Catalog excerpts
RAD HEAT EXCHA N G ER S FO R G R OU ND S OURC E HEAT PU M PS
Open the catalog to page 1RAD SHELL AND COIL HE AT E XCHANGERS With a proven design and performance, RAD shell and coil heat exchangers are perfect for refrigerant applications, especially in ground source heat pumps. Direct refrigerant inlet into each of the heat exchanger tubes ensures uniform medium distribution. RAD has a high heat transfer coefficient and is designed for modern A2L refrigerants such as R32, R452B, R454B. With compact dimensions and vertical installation, the exchanger’s footprint is greatly reduced. RAD has been designed to work with pressures up to 45 bar. WITH WELL, RIVER, LAKE WATER EVEN...
Open the catalog to page 2WORKING PARAMETERS: SHELL SIDE (WATER) MAX. PRESSURE — 16 BAR COIL SIDE (REFRIGERANT) MAX. TEMPERATURE — 130°C TECHNICAL PARAMETERS: K 1 ⁄ K 4 ― inlet ⁄ outlet of refrigerant K 3 ⁄ K 2 ― inlet ⁄ outlet of water or glycol Dimensions Type Tube side volume
Open the catalog to page 3THE M A I N A PPLI CAT IO N O F RAD H E AT EXCH AN G E RS WATER GROUND SOURCE HEAT PUMP Water heat pumps with an open loop utilize water sourced from a well, lake, or even river to heat and cool your building. They extract water from one location, through heat exchangers in the heat pump to absorb energy from the water, and then deposit this cooler water into another location of the source. This solution is an alternative to relying on gas, coal and other non-renewable fuels. RAD shell and coil heat exchangers are perfect for installations where water from the ground heat source is fed...
Open the catalog to page 4All HEXONIC CZ s.r.o. catalogs and technical brochures
-
LF heat exchanger applications
12 Pages
-
JR heat exchangers applications
13 Pages
-
DNA heat exchangers applications
24 Pages
-
JAG heat exchangers applications
28 Pages
-
JAD heat exchanger applications
24 Pages
-
Custom heat exchangers
15 Pages
-
Economizer HEXONIC DNA ECO
9 Pages
-
HAD
7 Pages
-
DNA
5 Pages
-
JAD
13 Pages
-
Asymetric BPHE (en)
5 Pages
-
Dry coolers (EN)
11 Pages
-
HEXONIC KATALOG (EN)
17 Pages
-
BPHE
17 Pages
-
JAG SHIELD
7 Pages
-
HEAT EXCHANGERS POOL
15 Pages
-
Technical card R
3 Pages
-
Technical card Luna
2 Pages
-
BRAZED PLATE HEAT EXCHANGERS
15 Pages
Archived catalogs
-
JAG PLATE HEAT EXCHANGER
13 Pages
-
Oil Coolers
11 Pages
-
Pool
15 Pages
-
P-line
11 Pages
-
JAD
15 Pages
-
HAD
7 Pages
-
BPHE
13 Pages
-
Dry cooler
11 Pages
-
ST
3 Pages
-
L-line
3 Pages
-
DNA ECO
1 Pages
-
R-line
3 Pages
-
Luna
3 Pages
-
Shell and tube
3 Pages
-
Safe plate
3 Pages
-
Pool
15 Pages
-
P-line
3 Pages
-
PHE
3 Pages
-
L-line
3 Pages
-
JAD
3 Pages
-
Industrial
7 Pages
-
HAD
3 Pages
-
DNA
5 Pages
-
Custom
3 Pages
-
P-line
3 Pages