www-hiokJ.com ; ISO 9001 ISO14001

 Open the catalog to page 1
HIOKI 8423 MEMORY HiLOGGER Series-2

2 Whoneeds10mshigh-speedsamalin -Answer- To acquire data when converting automobile electronics for electric or hybrd vehicles Fastest measurement interval (sampling interval) is 10 ms  Acquires up to 600 channels of data with 10 ms sampling interval Insulation withstand voltage between the measurement channels in each module is 200 V (Model 8948) ^^^^^ In the development of electric and hybrid automobiles, Ihe nccd to capture sudden swings in various loads requircs a measurement instrument with mulit chaunel high speed sampling capabihty. For this purpose, HIOKI has developed a very economical...

 Open the catalog to page 2
HIOKI 8423 MEMORY HiLOGGER Series-3

Who needs 121 - Answe To acquire multi-point temprature distribution data I 1 H I oltage of each cell in a stac Expandable up to 120 channels with a single instrument 镕 Up to five instruments can be connected for measuring up to 600 channels Isolated to sustain up to 600 V between modules and earth Tempթrature distribution is measured to evaluate air conditioning Systems during development. A system to acquire data on up to 600 channels can be constructed with merely a LAN or USB connection, providing highly detailed temperature distribution measurements. With all channels isolated and a 600V...

 Open the catalog to page 3
HIOKI 8423 MEMORY HiLOGGER Series-4

"Simplicity" as a Design Concept Installation Because the terminal blocks are designed to be removable, thermocouples can be connected to the terminal block in hand before connecting the block to a HiLOGGER input module, with just one touch. Easily add input modules: just align and mate the connectors on the left side of the instrument assembly, and turn the metal clasp. For added strength, attach the supplied mounting bracket on the rear, or attach a standard DIN rail to the rear for tray or rack mounting. Each measurement module daisy-chains onto the stacking configuration. Mounting with a...

 Open the catalog to page 4
HIOKI 8423 MEMORY HiLOGGER Series-5

5 3 l3. View your data even while measuring! Data is recorded on the computer in real time using the supplied Logger Utility PC application program. View a trend graph in a window and scroll back to view earlier waveform data, even while recording. Post-measurement analysis (New Double-Thumb function*) The newly developed Double-Thumb function simplifies analysis. Two windows are displayed side by side, each with a scroll bar at the bottom containing a thumb (scroll box) that corresponds to the length and position of that window's displayed segment within the overall waveform. The thumbs in the...

 Open the catalog to page 5
HIOKI 8423 MEMORY HiLOGGER Series-6

6 More Functional Dtails Universal isolated inputs for temprature, voltage and puises *1 Pt (platinum r驩sistance temprature sensor) and humidity measurements require «2 Requires optional HUMIDITY SENSOR 9701 UNIVERSAL UNIT 8949 With the modular input design, you can select the input modules appropriate for your measurement application. Select from voltage and temperature (thermocouple or Pt input«1) and humidity.«1 «2 Also, Digital Pulse Module 8996 provides 15 input channels for totalization/ rotation counts and Hi/Lo logic measurements. In addition to inter-channel input isolation, the PC connection...

 Open the catalog to page 6
HIOKI 8423 MEMORY HiLOGGER Series-7

7 Dual Sampling Two diffrent measurement intervais can be specified at the same time (one interval setting per input module). Using dual sampling, the appropriate measurement interval can be set for each type of object to be measured, optimizing use of internal memory and CF Card capacity. Logging lAnaloq 4& 1-2-1 [°C]| '07-05 '07-05 '07-05' '07-05 '07-05 '07-05 '07-05 '07-05 '07-05' '07-05 '07-05 '07-05 1-1-2 [V]| 1-1-3 [V]| 23 14 23 14 23 14 23 14 23 14 23 14 23 14 23 14 ■23 14 23 14 23 14 23 14 34:22.2s 34:22.35 34:22.4s 34:22.5s 34:22.6s 34:22.7s 34:22.8s 34:22.9s 34:23.0s 34:23.1s 34:23.2s...

 Open the catalog to page 7
HIOKI 8423 MEMORY HiLOGGER Series-8

8 More Functional Dtails All-Channel Synchronous Measurement Capability When measuring up to 120 channels on combined modules, all input channels are sampled synchronously. When multiple 8423s are connected via LAN or USB for measuring up to 600 channels, the sampling of each instrument in the system can be synchronized using optional Connection Cable Model 9683. As well as PC-based data collection, measurement start and stop can be controlled by the [START/MARK] and [STOP] keys on a master 8423. Note: Any 8423 may be designated as the master. Only the initial acquisition criteria setting needs...

 Open the catalog to page 8
HIOKI 8423 MEMORY HiLOGGER Series-9

S Product Spcifications 8423 Hardware Spcifications ^k««H4:i.yc^>KBNui«» Disptay I.CD. 16 ctuiartni - 2 une», b- S drfi." ehaiactei* Momory c apaot y Toul 16 M *wd ml Ext驻mal c ont roi connectors FMi<^h*fir<* typ* itfotiQftl Noet hitrnuJ mj^i.1 Litiuil uupuag inpfl 0k>t L* Terni «in nput, Liitnul Hop inpui LiirrMl umpnj; : rue up. m UIJ down prJretitlr) R»s^;OT<0tDll)V)»HiEbCito5frVj lilUtown: H:eb-:?i*<j JiV-to tjtv (0^ I 0 V).CT tmauul ihvi Ispatohjp-rnp: >to 10VDCFilietQNOITpou怒fc Puiw vidtfc npM : Ow l nu il *H\ owct 2 i* al *L" <* flntt OrT)h Over 2 S nu at *K".om4iu«t'L'QIOtoON) \i\imu[E...

 Open the catalog to page 9
HIOKI 8423 MEMORY HiLOGGER Series-10

10 Spcification Bundled software spcifications Data conversion lafmut iftWidm <MFM farnu驯t Ihdn pcvruinf diu Caamttd ttrtidav AlldjiA JrMj%it>^i tcfuod Iwmtf: CS\' tatui (vfwiir trt «mmip". t*). to DES* ; i - ■! ■ rrrt jit*t> dXJ fW*""*f catcutaboro TftiEftdjU: Rf*i aov dia kifuincvi (ItJV Rncrdi? tmtLtvmAe nmto of ON rair jriOtf ta». s>i>^: Jr»i»t>^i Search fundion T*rf»< 4tf*:Rf*Mnir xquiura flic (HTtfc*). R«a4lo Sf ji ch modr: iiuil hmr ukl d^r tta^tn tm pju^ti Inri nvdcw. nutr^u ofrhx-gc Print function Suppartfd pnotd : jrintrr ronpuibtr v.uh ٻr OS 141 fH Ama: Rri] tof 4*a jrqmabcQ k (LITW...

 Open the catalog to page 10

All HIOKI E.E. CORPORATION catalogs and technical brochures

*Prices are pre-tax. They exclude delivery charges and customs duties and do not include additional charges for installation or activation options. Prices are indicative only and may vary by country, with changes to the cost of raw materials and exchange rates.