DRY COOLERS INDUSTRIAL COOLING SYSTEMS , AIR CONDITIONING DATA CENTRE COOLING SYSTEMS POWER PLANTS LARGE VOLUME BIOGAS PLANTS EFFICIENT COOLING METHOD ABILITY TO USE VARIOUS MEDIA CHEAPEST WASTE HEAT DISPERSION METHOD HIGH PERFORMANCE SYSTEM OPERATION
Open the catalog to page 3STARTING FROM DECIBEL AXIAL FANS COVERS CONFORMING COMPLIANT WITH
Open the catalog to page 4CASING MADE OF THICK CARBON STEEL COATED WITH ZINC (ZINTEC), WET PAINTED OR POWDER COATED — O P P E R T U B E S Ø 1 2 M M ( 0 . 4 7 I N ) C — A F F L E – T U B E S T A B I L I Z I N G S Y S T E M B FOR THE INCREASE IN THE SERVICE LIFE OF THE DEVICE — O P P E R C O M P O N E N T S S O L D E R E D C WI T H H I G H S I LVE R CO N T E N T S O L D E R SEVERAL COLOUR DESIGNS AND CORROSION CLASSES AVAILABLE (STANDARD C3 CORROSION PROTECTION CLASS) — A L U M I N I U M F I N S HIGH DURABILITY OF MAIN COMPONENTS, SUCH AS HEAT EXCHANGER, CASING, FANS
Open the catalog to page 5E F F ICIEN CY M OST ECON OM I CAL WAY TO DIS S I PATE EXCE S S H E AT DRY COOLERS OFFER EFFICIENT COOLING TECHNOLOGY WITH LOW ENERGY CONSUMPTION.
Open the catalog to page 6THE ADIABATIC SYSTEM Allows the operation of the dry cooler even when the ambient temperature is higher than the temperature of the process medium. It increases the relative humidity of the air, thus lowering its temperature.
Open the catalog to page 8HORIZONTAL MODELS Dimensions Type * Spacing between outer legs of the dry cooler. Number of legs depend on a type of dry cooler. All dimensions and technical data are approximate only and may be changed without further notice. * Spacing between outer legs of the dry cooler. Number of legs depend on a type of dry cooler. All dimensions and technical data are approximate
Open the catalog to page 9WORKING PARAMETERS VERTICAL MODELS MIN. ALLOWABLE TEMPERATURE OF THE PROCESS LIQUID — - 2 0 ° C ⁄ - 4 ° F MAX. ALLOWABLE TEMPERATURE EXEMPLAR DESIGNATION than longer) sound intensity: N – n ormal, single module length 1500 mm (59") S – lim, single module length s 1250 mm (49.2") 50 – f requency 50Hz D – delta 400V Y – star 400V J – single phase 230V E – EC direct current motor * Spacing between outer legs of the dry cooler. Number of legs depend on a type of dry cooler. All dimensions and techni
Open the catalog to page 1013 Pages
7 Pages
15 Pages
17 Pages
15 Pages
7 Pages
9 Pages
5 Pages
13 Pages
5 Pages
5 Pages
3 Pages
2 Pages
15 Pages
3 Pages
7 Pages
11 Pages
3 Pages
15 Pages
13 Pages
7 Pages
15 Pages
13 Pages
11 Pages
15 Pages
1 Page
3 Pages
3 Pages
3 Pages
3 Pages
3 Pages
3 Pages
3 Pages
3 Pages
3 Pages