Specifications:
- Film: Homogenous coloured PVC
- Film Thickness: 0.5 mm (Calliper Method)
- Total Applied Thickness: 0.57 mm (Calliper Method)
- Adhesive Type: Modified solvent acrylic
- Adhesive Thickness: 0.07 mm (Calliper Method)
- Peel Adhesion to Stainless Steel: 25.2 N/25mm (20 min dwell), 28.0 N/25mm (24 hr dwell) (FINAT FTM1)
- Tensile Strength: 158 N/25mm (Lloyd T5100 with 500N load cell)
- Elongation at Break: 294% (Lloyd T5100 with 500N load cell)
- Colour Options: Standard colours include black, orange, red, green, white, and yellow. Custom Pantone or RAL colours available based on MOQ.
- Temperature Range: -30ºC to +70ºC
- Maximum Roll Size: 1260mm x 100m

Friction Test Results:
- Dry Surface Pendulum Test: 102
- Wet Surface Pendulum Test: 24
- DIN51130: R10
Tests conducted at an independent friction testing laboratory.

Light Reflectance Value (LRV) Test Results:
- H6905R (Red): Av. LRV 15.38, Range 0.47
- H6905O (Orange): Av. LRV 23.07, Range 0.25
- H6905Y (Yellow): Av. LRV 52.33, Range 0.96
- H6905V (Green): Av. LRV 14.93, Range 0.78
- H6905B (Blue): Av. LRV 6.63, Range 0.4
- H6905W (White): Av. LRV 78.14, Range 0.78
- H6905N (Black): Av. LRV 3.13, Range 0.78
- H6905D (Black): Av. LRV 3.18, Range 0.75
- H6905D (Yellow): Av. LRV 62.88, Range 2.08
- H6905A (Red): Av. LRV 25.82, Range 1.14
- H6905A (White): Av. LRV 78.55, Range 1.93
Test procedure follows Lucideon In House Test Method WW22, compliant with BS.8493:2008+A1:2010.

All data is for reference only. Original test data available on request.
See more

Catalog excerpts

PermaLean Data Sheet-1

HESKINS .■4NT-SL P SOLUTIONS [email protected] www.permastripe.co.uk 25/03/2022 The above tests were conducted in accordance with Pendulum, the tests were conducted at a recognised independent friction testing laboratory, and copy certificates are available on request.

 Open the catalog to page 1
PermaLean Data Sheet-2

HESKINS ANTI-SL P SOLUTIONS [email protected] www.permastripe.co.uk 25/03/2022 The test procedure follows Lucideon In House Test Method WW22, and complies with the requirements of All the above data is for reference only.

 Open the catalog to page 2
*Prices are pre-tax. They exclude delivery charges and customs duties and do not include additional charges for installation or activation options. Prices are indicative only and may vary by country, with changes to the cost of raw materials and exchange rates.