INDUSTRIAL PROCESSES DATA CENTRE COOLING SYSTEMS LARGE VOLUME AIR CONDITIONING SYSTEMS RENEWABLE ENERGY BIOGAS PLANTS HEAT AND POWER PLANTS INDUSTRIAL COOLING SYSTEMS, AIR CONDITIONING large volume air conditioning systems data centre cooling systems remote radiator systems e.g. co-generation engine, diesel generator engine, gas generator and turbine heat dissipation industrial liquid cooling e.g. dissipation of heat from process fluids, thermal oils, waterglycol, hydraulic oils industrial machinery cooling systems e.g. vacuum and atmospheric brazing furnaces, induction heat treatment, plastic...
Open the catalog to page 3EANS V I R O N M E N T N F Compliant with starting from acoustic intensity high efficiency, low decibel axial fans with low maintenance protective fan covers conforming to EN294
Open the catalog to page 4baffle - tube stabilizing system for the such as heat exchanger, casing, fans and electronics increase in the service life of the device • high durability of main components, copper components soldered with high silver content solder aluminium fins fin spacing 2,5 mm, 2,3 mm or 2,5 mm (0.83”, 0.91” or 0.98”) depending on casing made of thick carbon steel coated with zinc (Zintec), wet painted or powder coated • several colour designs and corrosion classes available (standard C3 corrosion pro
Open the catalog to page 5Dry coolers offer efficient cooling technology with low energy TO DISSIPATE EXCESS HEAT 10
Open the catalog to page 6SPECIFIC NEEDS on/off switch PID controller with frequency converter PLC controller with touchscreen off switches for individual fans adiabatic cooling system vibration dampers to absorb vibrations of the device weatherproof electrical cabinet
Open the catalog to page 7The adiabatic system allows the operation of the dry cooler even when the ambient temperature is higher than the temperature of the process medium. It increases the relative humidity of the air, thus lowering its temperature.
Open the catalog to page 8* Spacing between outer legs of the dry cooler. Number of legs depend on a type of dry cooler. * Spacing between outer legs of the dry cooler. Number of legs depend on a type of dry cooler. All dimensions and technical data are approximate only and may be changed without further notice. All dimensions and technical data are approximate only and may be changed without further notice.
Open the catalog to page 9WORKING PARAMETERS PRESSURE OF THE PROCESS LIQUID EXAMPLE DESIGNATION Dry cooler Type SD - SECESPOL dry cooler F - flat V - vertical 6A35 - geometry of the heat exchanger * Spacing between outer legs of the dry cooler. Number of legs depend on the type. All dimensions and technical data are approximate only and may be changed without further notice. 50 - frequency 50 Hz D - delta 400V Y - star 400V J - single phase 230V E - EC direct current motor 1x2 - number of fans, e.g. 1 in series x 2 in parallel (wider than longer) LL - very low sound intensity L - low sound intensity M - medium...
Open the catalog to page 1013 Pages
7 Pages
15 Pages
17 Pages
15 Pages
7 Pages
9 Pages
5 Pages
13 Pages
5 Pages
5 Pages
11 Pages
3 Pages
2 Pages
15 Pages
3 Pages
7 Pages
11 Pages
3 Pages
15 Pages
13 Pages
7 Pages
15 Pages
13 Pages
15 Pages
1 Page
3 Pages
3 Pages
3 Pages
3 Pages
3 Pages
3 Pages
3 Pages
3 Pages
3 Pages