Catalog excerpts
Safety Standards Measuring Instruments HIOKI 3157 AC QHOUNDiwa H TESTER CE certified low-resistance measurement compliant with major safety standards Protective ground tester indispensable for standard certification The AC GROUNDING HiTESTER 3157-01 is designed to measure whether the metal enclosure of an electrical equipment is connected to the ground terminal at sufficiently low resistance levels. It also can be used to evaluate the grounding conditions of large-scale electrical installations. Measurement is carried out by using a high current according to the specifications of the measurement object, and determining the voltage drop at the measurement point. Reference values are as set out in the various safety standards. The 3157-01 can carry out measurements in accordance with the stipulations of multiple HIOKI company overview, new products, environmental considerations and other information are available on our website.
Open the catalog to page 11 Low-resistance measurements in accordance with all major safety standards Main applications The 3157-01 passes a large AC current through the measurement object and measures the voltage drop according to the AC 4-terminal method, making it possible to measure very low resistance values. ● Protective grounding checks of medical and general electrical equipment ● Ground connection tracing of machine tools and wiring panels ● Safeguard and equal-potential connection checks of medical installations ● High-current behavior evaluation of connections Major features ■ Compliant with a multitude...
Open the catalog to page 2A multitude of functions in a compact body Easy standard testing Measurement current Upper limit Measurement time Test condition file number Remaining time Measurement value Measurement value : If hold is not enabled, unit reverts to READY condition after 1 second. Versatile functions (Pressing SHIFT + STOP keys allows the user to make settings for each 3) Output current frequency switching (0:50 Hz /1:60 Hz) © PASS/FAIL hold function setting Determines whether the condition is held after detecting PASS or FAIL. © Hold function setting (0: Hold disabled/1: Hold enabled) Holds the condition...
Open the catalog to page 3All HIOKI E.E. CORPORATION catalogs and technical brochures
-
MR8827 Memory HiCorder
16 Pages
-
PW6001 Power Analyzer
20 Pages
-
Clamp On Power Logger PW3365-20
12 Pages
-
TEMPERATURE LOGGER LR5011
8 Pages
-
MEMORY HiCORDER MR8740, MR8741
12 Pages
-
General Catalog (2014)
108 Pages
-
HIOKI PW3336/PW3337 Power Meter
12 Pages
-
General Catalog (2013)
80 Pages
-
RM3544/RM3548 RESISTANCE METER
12 Pages
-
LR8431-20 MEMORY HiLOGGER
8 Pages
-
HIOKI 3423 Lux HiTESTER
2 Pages
-
HIOKI 8826 MEMORY HiCORDER
12 Pages
-
HIOKI 3258 Safety HiTESTER
4 Pages
-
HIOKI 3120 Voltage Detector
2 Pages
-
HIOKI MR8875 MEMORY HiCORDER
14 Pages
-
HIOKI 3390 Power Analyzer
16 Pages
-
HIOKI 3554 BATTERY HiTESTER
4 Pages
-
HIOKI 3151 EARTH HiTESTER
2 Pages
-
HIOKI 3535 LCR HiTESTER
8 Pages