Company Overview
Hillesheim GmbH specializes in flexible electrical heating technology, providing solutions for transporting fluid or gaseous media without temperature loss. With over 35 years of experience, they offer products like heating hoses, tapes, mats, and plates, capable of handling temperatures up to 1000°C.
Document Structure
The document is organized into sections covering general information, industrial and analytical heating hoses, flexible trace heaters, surface heating elements, heating systems, and control technology.
General Technical Data
Flexible heating hoses are recommended for transporting media without heat loss, maintaining a constant temperature to ensure consistent quality and avoid condensation. Key components include connection fittings, temperature sensors, and thermal insulation.
Applications
Hillesheim heating hoses are used in industries such as foam installations, transportation technology, flue gas analysis, plastics processing, food processing, adhesives engineering, medical technology, petrochemicals, and surface technology.
Electrical Heating Systems
Designed for optimal heat distribution, these systems are equipped with temperature sensors and must be monitored with suitable controllers. Special hoses are available for explosion-hazard areas.
Installation Recommendations
Proper installation is crucial to avoid stress and damage. Hoses should be free of tensile stress, and bending radii should be respected. Heat build-up should be avoided by ensuring proper ventilation and avoiding contact between hoses.
Protection Types
Defined by EN 60529, protection types detail protection against solid objects and water ingress, ranging from not protected to dust-tight and water-resistant.
Industrial Heating Hoses
Type codes specify heating hose, sensor, outer protection, fitting, and pressure hoses. Rated power and nominal length vary by type and diameter, with a test voltage of 2000 Volt.
Industrial Pressure Hoses
Various types with different materials and specifications for operating pressure, bend radius, and temperature stability. Temperature correction factors apply for different temperatures.
Industrial Pressure Hose Fittings
Different fittings available, affecting hose throughput and stability.
Protective Braiding and End Caps
Various materials for protective braiding, each with specific temperature stability. Hard caps provide tear and twist protection, while soft caps offer temperature stability and kink protection.
Applications and Specifications
Heating hoses are used for transporting substances like oil, grease, adhesives, and hot-melt. Operating temperatures and rated voltages vary by series and application.
Temperature Control
Emphasizes the importance of temperature control using integrated systems like the HTI controller to ensure optimal heat transfer.
Key Features
Hoses feature thermal insulation, outer protective braiding, and temperature sensors to ensure efficient operation.
Recommendations
Recommends using appropriate temperature control systems and ensuring proper installation and maintenance to maximize efficiency and lifespan.
Flexible Heating Jackets
HFM Series jackets are constructed from heating tape and insulation, suitable for trace heating of pipes. Operating temperatures range from frost protection to 600°C.
Clip Attachment Tracer Heater
Designed for thin pipes and hoses, allowing heating without dismantling pre-installed systems.
Analytical Heating Hoses
Used for maintaining temperatures in sample gas lines, preventing condensation and temperature drops.
Key Features and Options
Customization options include different materials for inner cores, outer protection, and end connections.
Heating Solutions
Includes heating sleeves, barrel heating systems, surface heating elements, and explosion-proof electrical heaters.
Explosion-Proof Heaters
Classified for use in explosive environments, certified to ATEX standards.
Technical Specifications
Details materials, dimensions, insulation thickness, and connection types for each product.
Safety and Compliance
Emphasizes adherence to safety standards and regulations, particularly in explosive environments.
Temperature Controllers and Regulators
Designed for precise temperature control in industrial applications, with a focus on ease of use and reliability.
HT 54 Series SMD Miniature Controller
Designed for PT100 sensors, integrating directly into heating systems.
SSR Relays
HER series SSR electronic load relay designed for high switching frequency without wear on contacts.
Temperature Sensors
Available in various configurations, with maximum temperatures ranging from 450°C to 1000°C.
See more

Catalog excerpts

Hillesheim general catalogue-1

Flexible electrical heating technology Tracer Heater Systems Heating Hose Systems Manufacturing Engineering Hillesheim GmbH · Am Haltepunkt 12 · Industriegebiet 4 · D-68753 Waghäusel Tel.: 07254 / 9256-0 · Fax: 07254 / 9256-20 · e-mail: [email protected] www.hillesheim-gmbh.de · www.heizschlauc

 Open the catalog to page 1
Hillesheim general catalogue-2

Your contact persons Hillesheim GmbH Am Haltepunkt 12 D-68753 Waghäusel [email protected] www.hillesheim-gmbh.de www.heizschlauch.de Tel.: 0049 (0) 7254 / 9256-0 Fax: 0049 (0) 7254 / 9256-20 Sales department Mr. Baumgart Mr. Trautwein Mr. Wolff Technical specifications in this catalogue may vary according to the state of development. Revision status: May 2014

 Open the catalog to page 2
Hillesheim general catalogue-3

Company portrait Providing heat, maintaining heat A warm welcome to Hillesheim GmbH Do you have the problem of transporting fluid or gaseous media without temperature losses from A to B in hoses and pipes? Or should they be heated from temperature "x" to temperature "y"? If you are looking for a technical and economical solution for such tasks, you should consult us. Because we deliver you expertise from over 35 years of practical experience. Thousands of electrical trace heating systems (heating hoses, heating tapes, heating mats, heating plates) are still performing their tasks for our customers...

 Open the catalog to page 3
Hillesheim general catalogue-4

we have the right electri-

 Open the catalog to page 4
Hillesheim general catalogue-5

1. General information and data . . . . . . 1 -10 2. Industrial heating hoses . . . . . . . . . 11 – 34 3. Analytical heating hoses . . . . . . . . . 35 – 48 4. Flexible trace heaters . . . . . . . . . . . 49 – 68 5. Surface heating elements . . . . . . . . 69 – 82

 Open the catalog to page 5
Hillesheim general catalogue-7

General technical data General technical information and data for our heating hose systems

 Open the catalog to page 7
Hillesheim general catalogue-8

Description and structure of a Hillesheim heating hose Whenever hot and warm media have to be transported from a device to another part of the device or plant without heat loss and the lines are not intended be rigidly routed, flexible heating hoses are recommended as conveying elements. In most applications, it is necessary to maintain the product temperature at a predefined value. By using Hillesheim heating hoses, a constant temperature of the material conveyed is ensured through to the application site, without the material temperature being influenced by ambient temperatures and heat losses...

 Open the catalog to page 8
Hillesheim general catalogue-9

Application examples New: Also for use in explosion hazard areas Foam installations Packaging foam, PUR foam 2-component equipment, 4-component equipment Transportation technology Lorry, ship transfer and delivery hoses silo and levelling hoses Flue gas analysis technology gy Exhaust gas measurement and analysis lines d an Sampling probes Flue gases Emission measurements s Plastics processing Injection moulding Extrusion, co-extruders ers Foams Mould-making Plant and apparatus engineering ratus engineering a s n n er g Filling and sealing equipment ng equipment g q p e t Food processing ng Tool...

 Open the catalog to page 9
Hillesheim general catalogue-11

Electrical heating systems info Plug connections: The plug connections on Hillesheim standard heating hoses are equipped with a plug compatible with one of our controllers. The HT43 temperature controller is provided with a round socket as standard. Please note that for unsupervised operation. there must be an additional safety device (limiter, temperature fuse...) fitted in the heating system. We can also supply our hoses without plugs for connecting the cable to terminals or for fitting to customer plugs. We use plug connectors from many well-known manufacturers. We can also fit their plugs...

 Open the catalog to page 11
Hillesheim general catalogue-12

Installation recommendations Along the lines of DIN 20066: 2002-10 Wrong Pulling on the ends of rolled hoses causes torsional stress and can subject them to bending radii smaller than is permissible. Hoses are not to be twisted. Remedy: unroll the ring of hose rather than pulling it off. Hose lines should be installed in such a manner that they are free of tensile stress in all operational states; similarly, jamming stress (i.e. axial compression along the length) on short lengths of hose is to be avoided. Axial compression due to incorrect installation or space-reducing motion degrades the hose's...

 Open the catalog to page 12
Hillesheim general catalogue-13

Installation recommendations Avoid twisting the hose when connecting it to moving parts, particularly when motion and bending take place in the same plane. This can be achieved through proper installation or design measures (e.g. swivel joint). The danger of kinking is particularly high for handheld devices. Remedy: Depending on the operating position, install a elbow or kink protection (e.g. corrugated hose). For installation in an arc, a hose length should be selected such that the intended bend can be formed beyond a length of ≈ 1.5 d0 ; kink protection may also be necessary (e.g. hard cap)....

 Open the catalog to page 13
Hillesheim general catalogue-14

Installation recommendations Heat build-up will occur if heating hoses are routed through a closed channel or shaft. Remedy: hoses may not touch one another. Furthermore, sufficient ventilation is to be provided. If, for example, powder-like substances, adhesives or other thermally insulating materials accumulate on heating hoses, then overheating will occur at such points. Remedy: eliminate the cause with regular cleaning to remove such materials. Heat build-up is caused by incorrect wrapping of the heating hose with other materials. The heating hose will overheat at such points. If the sensor...

 Open the catalog to page 14
Hillesheim general catalogue-15

Protection type / protection class Protection types for electrical equipment according to EN 60529 Protection types against solid foreign objects, denoted by the first numeral First Short description Definition numeral Not protected – 0 Protected against solid foreign The object probe, a sphere of 50 mm diameter shall not fully 1 objects penetrate 50 mm diameter and larger Protected against solid foreign The object probe, a sphere of 12.5 mm diameter shall not 2 objects fully penetrate 12.5 mm diameter and greater Protected against solid foreign The object probe, a sphere of 2.5 mm diameter shall...

 Open the catalog to page 15

All Hillesheim GmbH catalogs and technical brochures

  1. catalogue

    124  Pages

Archived catalogs

*Prices are pre-tax. They exclude delivery charges and customs duties and do not include additional charges for installation or activation options. Prices are indicative only and may vary by country, with changes to the cost of raw materials and exchange rates.