Catalog excerpts
Electrical Measuring Instruments General Catalog Recorders Power Electronic Field Recorders / Data Loggers / Remote Measurement System / Component Measuring Instruments / Signal Sources / Safety Standards Measuring Instruments / Power Measuring Instruments / Clamp on Sensors / Measurement in Telecommunications / Environmental Measuring Instruments / Digital Multi Meters / Insulation and Earth Testers / Clamp Meters / Meter Relays / Automatic Testing Equipment
Open the catalog to page 1About the Catalog Searching for product pages and notes ... Products in this catalog are grouped according to functions so you can easily find the right instrument for your application by referring to the list of product groups in the table of contents on the first page, and moving directly to the indicated section. Dimensions and mass: Exterior dimensions exclude protrusions, and are given in order of width(W), height(H), and depth(D), in mm units. Indicated weight represents an approximation of the mass of the main unit only, not including case, accessories, etc. HIOKI is certified under...
Open the catalog to page 2New Products MEMORY HiCORDER Fully Integrate into High-Speed, Multi-channel Measurement Systems DVM UNIT MR8990 Digital Voltage Meter The MR8740 uses a two-block internal architecture, essentially giving it the capabilities of two MEMORY HiCORDERs. Measure minute changes in voltage at a high level of precision. Simultaneous measurement of all channels--rather than scanner-type measurement--dramatically reduces cycle times. High-speed isolated measurement 20 MS/s isolated sampling Number of input units Simultaneous 20M sampling within the same block Systems Integration When using analog...
Open the catalog to page 3New Products CLAMP ON POWER LOGGER Identify Your Power Condition To Reveal Energy Saving Ideas Now with QUICK SET Convenience The Best Choice Available Reliable measurements start with proper wiring. The QUICK SET function guides you in making the right connections. SPECIFICATIONS Measurement line type 50/60 Hz, Single-phase 2-wire (1P2W: 1 circuit/2 circuits/3 circuits) Single-phase 3-wire (1P3W, 1P3W1U) Three-phase 3-wire (3P3W2M, 3P3W3M) Three-phase 4-wire (3P4W) Leak current/load current only: 1 to 3 channels Voltage, current, frequency, active power (for consumption and Measurement...
Open the catalog to page 4New Products DIGITAL MULTIMETER Speedy Performance of Professional Testing Two models provide high accuracy and fast response Current measurement available with optional clamp. Basic Accuracy ■ 60,000 count, 5-digit display of high resolution measurements ■ Remove harmonics with low pass filter (to measure the fundamental wave component of inverters) ■ Measure current with clamp sensors (DT4281) ■ PC data management via USB (option) ■ Wide operating temperature range of -15℃ to 55℃ ■ Built-in terminal shutter mechanism prevents accidents SPECIFICATIONS DT4281 DT4282 60.000 mV to 1000.0 V,...
Open the catalog to page 5New Products RESISTANCE METER A New Standard in Resistance Testing Simple ohmmeters High-precision portable ohmmeter suits both manual operation and integration with automatic lines n High-precision specs in a compact package Measure from 0.000 mΩ (@ 300 mA) to 3.5 MΩ n Production floor quality pass-fail judgments with LED COMPARATOR ATTACHMENT L2105 (option) and crystal clear audio signals n Integrates into various automatic lines, with NPN/PNPcompatible external I/O support (Model RM3544-01) Applications Windings (motors, solenoids, choke coils, transformers) Power contacts (contacts,...
Open the catalog to page 6Contents New products. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . P.New1 to New4 About the Catalog. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . P.1 Model Index. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . P.3 Recorders, Memory Recorders Power Measuring Instruments Electronic Measuring Instruments P.25 to 37 Safety Standards Measuring Instruments P.38 to 40 Environmental Measuring Instruments P.41 to 45 Clamp Sensors Clamp Testers Field Measuring...
Open the catalog to page 7Model Index 1000 or later ...Peripherals 5000 or later ...Leak current /LED optical meter /Signal sources 2000 or later ...Meter relays
Open the catalog to page 8Recorders, Memory Recorders Recorder, Memory Recorder Index For simultaneous recording of multiple signals Recorders, Memory Recorders 20MS/sec, Fully Integrate into High-Speed, Multi-channel Measurement Systems MR8740: Block I ; Analog 32ch, Logic 8ch Block II ;: Analog 22ch, Logic 8ch MR8741: Analog 16ch, Logic 16ch For simultaneous recording of multiple signals 1 MS/sec. (32 ch) 4 MW (1 ch) memoryexpandable up to 4 times 12-bits A/D resolution . . . . . . . . . . . . . . . p.10 15 ch to 600 ch isolated input Minimum 10 ms interval LAN/USB PC based data acquisition . . . . . . . . . . . ....
Open the catalog to page 9MEMORY HiCORDER Oscilloscope and Data Logger - Record Waveforms in Any Situation A faster CPU greatly enhances instrument operability and response. Multi-channel logging on up to 64 or 128 channels (Use with the 8958) 20 MS/s high-speed sampling (Use with the 8956) Various interfaces built-in: LAN/USB/PC-card slot Supports the new high-voltage input module for measuring high voltage directly. Recorders, Memory Recorders The MEMORY HiCORDER 8860-50 and 8861-50 cannot operate alone. You must install one or more optional input modules in the unit. Note: Memory boards are not built-in as a...
Open the catalog to page 10INPUT Units Dimensions and mass: approx. 170 (6.69in) W × 20 (0.79in) H × 148.5 (5.85in) D mm, approx. 290 g (10.2 oz) Accessories: None Dimensions and mass: approx. Dimensions and mass: approx. 170 (6.69in) W × 20 (0.79in) H × 148.5 (5.85in) D mm, approx. 310 g (10.9 oz) Accessories: None HIGH-RESOLUTION UNIT 8957 Measurement functions Number of channels: 2, for voltage measurement Isolated BNC connector (input impedance 1 MΩ, input capacitance 40 pF), Max. rated voltage to earth: 300 V AC, DC (with input isolated Input connectors from the unit, the maximum voltage that can be applied...
Open the catalog to page 11All HIOKI E.E. CORPORATION catalogs and technical brochures
-
MR8827 Memory HiCorder
16 Pages
-
PW6001 Power Analyzer
20 Pages
-
Clamp On Power Logger PW3365-20
12 Pages
-
TEMPERATURE LOGGER LR5011
8 Pages
-
MEMORY HiCORDER MR8740, MR8741
12 Pages
-
General Catalog (2014)
108 Pages
-
HIOKI PW3336/PW3337 Power Meter
12 Pages
-
RM3544/RM3548 RESISTANCE METER
12 Pages
-
LR8431-20 MEMORY HiLOGGER
8 Pages
-
HIOKI 3423 Lux HiTESTER
2 Pages
-
HIOKI 8826 MEMORY HiCORDER
12 Pages
-
HIOKI 3258 Safety HiTESTER
4 Pages
-
HIOKI 3120 Voltage Detector
2 Pages
-
HIOKI MR8875 MEMORY HiCORDER
14 Pages
-
HIOKI 3390 Power Analyzer
16 Pages
-
HIOKI 3554 BATTERY HiTESTER
4 Pages
-
HIOKI 3151 EARTH HiTESTER
2 Pages
-
HIOKI 3535 LCR HiTESTER
8 Pages