Asymetric BPHE (en)
5Pages

{{requestButtons}}

Catalog excerpts

Asymetric BPHE (en) - 2

I F YO U L O O K F O R B E T T E R PERFORMANCE AND MORE EFFICIENCY I N YO U R H E AT I N G I N S TA L L AT I O N – W E TA K E U P T H E C H A L L E N G E ! HIGHER CAPACITY HIGHER The Hexonic asymmetric brazed plate heat exchanger is designed especially for heating applications. Special system of the channels ensures maximum heat transfer efficiency on the higher flow rate side with a minimum pressure drop on the secondary circuit. The biggest advantage of the asymmetric heat exchanger is its compact size and the possibility of using lower power pumps in central heating systems. LOWER...

Open the catalog to page 2
Asymetric BPHE (en) - 3

WORKING PARAMETERS MAX. PRESSURE — 16 BAR MAX. TEMPERATURE — 150°C MIN. TEMPERATURE — -195°C Asymmetric plate heat exchangers allow independent optimization of both fluids for maximum thermal efficiency and economy. The unique plate design allows for operation in conditions where one of the media has much higher flow rate. ACTIVE FRONT PLATE FORMS LESS WATER PRESSURE DROPS INCREASED MAXIMUM WATER FLOW HIGHER FLOW TURBULENCE

Open the catalog to page 3
Asymetric BPHE (en) - 4

GAS-FIRED BOILERS RESIDENTIAL DISTRICT HEATING SUBSTATION Gas-fired boilers are heating devices characterized by a high efficiency and performance. A residential substation, also called individual apartment substation, Gas-fired combination boilers have been designed in a way that enables is a compact device providing heat to a single apartment. It transfers the unit to heat the building and supply domestic hot water (DHW) the heat from a local boiler room or a district heating substation heated in a flow system. If hot water is needed, the boiler will switch supplied by a city heating grid...

Open the catalog to page 4

All HEXONIC CZ s.r.o. catalogs and technical brochures

  1. HAD

    7 Pages

  2. DNA

    5 Pages

  3. JAD

    13 Pages

  4. BPHE

    17 Pages

  5. JAG SHIELD

    7 Pages

Archived catalogs

  1. Oil Coolers

    11 Pages

  2. Pool

    15 Pages

  3. P-line

    11 Pages

  4. JAD

    15 Pages

  5. HAD

    7 Pages

  6. BPHE

    13 Pages

  7. Dry cooler

    11 Pages

  8. ST

    3 Pages

  9. L-line

    3 Pages

  10. DNA ECO

    1 Pages

  11. R-line

    3 Pages

  12. Luna

    3 Pages

  13. Safe plate

    3 Pages

  14. Pool

    15 Pages

  15. P-line

    3 Pages

  16. PHE

    3 Pages

  17. L-line

    3 Pages

  18. JAD

    3 Pages

  19. Industrial

    7 Pages

  20. HAD

    3 Pages

  21. DNA

    5 Pages

  22. Custom

    3 Pages

  23. P-line

    3 Pages