Safe plate

Safe plate

Safe plate

Product catalog summary
Overview: SafePLATE brazed plate heat exchangers are designed for high-efficiency heat transfer applications where detecting internal leakage between media is crucial. They feature a special arrangement of double walls and interspace in sidewalls to prevent fluid mixing and allow visual leakage detection.
Applications: These heat exchangers are suitable for tap water heating systems, central heating systems, HVAC, technological, cooling, and industrial installations, especially where media need protection from mixing.
Materials: Constructed from stainless steel with copper brazing.
Exemplary Media: Water, glycol, and other media as consulted with the producer.
Technical Parameters:
  • Max. temperature: 230°C / 446°F
  • Min. temperature: -195°C / -319°F
  • Max. pressure: LA SP, LB SP: 3 MPa / 435 PSI; LC SP: 2 MPa / 290 PSI
Insulation: Two-part insulation made of polyurethane foam covered with aluminum, fastened with latch clamps. Max. working temperature: 135°C / 275°F, thickness: 30 mm/1.19 in, thermal conductivity: 0.024 W/mK.
Construction: These are counter-current flow devices with heat exchange areas created by stainless steel corrugated plates brazed together. Media flow through channels formed by every other heating plate, with connections placed in the cover plate.
Compliance: Manufactured in compliance with PED, ASME, CHINA ML, EAC, UL standards.
Flow Channels Arrangement: Various models (LA14SP, LB31SP, LB60SP, LC110SP) with different connection sizes and flow channel arrangements.
See more

Catalog excerpts

Safe plate-1

5a Fe PLATE™ brazed plate heat exchangers with double-wall system »> eFFective heat transFer »>

 Open the catalog to page 1
Safe plate-2

TECHNICAL PARAMETERS f ^ SafePLATE brazed plate heat exchangers are designed for applications requiring high efficiency of heat transfer where it is crucial to detect internal leakage between the media. In case of failure, either corrosion or pressure induced, special arrangement of double walls and interspace in sidewalls prevents fluids from mixing and allow visual detection of a leakage. V) - tap water heating systems - central heating systems - applications where media need to be specially protected from mixing - HVAC, technological, cooling and industry installations ■ CONSTRUCTION SafePLATE...

 Open the catalog to page 2

All HEXONIC CZ s.r.o. catalogs and technical brochures

  1. CIP

    13  Pages

  2. JAG SHIELD

    7  Pages

  3. JAD

    13  Pages

  4. DNA

    5  Pages

  5. LA21AS

    5  Pages

*Prices are pre-tax. They exclude delivery charges and customs duties and do not include additional charges for installation or activation options. Prices are indicative only and may vary by country, with changes to the cost of raw materials and exchange rates.