1. Catalogs
  2. HEXONIC CZ s.r.o.
  3. HEAT EXCHANGERS POOL

HEAT EXCHANGERS POOL

HEAT EXCHANGERS POOL
1 / 15 PagesView full catalog

HEAT EXCHANGERS POOL

Product catalog summary
Overview: The document provides detailed information on Hexonic's pool heat exchangers, highlighting their design, compatibility, and technical specifications. These exchangers are designed to enhance heat transfer efficiency and are suitable for various pool types, including saltwater pools.
Design and Materials: Hexonic pool heat exchangers feature a special design with straight corrugated tubes that promote turbulent flow, enhancing heat exchange and reducing fouling. They are constructed from durable materials like titanium and stainless steel, making them resistant to corrosive environments.
Key Features:
  • Compatible with all types of heating and pool installations.
  • High performance with low pressure loss, eliminating the need for a bypass.
  • Easy installation and outstanding reliability.
  • User-friendly selection software for easy product selection.
Types of Heat Exchangers:
  • B Type: Shell and tube exchangers suitable for high-flow systems, offering high thermal efficiency and durability.
  • REV Type: Features a 3-pass tube bundle for exceptional heat exchange results, ideal for swimming pool installations.
  • TI Type: Titanium exchangers designed for saltwater pools, resistant to aggressive substances.
  • JAG Plate Heat Exchangers: Innovative design with jagged patterns for increased heat exchange area and efficiency.
Technical Specifications: The document includes detailed technical data for various models, such as dimensions, heat exchange area, tube diameter, weight, and capacity. It also provides working parameters like maximum temperature and pressure.
Applications: Hexonic heat exchangers are suitable for public and private pools, Olympic-size pools, hot tubs, SPA pools, and water parks. They can be used with various heat sources, including condensing boilers, geothermal water, heat pumps, solar systems, and district heating.
Conclusion: Hexonic's pool heat exchangers offer a reliable and efficient solution for pool heating needs, with advanced design features and compatibility with a wide range of pool and heating systems.
See more

Catalog excerpts

HEAT EXCHANGERS POOL-1

POOL HEAT EXCHA N G ER S

 Open the catalog to page 1
HEAT EXCHANGERS POOL-2

POOL H E AT E XC H A N G E R S Special design of our pool heat exchangers boosts heat transfer and delivers better utilization of heat source. Equipped with straight tubes all of the models ensure low pressure loss thus saving energy. Corrugated straight tubes promote turbulent flow which further intensifies heat exchange and helps reduce fouling. Cutting-edge technology and durable materials such as titanium and stainless steel, make our heat exchangers resistant to corrosive environments. They can be used with all types of pool water – either treated or salt. OUTSTANDING RELIABILITY COMPATIBLE...

 Open the catalog to page 2
HEAT EXCHANGERS POOL-3

HEAT EXCHANGER TYPE Pool B Public pool Private pool Olympic-size pool Kids’ pool Salt water pool Water park HEAT EXCHANGER TYPE Heat source type B Condensing boiler Coal boiler Geothermal water Heat pump Solar system District heating D I A G R A M O F S A LT WAT E R P O O L WITH A HEXONIC POOL HEAT EXCHANGER possibility best choice

 Open the catalog to page 3
HEAT EXCHANGERS POOL-4

B pool heat exchangers are characterized by high thermal eff iciency. They are HIGH VOLUME FLOW the perfect solution in high-flow systems, in particular pool systems of different B type exchangers are shell and tube exchangers equipped with straight corrugated tubes. They can be used in systems with high medium flow in comparison to transferred thermal power. It is a proven solution for pool and solar systems or small oil preheating systems. COMPACT SIZE The use of corrugated tubes intensif ies heat exchange and increases self-cleaning possibilities. Compact, welded B type exchangers are highly...

 Open the catalog to page 4
HEAT EXCHANGERS POOL-5

Connection size Type K1, K4 STANDARD LOCATION OF CONNECTIONS K 1 ⁄ K 4   ―  inlet / outlet heat source – internal thread K 3 ⁄ K 2   ―  inlet / outlet pool water – internal thread Dimensions Heat exchange area Tube diameter Tube side capacity Shell side capacity

 Open the catalog to page 5
HEAT EXCHANGERS POOL-6

Heat source temperature inlet Pool water temperature inlet Pool water Flow Heat source Pool water Pressure drop Heat source All dimensions and technical data are approximate only and may be changed without further notice.

 Open the catalog to page 6
HEAT EXCHANGERS POOL-7

REV pool heat exchangers achieve very high heat exchange coeff icient thanks to the 3-pass tube bundle. UNIQUE 3-PASS TUBE BUNDLE ENABLES BETTER UTILIZATION OF THE HEAT REV heat exchangers are intended for use mainly in swimming pool installations. The main priority in their design was to improve heat exchange conditions. EXCEPTIONAL HEAT This was achieved by using the 3-pass design of the tube bundle, which results in better utilization of source thermal power. Additionally, thanks to the short path of pool water (heated medium) through the exchanger, the flow speed remains high. LITTLE PRESSURE...

 Open the catalog to page 7
HEAT EXCHANGERS POOL-8

STANDARD LOCATION OF CONNECTIONS K 1 ⁄ K 4   ―  inlet / outlet heat source external thread G11/2" K 3 ⁄ K 2   ―  nlet / outlet pool water i WORKING PARAMETERS Pool water temperature inlet Heat source temperature inlet Pool water Flow Heat source Heat exchange area Tube diameter Tube side capacity Shell side capacity Pressure drop Heat source All dimensions and technical data are approximate only a

 Open the catalog to page 8
HEAT EXCHANGERS POOL-9

TI titanium pool exchangers are intended for use in pool systems with salt water. CORRUGATED TUBES INTENSIFY HEAT EXCHANGE AND TI type exchangers are titanium exchangers intended for use in particular REDUCE FOULING in demanding pool systems with mostly salt water. The use of titanium makes TI resistant to aggressive substances, such as salt, chlorine and fluorine, as well as high pressure and temperature. The design of the exchangers makes them suited to operate in high-flow systems. Corrugated tubes cause turbulent flow, which intensif ies heat HIGH VOLUME FLOW exchange and reduces the possibility...

 Open the catalog to page 9
HEAT EXCHANGERS POOL-10

STANDARD LOCATION OF CONNECTIONS K 1 ⁄ K 4   ―  inlet / outlet heat source K 3 ⁄ K 2   ―  nlet / outlet pool water i internal thread G11/2" Heat source temperature inlet Pool water temperature inlet Pool water Flow Heat source Heat exchange area Tube diameter Tube side capacity Shell side capacity Pressure drop Heat source All dimensions and technical data are approximate only and ma

 Open the catalog to page 10
HEAT EXCHANGERS POOL-11

JAG P L AT E & F R A M E H E AT E XC H A N G E R S From the passion for innovation a new product has been born – JAG Plate Heat Exchanger with inventive jagged pattern of a heating plate. Breaking new ground solution brings not only enhanced flow turbulence but also increased heat exchange area. Together it gives more compact, lighter but most of all more eff icient device which can be customized to your individual requirements. Highly eff icient JAG Plate Heat Exchanger will become a long-life dependable solution for your applications. HEAT TRANSFER ENHANCED FLOW TURBULENCE UP TO 10% LOWER PRESSURE...

 Open the catalog to page 11
HEAT EXCHANGERS POOL-12

METAL ROLLER SPECIAL CARRYING BAR PROFILE CONNECTION SIZE: 1 1 /4 " – 1 4 " PL ATE PACK BACK COVER PLATE LOCK WASHER FRONT COVER PLATE OTHER FRAME ELEMENTS MADE O F G A LVA N I Z E D O R STAINLESS STEEL ADDITIONAL FRONT FEET

 Open the catalog to page 12
HEAT EXCHANGERS POOL-13

JAG PL ATE REINVE NT E D FIVE POINT STELLAR SUSPENDING G A SK E TS PATENTED HYBRID LO CK SYSTEM TRIPLE PLATE New construction of the patented gasket features two locking methods and an optimized unique shape. The hybrid lock system makes the mounting easier, quicker, and more stable throughout the exchanger assembly process. The innovative shape provides superior sealing capacity even in high pressure applications. MODIFIED DISTRIBUTION AREA PATENTED HYBRID LOCK SYSTEM OPTIMIZED GASKET SEALING SURFACE ADDITIONAL REINFORCEMENT OF THE PLATE

 Open the catalog to page 13
HEAT EXCHANGERS POOL-14

STANDARD LOCATION OF CONNECTIONS – SINGLE PASS: K 1 ⁄ K 4   ― inlet / outlet heat source K 3 ⁄ K 2   ― inlet / outlet pool water Connection size STANDARD LOCATION OF CONNECTIONS – DOUBLE PASS: D 4 ⁄ K 4   ― inlet / outlet heat source K 3 ⁄ D 3   ― inlet / outlet pool water All dimensions and technical data are approximate only and may be changed without further notice. Water flow JAG Type The power of heat source Heat source temperature Pool volume Pool water temperature Source of heat

 Open the catalog to page 14

All HEXONIC CZ s.r.o. catalogs and technical brochures

  1. CIP

    13  Pages

  2. JAG SHIELD

    7  Pages

  3. JAD

    13  Pages

  4. DNA

    5  Pages

  5. LA21AS

    5  Pages

Archived catalogs

  1. Industrial

    7  Pages

  2. Oil Coolers

    11  Pages

  3. ST

    3  Pages

  4. JAD 2021

    15  Pages

  5. Dry cooler

    11  Pages

  6. DNA ECO

    1  Page

  7. Custom

    3  Pages

  8. HAD 2020

    3  Pages

  9. JAD 2020

    3  Pages

  10. P-line

    3  Pages

  11. PHE

    3  Pages

  12. Luna

    3  Pages

  13. Safe plate

    3  Pages

  14. R-line

    3  Pages

  15. L-line

    3  Pages

*Prices are pre-tax. They exclude delivery charges and customs duties and do not include additional charges for installation or activation options. Prices are indicative only and may vary by country, with changes to the cost of raw materials and exchange rates.