Ultrabond 55391

Ultrabond 55391

Ultrabond 55391

Product catalog summary
Product Description
Hernon Ultrabond 55391 is a UV curable adhesive known for its excellent impact resistance and adhesion to various substrates including composites, metals, glass, ceramics, and plastics such as polyester, PVC, cellulose acetate, and nylon.
Product Benefits
  • UV fluorescence for in-process inspection.
  • Color change from blue to clear after UV exposure for process verification.
  • 100% solid system with no solvents.
  • Excellent adhesion and environmental resistance.
  • Good gap filling properties and no shrinkage.
  • Rapid room temperature cure.
Typical Properties (Uncured)
  • Chemical Type: Modified Acrylic Ester
  • Appearance: Light blue liquid
  • Specific Gravity @ 25°C: 1.10
  • Viscosity @ 25°C: 3500 to 5000 cP
Typical Curing Performance
Ultrabond 55391 cures rapidly at room temperature when exposed to high intensity UV light (365 nm). Fixture time on glass is 5 seconds, and tack-free time is less than 20 seconds.
Typical Properties (Cured)
  • Coefficient of thermal expansion: 80 × 10-6 K-1
  • Coefficient of thermal conductivity: 0.1 W/(m·K)
  • Hardness: Shore A 70
  • Temperature range: -55 to 135°C (-65 to 275°F)
Electrical Properties
  • Dielectric Strength: 36 kV/mm
  • Dielectric Constant at 1 kHz: 4.25
  • Dissipation Factor at 1 kHz: 0.03
  • Volume Resistivity: 1.7 x 1015 Ω·cm
General Information
This product is not recommended for use in pure oxygen or oxygen-rich systems and should not be used as a sealant for chlorine or other strong oxidizing materials. For safe handling, consult the MSDS.
Factors Affecting UV Curing
  • Dark surfaces and thicker films require longer cure times.
  • Full range UV lamps provide faster cures.
  • Light intensity decreases with distance from the UV source.
  • Some clear plastics may contain UV inhibitors.
Precautions When Using UV Lamps
  • Never look directly at the UV source.
  • Wear protective UV goggles and clothing.
  • Use in a well-ventilated area to avoid ozone exposure.
Storage
Store in a cool, dry location between 46°F to 82°F (8°C to 28°C). Do not return unused material to the original container to prevent contamination.
Dispensing Equipment
Hernon offers a range of semi and fully automated dispensing equipment. Contact Hernon Sales for more information.
Disclaimer
The information provided is based on reliable data, but no guarantee of accuracy is made. Users should conduct their own tests to determine product suitability for their operations. Hernon's Quality Management System is ISO 9001 registered.
See more

Catalog excerpts

Ultrabond 55391-1

High Performance Adhesives and Sealants Technical Data Sheet December 2009 Ultrabond® 55391 Product Description Hernon® Ultrabond® 55391 is a UV curable adhesive product that provides excellent impact resistance, and adhesion to a wide selection of substrates including composites, metals, glass, ceramics, and plastics such as polyester, PVC, cellulose acetate, and nylon. Product Benefits • UV fluorescence for in-process inspection • Color changes from blue to clear after UV exposure for process verification • 100% solid system (no solvents) • Excellent adhesion to a variety of surfaces • Excellent environmental resistance • Good gap filling properties • No shrinkage due to solvent evaporation • Rapid room temperature cure Typical Properties (Uncured) Typical Properties (Cured) General Information This product is not recommended for use in pure oxygen and/or oxygen rich systems and should not be selected as a sealant for chlorine or other strong oxidizing materials. For safe handling information on this product, consult the Material Safety Data Sheet (MSDS). Factors Affecting UV Curing • Dark surfaces lengthen cure time. • Full range (UV-A, B & C) lamps provide faster cures than filtered sources. • All UV sources degrade with use. Check output with a radiometer. • Thicker films require longer cures. • Light intensity decreases as distance from UV source increases. • Some clear plastics may contain UV inhibitors.

 Open the catalog to page 1
Ultrabond 55391-2

Hernon Technical Data Sheet Ultrabond® 55391 Page 2 of 2 Precautions When Using UV Lamps • Never look directly at UV source. • Wear protective UV goggles • Do not expose bare skin to high intensity UV light. • Wear protective clothing. • Use in a well-ventilated area. Some UV sources generate ozone. Provide shielding around high intensity UV sources. • High intensity UV sources generate heat. Take appropriate precautions. Storage Ultrabond® 55391 should be stored in a cool, dry location in unopened containers at a temperature between 46°F to 82°F (8°C to 28°C) unless otherwise labeled. Optimal...