DRT-15CE Portable Turbidimeter

DRT-15CE Portable Turbidimeter

Product catalog summary
Specifications
The DRT-15CE Portable Turbidimeter is designed for both field and laboratory use, offering a range of 0 to 1000 NTU with varying accuracy levels depending on the range. It features a resolution of 0.1% of the selected range and provides immediate response time. The device operates on a 6V gel-cell rechargeable battery, allowing for 20 hours of continuous use, and requires 8 hours to fully recharge. It functions within an operating temperature of 32° - 122°F (0° - 50°C) and complies with USEPA standards.
Standard Features
The turbidimeter comes with a rugged portable carrying case, is completely self-contained, and offers three user-selectable ranges for accuracy across different applications. It includes a 20-hour rechargeable battery and an automobile adapter for charging and operation from a car cigarette lighter. The ProCal Calibration Standards allow for quick and easy calibration without mixing Formazin.
Optional Features
The DRT-15CE is designed for rugged portability and laboratory accuracy, making it essential for monitoring turbidity on the go. It includes an integral carrying case and offers a resolution of 0.01 NTU with an extended range to 1,000 NTU.
Accessories
Available accessories include a 12V automobile adapter (Cat. No. 19045), ProCal Calibration Kit (Cat. No. 39071), and cuvettes in packs of 3 or 10 (Cat. Nos. 50051 and 50052). The DRT-15CE is available in 120 VAC (Cat. No. 19057) and 240 VAC (Cat. No. 19058) versions.
Ordering Information
For more information, visit www.hfscientific.com or contact via email at [email protected]. Phone support is available at (239)-337-2116 or toll-free at 888-203-7248.
See more

Catalog excerpts

DRT-15CE Portable Turbidimeter-1

Water Quality Measurement Solutions A Watts Water Technologies Company Designed to provide the rugged portability needed in the field with the accuracy demanded in the laboratory, the EPA accepted DRT-15CE has become a "must have" for anyone monitoring turbidity on the go. The integral carrying case holds everything needed for field operation. With resolution of 0.01 NTU and an extended range to 1,000 NTU, the DRT-15CE is a perfect fit for both field and laboratory use. Standard Features • Rugged Portable Carrying Case Ensures durability and convenience no matter where your laboratory • Completely Self-Contained Provides easy access to everything you need to take a measurement. • Three User Selectable Ranges Provides accuracy in a wide variety of applications from 0 to 1000 NTU. • 20 Hour Rechargeable Battery Always be ready to go with up to 20 hours of continuous operation when fully charged. Optional Features • Automobile Adapter Charge and operate the DRT-15CE from the cigarette lighter in your • fmCd Calibration Standards Quick and easy calibration across all ranges without the need to mix • Formazin Stock Solution Kit Contains everything you need to calibrate the DRT-15CE with Formazin, the primary calibration standard. Ordering Information * The DRT-15CE exceeds performance criteria specified by US EPA 12V Automobile Adapter to operate & charge the DRT-15CE from a cigarette lighter plug. * The DRT-15CE exceeds performance criteria specified by US EPA Specifications subject to change without notice. 3170 Metro Parkway, Ft. Myers FL 33916 e-mail: [email protected] ph: (239)-337-2116 • fax: (239) 332-7643 • toll free: 888-203-7248 www.hfscientific.com