1. Catalogs
  2. Hermann Sewerin GmbH
  3. Multitec BioControl

Multitec BioControl

Multitec BioControl

Multitec BioControl

Product catalog summary
Overview: The Multitec BioControl® is a combined stationary and mobile measuring device designed to determine the composition and volume of biogas, sewer gas, and landfill gas. It aims to optimize processes for electricity production by maximizing methane output while minimizing harmful gas components.
Specifications: The system can measure gas composition and volume at up to eight locations, including fermenters and desulphurisers. It compensates for pressure, temperature, moisture, and gas composition to ensure precise analysis. The device operates with a power supply of 24 V DC.
System Components: The system includes a fixed installation and a mobile gas measuring device, the Multitec 540. The fixed installation is low maintenance, requiring regular checks for dirt on sensors. The mobile device allows for easy maintenance and can be serviced without disrupting operations.
Measurement Capabilities: The Multitec 540 can measure up to five gases simultaneously using infrared and electrochemical sensors. It features a large screen for easy parameter reading and is suitable for biogas plants, waste disposal sites, and sewage plants.
Features: The device includes a large color touch screen, password-protected settings, continuous self-testing, and remote maintenance capabilities. It saves measurement values and settings autonomously on a USB stick.
Product Variants: Variants include Multitec BioControl.1, .4, and .8, indicating the number of measurement locations supported. The Multitec 540 is the mobile component, equipped with infrared sensors for methane and carbon dioxide, and electrochemical sensors for other gases.
Technical Details: The Multitec 540 offers a measuring range of 0.0 – 100% vol. for methane and carbon dioxide, and specific ranges for other gases like oxygen and hydrogen sulphide. It features a transflective display for readability in sunlight and is powered by replaceable batteries with a minimum seven-hour life.
Safety and Certification: The device is explosion-proof and comes with an EC type-examination certificate. It is designed for safe use in potentially explosive environments.
Contact Information: For further details and quotations, contact Hermann Sewerin GmbH.
See more

Catalog excerpts

Multitec BioControl-1

Combined stationary measuring device with mobile gas meter

 Open the catalog to page 1
Multitec BioControl-2

Multitec ® BioControl Determines the composition and volume of biogas, sewer gas and landfill gas All plant operators producing electricity from biogas, sewer gas or landfill gas aim to optimise processes and thus ensure greater efficiency – in other words, obtain as much methane as possible. At the same time, however, harmful components in the gas need to be kept to a minimum. Only constant monitoring of the gas composition in a plant can indicate changes before it is too late and thereby prevent prolonged outages. For example, if there is a warning of too much sulphur at the measurement location...

 Open the catalog to page 2
Multitec BioControl-3

Multitec ® BioControl One system for stationary and mobile measurements The Multitec ® BioControl is a combined measuring device consisting of the Multitec ® BioControl fixed installation and a mobile gas measuring device, namely the Multitec ® 540. Depending on the version of Multitec ® BioControl, the gas composition and volume can be automatically measured and monitored at up to eight measurement locations. The Multitec ® 540 measures the values at the individual measurement locations sequentially. The values are transferred to the Multitec ® BioControl via an interface. The mobile gas measuring...

 Open the catalog to page 3
Multitec BioControl-4

Multitec ® 540 as a mobile gas measuring device The Multitec ® 540 is a gas measuring device for monitoring gas mixtures that are formed in biological processes. It can measure the concentration of up to five gases in the gas mixture simultaneously. The device is fitted with infrared sensors for measuring methane and carbon dioxide as standard. It can also be fitted with electrochemical sensors. The use of infrared measuring technology for methane and carbon dioxide eliminates erroneous results caused by interaction with other gases. The Multitec ® 540 is, therefore, ideal for use in biogas plants...

 Open the catalog to page 4

All Hermann Sewerin GmbH catalogs and technical brochures

  1. SR-LD 800/200

    4  Pages

  2. Stethophon 04

    2  Pages

  3. SeCuRi® SAT

    2  Pages

  4. SeCorr 300

    4  Pages

  5. Multitec 560

    2  Pages

  6. Multitec 540

    2  Pages

*Prices are pre-tax. They exclude delivery charges and customs duties and do not include additional charges for installation or activation options. Prices are indicative only and may vary by country, with changes to the cost of raw materials and exchange rates.