HZ-HA-371

HZ-HA-371

HZ-HA-371

Product catalog summary
Overview: The HZ-FA-371 is a high sensitivity acoustic imaging camera designed for detecting partial discharge issues in high-voltage electrical systems and gas leaks in compressed gas systems. It features an array of 128 MEMS microphones and covers frequencies from 2kHz to 65kHz, allowing for precise sound source localization and advanced diagnostics.
Key Features:
  • 128 MEMS Microphones for enhanced detection capabilities.
  • Detection range from 2kHz to 65kHz.
  • Supports multiple source detection with real-time sound source localization.
  • Real-time prediction of partial discharge types and estimation of gas leak rates and costs.
  • IP68 protection level for robust environmental resistance.
Specifications:
  • Acoustic Image Resolution: 800*480/1920*1080.
  • Dynamic Range: 30dB to 120dB.
  • Detection Distance: 0.3m to 50m (1ft to 164ft).
  • Sampling Rate: 130kHz.
  • Camera Field of View (FOV): 65°.
  • Imaging Frame Rate: 25FPS.
  • Focal Length: 3.9mm.
  • Video Resolution Options: 2592*1944, 1920*1080, 1280*720, 720*480, 640*480.
  • Video File Format: AVI.
  • Transmission: RJ45.
  • Power Supply: DC 12V/3A.
  • Weight: Approx. 900g.
  • Dimensions: 135mm x 171.43mm x 48mm.
  • Operating Temperature Range: -20℃ to 70℃.
  • Storage Temperature Range: -30℃ to 60℃.
Application Scenarios: The HZ-FA-371 is suitable for partial discharge detection and air leakage detection, with anti-explosion certification ExiblICT6Gb:ExibllICT80℃ Db.
Leak Rate Detection: The system can detect leak rates of >0.035 l/min at 120KPa and 0.3m, >0.067 l/min at 300KPa and 3m, and >0.09 l/min at 300KPa and 5m.
See more

Catalog excerpts

HZ-HA-371-1

HZ-FA-371 Fixed Acoustic Imaging Camera Key Feature • • • • • • • HZ-FA-371 is a high sensitivity acoustic imaging system specifically engineered for the detection of partial discharge issues in high-voltage electrical systems and gas leaks in compressed gas systems. Boasting an array of 128 MEMS microphones, this sophisticated system excels in detecting and quantifying various instances of partial discharge while also providing accurate estimations of gas leak rates and associated costs. Covering audible and ultrasonic frequencies from 2kHz to 65kHz, it facilitates precise sound source localization for advanced diagnostics. With high performance design, FA371 supports 7*24h monitoring and can be installed on robot or any fixed place. 128 MEMS Microphones 2kHz ~ 65kHz detection Supports multiple source detection Real-time sound source localization Real-time partial discharge type prediction Real-time estimate gas leak rate, lea

 Open the catalog to page 1
HZ-HA-371-2

Acoustic Microphones 128 channel MEMS microphones Acoustic Image Resolution Dynamic Range of Sensors Sampling Rate Imaging Frame Focal Length Microphone Self-diagnosis General Encord Video Resolution Video File Format Power Supply Protection Level Working Temperature Range Storage Temperature Range Application Scenarios Partial discharge detection Air leakage detection. Stream Formats Leak Rate