Hiden Analytical specializes in designing quadrupole mass spectrometer systems, known for their high sensitivity, accuracy, and reproducibility. These systems are utilized in advanced applications such as catalysis and thermal analysis.
CATLAB - Automated Microreactor/MS System
The CATLAB system integrates a microreactor with a mass spectrometer for catalyst characterization and reaction studies, offering automated control over gas composition, temperature, and mass spectrometer parameters.
CATLAB-FB - Horizontal Furnace/MS System
This system combines a furnace and mass spectrometer for analyzing catalyst cores at high temperatures, featuring multi-stream gas flow control and options for pulse chemisorption and vapor feed systems.
BASELINE SYSTEMS for Gas Analysis
These systems, including the HPR-20 R&D, QGA, and EXQ, are designed for various levels of gas analysis, featuring fast data acquisition and integration with external process data.
HPR-20 TMS - Transient MS for Fast Event Gas Analysis
Configured for fast event analysis, this system offers rapid response times and is ideal for fast gas switching experiments.
HPR-20 EGA for Evolved Gas Analysis in TGA-MS
This system is designed for continuous analysis of evolved gases from thermogravimetric analyzers, featuring custom interfaces and EGAsoft software.
SpaciMS - Spatially Resolved Capillary Inlet MS
SpaciMS provides high spatial and temporal resolution for species determination and temperature profiling, suitable for applications like fuel cell studies.
TPD WORKSTATION
A complete system for UHV TPD/TDS studies, featuring a multiport UHV chamber and a high precision mass analyzer.
UHV TPD for Fast Event UHV Studies
Hiden’s 3F PIC Series Quadrupoles offer high precision and sensitivity for fast event studies.
HPR-40 DEMS for Dissolved Gas Analysis
This system analyzes dissolved species in electrochemistry, featuring fast response times and modular configuration.
APPLICATION SOFTWARE
QGA Professional Edition software provides real-time quantitative analysis of gases and vapors, supporting up to 32 species with concentration measurements from 0.1 ppm to 100%.
QGA Professional Features
The QGA Professional system is capable of quantitative gas analysis for up to 32 gases, with features like a spectral library and automatic triggering of analysis.
MASsoft Software
MASsoft is a multilevel software package for controlling mass spectrometer parameters and data manipulation, supporting data export to external analysis software.
Thermal Analysis Software
This includes application-specific software for data acquisition and control, such as EGAsoft and TPDsoft, supporting automatic exports to TGA manufacturers’ software.
CATLAB Software
CATLAB software is used with Hiden CATLAB systems for controlling MS data acquisition and other devices, managing gas composition changes and MS analysis.
Applications
The systems are applicable in various fields including TA-MS, catalysis, UHV TPD, off-gas analysis, surface analysis, plasma diagnostics, and vacuum analysis.
Contact Information
Hiden Analytical Ltd. is based in Warrington, England, with sales offices globally. Contact details are available on their website.
See more

Catalog excerpts

Mass Spectrometers for Catalysis and Thermal Analysis-1

CATALYSIS & THERMAL ANALYSIS Mass Spectrometers for Catalysis & Thermal Analysis Applications

 Open the catalog to page 1
Mass Spectrometers for Catalysis and Thermal Analysis-2

MASS SPECTROMETERS for Catalysis & Thermal Analysis Applications Hiden Analytical have been designing and developing the highest quality quadrupole mass spectrometer based gas analysis systems for over 35 years. We have built a reputation for delivering instruments with superior sensitivity, accuracy and reproducibility together with a first class global service and applications support network. From dedicated triple filter UHV TPD quadrupoles to fully integrated catalysis microreactor and mass spectrometer systems, Hiden have developed a range of analytical mass spectrometers that address the...

 Open the catalog to page 2
Mass Spectrometers for Catalysis and Thermal Analysis-3

Contents CATLAB - Automated Microreactor/MS System CATLAB-FB - Horizontal Furnace/MS System for Catalyst Core Quantification BASELINE SYSTEMS - for Gas Analysis TGA-MS Interface HPR-20 TMS - Transient MS for Fast Event Gas Analysis HPR-20 EGA - for Evolved Gas Analysis in TGA-MS SpaciMS - Spatially Resolved Capillary Inlet MS TPD WORKSTATION - A System for UHV Temperature Programmed Desorption (TPD/TDS) Studies UHV TPD - for Fast Event UHV Studies HPR-40 DEMS - for Dissolved Gas Analysis and Off-gas Analysis in Electrochemistry APPLICATION SOFTWARE - QGA Professional, MASsoft Professional, Thermal...

 Open the catalog to page 3
Mass Spectrometers for Catalysis and Thermal Analysis-4

Automated Microreactor/MS System The Hiden CATLAB is a bench-top microreactor and combined mass spectrometer system for rapid and reproducible catalyst characterisation and reaction studies. The microreactor and mass spectrometer are delivered as a complete system from a single manufacturer, unique to the industry, ensuring optimum analysis via seamless hardware and software integration. The modular design further allows both instruments to operate as stand-alone components so that they may be interfaced with existing laboratory equipment such as TGAs (TG-MS) or Gas Chromatographs. The Hiden...

 Open the catalog to page 4
Mass Spectrometers for Catalysis and Thermal Analysis-5

Horizontal Furnace/MS System for Catalyst Core Quantification The CATLAB-FB is a combined furnace and mass spectrometer system for the analysis of catalyst core specimens at temperatures up to 1000°C, with multi-stream gas/vapour flow control and mass spectral analysis of both feed and downstream gases. The furnace houses a horizontal quartz reactor tube with in-bed thermocouple for optimum thermal precision, a standard internal diameter of 26 mm and a uniform central hot-zone of 150 mm. The furnace is programmable from 50°C through to 1000°C at a fastest ramp rate of 20°C/ minute. The system...

 Open the catalog to page 5
Mass Spectrometers for Catalysis and Thermal Analysis-6

BASELINE SYSTEMS for Gas Analysis BASELINE SYSTEM FEATURES INCLUDE:  Sample pressure range 2 bar to 100 mbar  Continuous sampling with inlet flow rate configurable down to 1 ml/min  Low dead volume, heated inlet for fast response to vapours  Species molecular weight range to 200 amu  Fast data acquisition speeds > 500 readings/second in transient mode  Fast 300 ms sampling response EXQ - compact gas analyser for less demanding applications  Time/intensity trend monitoring of multiple species  APSI-MS soft ionisation mode for suppression of spectral fragmentation providing simplified analysis...

 Open the catalog to page 6
Mass Spectrometers for Catalysis and Thermal Analysis-7

Transient MS for Fast Event Gas Analysis The Hiden HPR-20 TMS Transient MS is configured for fast event analysis of gases and vapours at pressures near atmosphere. Ideal for fast gas switching experiments, the MS features the Hiden QIC quartz-lined 0.9 m sampling interface. The inlet, operating at 200°C, provides response times of less than 150 ms to changes in gas composition with a 5 decade response time in < 100 ms. The QIC inlet is coupled directly to Hiden’s Pulse Ion Counting (PIC) digital MS which is capable of measurement speeds of up to 500 data points/s over the entire 7 decade dynamic...

 Open the catalog to page 7
Mass Spectrometers for Catalysis and Thermal Analysis-8

for Evolved Gas Analysis in TGA-MS The Hiden HPR-20 EGA gas analysis system is configured for continuous analysis of evolved gases and vapours from thermogravimetric analysers (TGA). Interface systems are available for most TGA instruments. The TGA interface includes re-entrant furnace sampling, providing close coupling to the TGA furnace region for optimized evolved gas/vapour analysis. Custom designed interfaces are available for special requirements with alternative systems being offered for applications requiring direct sampling from advanced thermogravimetric analysers operating at higher...

 Open the catalog to page 8
Mass Spectrometers for Catalysis and Thermal Analysis-9

Spatially Resolved Capillary Inlet MS The Hiden Analytical spatially resolved capillary inlet MS (SpaciMS) is the first commercially available instrument of its kind. Recipient of a R&D 100 award, the SpaciMS inlet was originally conceived and developed by researchers at the Oak Ridge National Laboratory and Cummins, Inc. to study diesel catalysis1 and has been further developed for a whole range of applications. SpaciMS allows both radial and axial species determination and temperature profiles, with high spatial and temporal resolution and with negligible interference in flow or temperature....

 Open the catalog to page 9
Mass Spectrometers for Catalysis and Thermal Analysis-10

A System for UHV Temperature Programmed Desorption (TPD/TDS) Studies The Hiden TPD Workstation is a complete experimental system for analysis of thermal desorption products by UHV TPD/TDS. The TPD Workstation features a multiport UHV chamber with heated sample stage coupled to a high precision triple filter analyser with digital pulse ion counting detector for ultimate sensitivity and time resolution. The triple filter mass analyser is configured with a cooled shroud giving minimum outgassing with optimum sensitivity of the analyser to desorption products from the sample. A fast sample load lock...

 Open the catalog to page 10
Mass Spectrometers for Catalysis and Thermal Analysis-11

for Fast Event UHV Studies Hiden’s 3F PIC Series Quadrupoles are high precision triple filter analysers with digital detectors for ultimate sensitivity and time resolution in fast event studies such as UHV TPD. 3F Series analysers are available with UHV compatible mass filter shrouds and low profile ion source for close positioning to the desorption surface. Both analogue and digital inputs are provided for synchronous acquisition start and sample temperature data display alongside mass channel data. Application specific software and external device program protocols (RS485, Modbus) enable the...

 Open the catalog to page 11