Cluster Analysis Brochure

Cluster Analysis Brochure

Cluster Analysis Brochure

Product catalog summary
Introduction
Hiden Analytical specializes in manufacturing high-mass range quadrupole mass spectrometers and sampling inlets for advanced materials science research, focusing on nanoscale particles and clusters. These instruments are crucial for cluster deposition and spectroscopy applications.

Specifications and Features
The quadrupole mass filter is essential for ion transport and mass selection, offering sufficient mass resolution and a 100% duty cycle. Key features include a mass range up to 20,000 amu, frequencies from 0.4 to 5 MHz, switchable zones of operation, pole bias capability, ultra-stable voltage, and 100 Watts of true RF power. The high power RF generator allows for a mass range of 5,000 m/z even with a 9 mm triple filter quad, providing outstanding performance and resolving power.

Applications
Applications include molecular clusters, cluster deposition, ion clusters, nano structures, spectroscopy, and ion redirection. The systems are designed for UHV analysis of neutrals, radicals, and ions, supporting studies like electron stimulated desorption and thermal desorption.

Product Range
Hiden Analytical offers a range of products including transfer quadrupoles with 9 mm and 20 mm pole diameters, beam deflectors, and systems like the EPIC 5000 for gas-phase cluster studies. The EPIC and IDP systems feature high performance RGAs with pole bias mid-axis potential and negative ion capability.

Performance and Options
Performance metrics for quadrupole mass spectrometers include relative transmission, resolving power, and sensitivity across various models. The systems support a broad range of applications in gas analysis, surface analysis, plasma diagnostics, and vacuum analysis.

Contact Information
Hiden Analytical Ltd. is based in Warrington, England, with sales offices globally. For more information, visit their website or contact them directly.
See more

Catalog excerpts

Cluster Analysis Brochure-1

Quadrupoles and Components for Cluster Analysis, Nanoscale Particles Hiden Analytical manufacturers high-mass range quadrupole mass spectrometers and sampling inlets for advanced materials science research, including the analysis of nanoscale particles and clusters.

 Open the catalog to page 1
Cluster Analysis Brochure-2

Detailed product information / introduction Clusters and nanoparticles Quadrupoles and Components for Cluster Analysis, Nanoscale Particles Clusters and nanoparticles can be generated from a variety of sources, such as electrospray ionisation, laser evaporation and magnetron sputtering and at pressures from sub-millibar to atmospheric. The quadrupole mass filter plays a key role in the transport and mass selection of these ions, as it possesses sufficient mass resolution and a 100% duty cycle. The production of size-selected clusters is used for two main applications, cluster deposition and spectroscopy....

 Open the catalog to page 2
Cluster Analysis Brochure-3

Cluster Analysis Components Hiden Analytical develops and supplies the instruments for a new era of cluster analysis and implementation of nanoscale particles. 9 mm and 20 mm pole diameter quadrupoles mounted on DN-150-CF double sided Conflat flange. With adjustable tilt, part number 582000

 Open the catalog to page 3
Cluster Analysis Brochure-4

Systems for UHV analysis of neutrals, radicals and ions including electron impact ioniser, SEM detector, and ion optics The EPIC 1000 series boasts a mass range of up to 20,000 atomic mass units (AMU) to assist with gas-phase cluster studies, while a range of distinct sampling inlets is available upon request. The Hiden EPIC and IDP have all the features of high performance RGAs – but with the addition of pole bias mid-axis potential and negative ion capability making them outstanding research grade mass spectrometers. The Hiden IDP (Ion Desorption Probe) is for the direct analysis of low energy...

 Open the catalog to page 4
Cluster Analysis Brochure-5

System Configuration & Options TRANSFER QUADRUPOLE MASS SPECTROMETERS PERFORMANCE FOR HIGHER MASS RANGES Features with Triple Filter Resolving Power (FWHM) Relative Transmission Frequency Relative MHz Transmission Mounting flange for the transfer quadrupoles is a double sided DN-150-CF with radial feedthroughs. *Figures based on Ion Modelling projection. QUADRUPOLE MASS SPECTROMETERS PERFORMANCE FOR HIGHER MASS RANGES Features with Triple Filter * Figures based on Ion Modelling projection. Resolving Power (FWHM) Relative Transmission Frequency Relative MHz Transmi

 Open the catalog to page 5
Cluster Analysis Brochure-6

Hiden’s quadrupole mass spectrometer systems address a broad application range in: GAS ANALYSIS dynamic measurement of reaction gas streams catalysis and thermal analysis molecular beam studies dissolved species probes fermentation, environmental and ecological studies SURFACE ANALYSIS UHV TPD SIMS end point detection in ion beam etch elemental imaging – 3D mapping PLASMA DIAGNOSTICS plasma source characterisation etch and deposition process reaction kinetic studies analysis of neutral and radical species VACUUM ANALYSIS partial pressure measurement and control of process gases reactive sputter...

 Open the catalog to page 6
*Prices are pre-tax. They exclude delivery charges and customs duties and do not include additional charges for installation or activation options. Prices are indicative only and may vary by country, with changes to the cost of raw materials and exchange rates.