JAD - 1

JAD Shell & Coil Heat Exchangers

Open the catalog to page 1
JAD - 2

JAD heat exchangers JAD heat exchangers due to their design and performance are ideally suited to the most demanding applications. Large heat exchange area within compact dimensions and high performance comparing to standard solutions are widely appreciated on the market. Made entirely of stainless steel, they constitute a durable construction. Design flexibility make them suitable for most heat transfer systems. Due to their properties, JAD heat exchangers are mostly used in heating installations and substations, while JAD X in installations with increased requirements.

Open the catalog to page 2
JAD - 3

Why to choose JAD heat exchangers? SPACE SAVING Compact dimensions and vertical installation reduces space required for installation. X-shaped connections and corrugated tubes make the exchangers more resistant to fauling. HIGH EFFICIENCY WIDE APPLICATION Higher heat transfer coefficient - corrugated tubes promote flow turbulence and thus intensify heat exchange. Wide range of temperature and pressure, flow velocity and media. EASY SELECTION Manufactured in accordance with ASME, PED. With user-friendly CAIRO Selection Software.

Open the catalog to page 3
JAD - 4

JAD construction Coil ended on both sides with tube sheets placed in heads. Tubes side connections Dished head Heat exchange area consists of layers of helicoidal coaxial counter coiled tubes of diameter Ø 8 mm or 10 mm (0.31 in or 0.39 in). Connections to be welded WD external thread GZ Victaulic VC shell side connections Non-dismountable welded construction. High-alloy austenitic stainless steel. Vertical mountin

Open the catalog to page 4
JAD - 5

Shell and coil heat exchangers TECHNICAL DRAWING Standard location of connections (in counterflow): K1/ K4 – inlet/outlet hot side K3/ K2 – inlet/outlet cold side WORKING PARAMETERS

Open the catalog to page 5
JAD - 6

TECHNICAL PARAMETERS All dimensions and technical data are approximate only and may be changed without further notice. Heat exchange area Tube diameter Tube side volume Shell side volume we i gh t fo r F F vers ion with fl a nges Connection size SS - stai n l e ss steel , CS – ca rbon steel , WD – connecti on to b e we lde d, GZ - exte r nal threa

Open the catalog to page 6
JAD - 7

Shell and coil heat exchangers TECHNICAL DRAWING Standard location of connections (in counterflow): K1/ K4 – inlet/outlet hot side K3/ K2 – inlet/outlet cold side WORKING PARAMETERS

Open the catalog to page 7
JAD - 8

TECHNICAL PARAMETERS All dimensions and technical data are approximate only and may be changed without further notice. Heat exchange area Tube side volume l Shell side volume l * we i gh t fo r F F vers ion with fl a nges Type of connections Flange CS SS - stai n l e s s steel , CS – ca rbon steel , WD – connecti o n to b e we lde d, GZ - exte r nal thread, VC -Vi ctauli

Open the catalog to page 8
JAD - 9

Shell and coil heat exchangers Technical drawing Standard location of connections (in counterflow): K1/ K4 – inlet/outlet hot side K3/ K2 – inlet/outlet cold side WORKING PARAMETERS

Open the catalog to page 9
JAD - 10

TECHNICAL PARAMETERS All dimensions and technical data are approximate only and may be changed without further notice. Heat exchange area Tube diameter Tube side volume Shell side volume * we i ght fo r F F vers ion with fl a nges Connection size SS - stai n l e ss steel , CS – ca rbon steel , WD – connecti on to b e we lde d, GZ - exte r nal th

Open the catalog to page 10
JAD - 11

Heat exchange in industrial processes District heating substations Ventilation systems Air-conditioning systems Heating systems Chemical and food industry

Open the catalog to page 11
JAD - 12

Stainless steel Flanges: stainless steel (SS)      or carbon steel (CS) Exemplary media • Propylene glycol solutions

Open the catalog to page 12
JAD - 13

Insulation AMWI Mineral wool covered with aluminium • • Polyurethane foam • • Thermal conductivity: 0,024 W/mK / 0.014 Btu/ft. hour °F

Open the catalog to page 13
JAD - 14

ACCESSORIES Mounting brackets • Made of stainless steel EXEMPLAR DESIGNATION JAD XK 2.11.08.68 FF.PRO.SS heat exchanger type K - coil made of corrugated tubes, without letter K - coil made of smooth tubes exchanger size tube diameter [mm]; lack of designation means tubes diameter is 8 mm shell length working parameters material group (PRO or STA) PRO - 316L /1.4404; STA - shell 304L /1.4307, tubes 321 /1.4541 material of flanges (SS-stainless steel, CS- carbon steel), WD - to be welded, VC - Victaulic, GZ - external thread

Open the catalog to page 14

All HEXONIC CZ s.r.o. catalogs and technical brochures

  1. HAD

    7 Pages

  2. DNA

    5 Pages

  3. JAD

    13 Pages

  4. BPHE

    17 Pages

  5. JAG SHIELD

    7 Pages

Archived catalogs

  1. Oil Coolers

    11 Pages

  2. Pool

    15 Pages

  3. P-line

    11 Pages

  4. HAD

    7 Pages

  5. BPHE

    13 Pages

  6. Dry cooler

    11 Pages

  7. ST

    3 Pages

  8. L-line

    3 Pages

  9. DNA ECO

    1 Pages

  10. R-line

    3 Pages

  11. Luna

    3 Pages

  12. Safe plate

    3 Pages

  13. Pool

    15 Pages

  14. P-line

    3 Pages

  15. PHE

    3 Pages

  16. L-line

    3 Pages

  17. JAD

    3 Pages

  18. Industrial

    7 Pages

  19. HAD

    3 Pages

  20. DNA

    5 Pages

  21. Custom

    3 Pages

  22. P-line

    3 Pages