Catalog excerpts
POOL HEAT EXCHA N G ER S
Open the catalog to page 1POOL H E AT E XC H A N G E R S Special design of our pool heat exchangers boosts heat transfer and delivers better utilization of heat source. Equipped with straight tubes all of the models ensure low pressure loss thus saving energy. Corrugated straight tubes promote turbulent flow which further intensifies heat exchange and helps reduce fouling. Cutting-edge technology and durable materials such as titanium and stainless steel, make our heat exchangers resistant to corrosive environments. They can be used with all types of pool water – either treated or salt. OUTSTANDING RELIABILITY...
Open the catalog to page 2HEAT EXCHANGER TYPE Pool B Public pool Private pool Olympic-size pool Kids’ pool Salt water pool Water park HEAT EXCHANGER TYPE Heat source type B Condensing boiler Coal boiler Geothermal water Heat pump Solar system District heating D I A G R A M O F S A LT WAT E R P O O L WITH A HEXONIC POOL HEAT EXCHANGER possibility best choice
Open the catalog to page 3B pool heat exchangers are characterized by high thermal eff iciency. They are HIGH VOLUME FLOW the perfect solution in high-flow systems, in particular pool systems of different B type exchangers are shell and tube exchangers equipped with straight corrugated tubes. They can be used in systems with high medium flow in comparison to transferred thermal power. It is a proven solution for pool and solar systems or small oil preheating systems. COMPACT SIZE The use of corrugated tubes intensif ies heat exchange and increases self-cleaning possibilities. Compact, welded B type exchangers are...
Open the catalog to page 4Connection size Type K1, K4 STANDARD LOCATION OF CONNECTIONS K 1 ⁄ K 4 ― inlet / outlet heat source – internal thread K 3 ⁄ K 2 ― inlet / outlet pool water – internal thread Dimensions Heat exchange area Tube diameter Tube side capacity Shell side capacity
Open the catalog to page 5Heat source temperature inlet Pool water temperature inlet Pool water Flow Heat source Pool water Pressure drop Heat source All dimensions and technical data are approximate only and may be changed without further notice.
Open the catalog to page 6REV pool heat exchangers achieve very high heat exchange coeff icient thanks to the 3-pass tube bundle. UNIQUE 3-PASS TUBE BUNDLE ENABLES BETTER UTILIZATION OF THE HEAT REV heat exchangers are intended for use mainly in swimming pool installations. The main priority in their design was to improve heat exchange conditions. EXCEPTIONAL HEAT This was achieved by using the 3-pass design of the tube bundle, which results in better utilization of source thermal power. Additionally, thanks to the short path of pool water (heated medium) through the exchanger, the flow speed remains high. LITTLE...
Open the catalog to page 7STANDARD LOCATION OF CONNECTIONS K 1 ⁄ K 4 ― inlet / outlet heat source external thread G11/2" K 3 ⁄ K 2 ― nlet / outlet pool water i WORKING PARAMETERS Pool water temperature inlet Heat source temperature inlet Pool water Flow Heat source Heat exchange area Tube diameter Tube side capacity Shell side capacity Pressure drop Heat source All dimensions and technical data are approximate only a
Open the catalog to page 8TI titanium pool exchangers are intended for use in pool systems with salt water. CORRUGATED TUBES INTENSIFY HEAT EXCHANGE AND TI type exchangers are titanium exchangers intended for use in particular REDUCE FOULING in demanding pool systems with mostly salt water. The use of titanium makes TI resistant to aggressive substances, such as salt, chlorine and fluorine, as well as high pressure and temperature. The design of the exchangers makes them suited to operate in high-flow systems. Corrugated tubes cause turbulent flow, which intensif ies heat HIGH VOLUME FLOW exchange and reduces the...
Open the catalog to page 9STANDARD LOCATION OF CONNECTIONS K 1 ⁄ K 4 ― inlet / outlet heat source K 3 ⁄ K 2 ― nlet / outlet pool water i internal thread G11/2" Heat source temperature inlet Pool water temperature inlet Pool water Flow Heat source Heat exchange area Tube diameter Tube side capacity Shell side capacity Pressure drop Heat source All dimensions and technical data are approximate only and ma
Open the catalog to page 10JAG P L AT E & F R A M E H E AT E XC H A N G E R S From the passion for innovation a new product has been born – JAG Plate Heat Exchanger with inventive jagged pattern of a heating plate. Breaking new ground solution brings not only enhanced flow turbulence but also increased heat exchange area. Together it gives more compact, lighter but most of all more eff icient device which can be customized to your individual requirements. Highly eff icient JAG Plate Heat Exchanger will become a long-life dependable solution for your applications. HEAT TRANSFER ENHANCED FLOW TURBULENCE UP TO 10% LOWER...
Open the catalog to page 11METAL ROLLER SPECIAL CARRYING BAR PROFILE CONNECTION SIZE: 1 1 /4 " – 1 4 " PL ATE PACK BACK COVER PLATE LOCK WASHER FRONT COVER PLATE OTHER FRAME ELEMENTS MADE O F G A LVA N I Z E D O R STAINLESS STEEL ADDITIONAL FRONT FEET
Open the catalog to page 12JAG PL ATE REINVE NT E D FIVE POINT STELLAR SUSPENDING G A SK E TS PATENTED HYBRID LO CK SYSTEM TRIPLE PLATE New construction of the patented gasket features two locking methods and an optimized unique shape. The hybrid lock system makes the mounting easier, quicker, and more stable throughout the exchanger assembly process. The innovative shape provides superior sealing capacity even in high pressure applications. MODIFIED DISTRIBUTION AREA PATENTED HYBRID LOCK SYSTEM OPTIMIZED GASKET SEALING SURFACE ADDITIONAL REINFORCEMENT OF THE PLATE
Open the catalog to page 13STANDARD LOCATION OF CONNECTIONS – SINGLE PASS: K 1 ⁄ K 4 ― inlet / outlet heat source K 3 ⁄ K 2 ― inlet / outlet pool water Connection size STANDARD LOCATION OF CONNECTIONS – DOUBLE PASS: D 4 ⁄ K 4 ― inlet / outlet heat source K 3 ⁄ D 3 ― inlet / outlet pool water All dimensions and technical data are approximate only and may be changed without further notice. Water flow JAG Type The power of heat source Heat source temperature Pool volume Pool water temperature Source of heat
Open the catalog to page 14All HEXONIC CZ s.r.o. catalogs and technical brochures
-
LF heat exchanger applications
12 Pages
-
JR heat exchangers applications
13 Pages
-
DNA heat exchangers applications
24 Pages
-
JAG heat exchangers applications
28 Pages
-
JAD heat exchanger applications
24 Pages
-
Custom heat exchangers
15 Pages
-
Economizer HEXONIC DNA ECO
9 Pages
-
Heat exchangers HEXONIC RAD
5 Pages
-
HAD
7 Pages
-
DNA
5 Pages
-
JAD
13 Pages
-
Asymetric BPHE (en)
5 Pages
-
Dry coolers (EN)
11 Pages
-
HEXONIC KATALOG (EN)
17 Pages
-
BPHE
17 Pages
-
JAG SHIELD
7 Pages
-
Technical card R
3 Pages
-
Technical card Luna
2 Pages
-
BRAZED PLATE HEAT EXCHANGERS
15 Pages
Archived catalogs
-
JAG PLATE HEAT EXCHANGER
13 Pages
-
Oil Coolers
11 Pages
-
Pool
15 Pages
-
P-line
11 Pages
-
JAD
15 Pages
-
HAD
7 Pages
-
BPHE
13 Pages
-
Dry cooler
11 Pages
-
ST
3 Pages
-
L-line
3 Pages
-
DNA ECO
1 Pages
-
R-line
3 Pages
-
Luna
3 Pages
-
Shell and tube
3 Pages
-
Safe plate
3 Pages
-
Pool
15 Pages
-
P-line
3 Pages
-
PHE
3 Pages
-
L-line
3 Pages
-
JAD
3 Pages
-
Industrial
7 Pages
-
HAD
3 Pages
-
DNA
5 Pages
-
Custom
3 Pages
-
P-line
3 Pages