
Catalog excerpts

Versatile due to its modular structure; completely maintenance-free; modern and exceptionally functional design; equipped with electronic heater element and device protection (types S, M, L, XL and Compact) PRACTICE-ORIENTED Approved design and dimensions; flexible due to graduated heating capacities and voltages; device protection evaluable with floating contact for the types L and XL; by modifying the basic versions, most applications can be realized. Usual service within 24 hours; simple heater element replacement by the user. Basic version: 1. control (output control) via internal...
Open the catalog to page 2
Unmatched in air volume and pressure with minimum dimensions! Standard continuous temperature adjustment and an electronic heater element and device protection for this device, as wellas continuous speed adjustmentfor variable air volumes. Temperature and speed are set with the potentiometer, optionally, both values can be set with an external control (e.g. PLC). Please observe the modification options listed on page 2 above. A query of the speed for visualisation, control or monitoring the process safety is also possible. Due to its broad accessory range, the device can be used in multiple...
Open the catalog to page 3
The most convenient orresl The brushless motor will enable maintenance-free continuous operation for these devices in the harshest industrial applications. Therefore, our hot air blowers are perfectly suited for installation in e.g. shrink tunnels and machines where an even hot air stream is important. Standard version: • continuous temperature setting via the potentiometer on the device • integrated heater element and device protection Special versions: • external control of the heating operation (digital control signal: PWM • external control of the blower speed (air volume) (only...
Open the catalog to page 4
The smallest one with the highest capacity! Versatile use due to small size, easy installation due to internal thread M16 in the blow-out opening. The integrated thermocouple type „K" is standard for these devices. XS20 Except wear parts. Subject to technical modifications and errors. Other voltages and output values on request. Images may differ from the original! 5
Open the catalog to page 5
The short one for direct installation! With mounting thread directly in the housing. Smallest installation height despite air hose with internal connection line. The perfect device for confined spaces and installation positions. Article number Subject to technical modifications and errors. Other voltages and output values on request. Images may differ from the original! Except wear parts.
Open the catalog to page 6
The one with small heater element! The S21 is equipped with an internal heater control via a potentiometer by default. The availability of 3 basic versions and several modifications as well as e.g. an internal PID control, the device meets individual requirements. Article number/ Except wear parts. Subject to technical modifications and errors. Other voltages and output values on request. Images may differ from the original!
Open the catalog to page 7
The only one!! No other air heater provides this capacity range with these small dimensions. For projects where similar devices such as type S21 are too small and type S36 is too big, type S32 fills the existing gap! The availability of 3 basic versions and several modifications as well as e.g. an internal PID control, the device meets individual requirements. Article number/ Subject to technical modifications and errors. Other voltages and output values on request. Images may differ from the original! Except wear parts.
Open the catalog to page 8
The most desired! Its capacity range in proven quality covers a wide application range. The availability of 3 basic versionsand several modifications as well as e.g. an internal PID control, the device meets individual requirements. Article number/ Except wear parts. Subject to technical modifications and errors. Other voltages and output values on request. Images may differ from the original! 9
Open the catalog to page 9
The universal one! The double-insulated device forhigh requirements concerning theairvolume. The availability of 3 basic versionsand several modifications as well as e.g. an internal PID control, the device meets individual requirements. Subject to technical modifications and errors. Other voltages and output values on request. Images may differ from the original! Except wear parts.
Open the catalog to page 10
Type L62from 4'300 watt to 13'000 watt w The slim one! This device with slim pipe adapter and a maximum temperature of 700°C. The perfect air heater for positions difficult to access. As a standard, the L62 provides an evaluation of the device protection with an internal relay with a changeover contact for 230 volts and max. 1 amp. The availability of 3 basic versions and several modifications as well as e.g. an internal PID control, the device meets individual requirements. Except wear parts. Subject to technical modifications and errors. Other voltages and output values on request. Images...
Open the catalog to page 11
Type XL92from 5700 watt to 25'000 watt The highest capacity! The perfect choice for the highest capacity and air volume requirements. Capacity up to 25 kW for very large air volumes, packed in a compact air heater. As a standard, the XL92 provides an evaluation ofthe device protection with an internal relay with a changeover contact for 230 volts and max. 1 amp. The availability of3 basic versionsand several modifications as well as e.g. an internal PID control, the device meets individual requirements. Subject to technical modifications and errors. Other voltages and output values on...
Open the catalog to page 12
Heat resistant up to 180°C! Both devices are equipped with flanges on the inlet and outlet side to integrate them easily into a pipe system. Inlet temperatures of max. 180°C can be supplied at the inlet in recirculated air operation without causing damages. For air supply, our medium-pressure blowers with simple temperature resistor can be used. You can find them on the pages 18 and 19. The pipe air heaters are designed for a high system pressure of600,000 Pa (6 bar) and can therefore also be used in closed systems. The air heaters of this type are not equipped with electronics due to the...
Open the catalog to page 13All Herz GmbH catalogs and technical brochures
-
LiiOn
2 Pages
-
Apparatus construction
28 Pages
-
Heating & Edging Machines
12 Pages
-
Roof- welding systems
12 Pages
-
welding wire
2 Pages
-
Fillet weld feeder
1 Pages
-
Power pressure roller
1 Pages
-
Tarpaulin welding systems
6 Pages
-
Table-top Bending Template
1 Pages
-
ProtOn AIr
1 Pages
-
XL92HT
1 Pages
-
Floor welding systems
8 Pages
-
Civil Engineering
12 Pages
-
Extrusion welding systems
12 Pages
-
Board and pipe welding machines
16 Pages
-
Test Equipment & Accessories
8 Pages