Catalog excerpts
herborner.ηeo BEST EFFICIENCY
Open the catalog to page 1herborner.ηeo Optimal efficiency And therefore maximum energy savings The requirements profile of today's pure water pumps is always unique for each system. In addition, it requires flexibility when it comes to controlling the pumps. For exactly this reason it is important to be able to use the right pump with the suitable drive for every project application. Until now, this was only possible for certain operating points along the pump's characteristic curve. This is changed fundamentally with the new herborner.ηeo pump generation. The most important argument for using herborner.ηeo pumps...
Open the catalog to page 3Example New motor efficiency output curve New additional area of application for pumps The conchoids show the pump efficiency course Opera tion w Opera tion w Previous characteristic pump curves Previous optimal state for 5.5 kW pump with 70% degree of efficiency Example for 5.5 kW pump: Previous optimal efficiency level: 70% New efficiency with full impeller diameter according to shell curve: 90% => Hydraulic optimisation of the efficiency by 20%! INNOVATION Cost savings as a result of lower investment and energy costs. classic pumps
Open the catalog to page 4herborner.ηeo Impressive pump efficiency Eco-friendly products Thanks to our experience in pump technology, our further developments are innovative and define the market. Saving on stainless metals by substituting materials using our own coating technology developed in-house is particularly eco-friendly. We want to stay the forerunner when it comes to sustainability and think about the future when we develop our products, much like with the herborner.ηeo. Maximum efficiency increase Using the efficiency increase in the pump hydraulics with the development of the herborner.ηeo series, new...
Open the catalog to page 5IE2 to IE5 correspond to standardized energy efficiency classes classic pumps
Open the catalog to page 6herborner.ηeo Intelligent motor efficiency The latest motor technology with frequency converter All of the pumps of the herborner.ηeo series have been developed as "all-round products". With regard to the European directives on eco-friendly energy use, we are combining our herborner.ηeo pumps with permanent magnetic motors IE5 and specially customized frequency converters. IE5 currently corresponds to the highest energy efficiency class for motors, while the converter permits the optimum control of the system's requirements. It is not possible to make pumps any more energy-optimised than...
Open the catalog to page 7herborner.ηeo Most efficient water transport Flow-optimised surfaces are perfectly smooth Completely smooth-coated from the inside, the herborner.ηeo series conveys the medium with the greatest energy efficiency. This efficiency reduces energy costs by up to 15-20% compared to conventional pumps. Equipped with 100% corrosion protection, our pumps also offer the best hygiene protection. The possibility of any adhesions is as good as eliminated. Maximum impeller diameter puts the pressure on In the pumps of the herborner.ηeo series, the impeller diameter in the pump housing is designed with...
Open the catalog to page 9herborner.ηeo Brilliant operation Easy commissioning The pre-configured herborner.ηeo pumps are optimally prepared for commissioning. The flange position can be selected variably according to requirements. Fast adjustment to operating point In conjunction with the required pump power output, the frequency converter can easily regulate the motor speed. This is done with just a few hand motions. In general, pre-parameterization is done before delivery. Time-saving service The combination of pump, motor and frequency, each of which are attuned to one another, allows for generous service time...
Open the catalog to page 11herborner.ηeo Your Team for Success Herborner pumps are versatile and reliable. Ready for every task in systems technology, the herborner.ηeo pumps complement each other perfectly. From a power point of view, herborner.ηeo pumps have the maximum level of efficiency. GHEST HI herborner.X ηeo Ideal for use as a circulation pump with integrated hair and fibre separator. Plus: Easy-to-clean filter. herborner.F ηeo Ideal for the versatile use of a block pump in the complex world of systems technology. herborner.D ηeo The inline block pump is ideal for use as a pressure increasing pump for direct...
Open the catalog to page 13herborner.ηeo Checklist for maximum efficiency Smooth coating – High efficiency Thanks to the 100% smooth coating of the entire pump hydraulics system, optimum flow conditions are given. The flow of the medium through this is practically flawless. In addition, the "HPC" coating guarantees continuous corrosion protection. Life cycle optimised • Long-term use thanks to high product quality • Best operating adjustment with maximum efficiency • Outstanding value of life cycle costs and thus low overall costs for the operator Greatest impeller diameter The smooth-coated and thereby enhanced...
Open the catalog to page 15Herborner Pumpentechnik GmbH & Co KG Littau 3-5 DE-35745 Herborn Germany Phone: +49 (0) 27 72 / 933-0 Fax: +49 (0) 27 72 / 933-100 Email: info@herborner-pumps.com Special solutions The customisation of special pumps is one of our performance features. We are here for you - competent and personal. Our decades of experience in development and our onsite foundry form the basis of our ability to adapt to the requirements of individual projects. The technology needed for perpetual innovation provides our customers with the clear advantage of optimised solutions especially tailored to each unique...
Open the catalog to page 16All Herborner Pumpentechnik GmbH & Co KG catalogs and technical brochures
-
herborner.F - english
16 Pages