1. Catalogs
  2. heol design
  3. T200 PTP Time Station, with PoE

T200 PTP Time Station, with PoE
1 /6Pages

T200 PTP Time Station, with PoE

T200 PTP Time Station, with PoE
1 /6Pages

Catalog excerpts

T200 PTP Time Station, with PoE-1

DATA SHEET IEEE 1588 / PTP Client Time Station, with pulse generator, IRIG output, and event input. 1 Bd d’Armor – 22300 LANNION - FRANCE [email protected] 1 © 2015 All Rights Reserved. All specifications subject to change without notice.

 Open the catalog to page 1
T200 PTP Time Station, with PoE-2

DATA SHEET HEOL-T202 : PERFORMANCE and EASY INTEGRATION The T202 module is a PTP client station, able to synchronize automated systems and timestamp events in an industrial environment. As the T202 doesn’t integrate GPS antenna, you can install it anywhere in your system (it is just necessary to connect it to your LAN, so it can synchronize to an external PTP server – T200 GPS PTP master clock for example). Using the Precision Time Protocol (IEEE1588), the T102 can be synchronized with 1µs accuracy to PTP master clock. The PTP V2 implementation of the HEOL-T202 is fully compliant to the IEEE...

 Open the catalog to page 2
T200 PTP Time Station, with PoE-3

DATA SHEET Historic data can be backed-up to an EEPROM (over 8000 status records). The Power On Ethernet enables installation of the HEOL-T202x without the need for additional cables to provide power. It also offers redundancy of the AC/DC in case of failure of one of them. The T202 is available in 2 different metal housings, either compact or 19’’ rack mounted form factor. This rack unit displays on a LCD module the status and timing information. OCXO or TCXO Clock Event inputs External Events TOP/pps IRIG Sync outputs PTP + NTP (synchro and events) HTTP (config) SNMP (alarms and events) SMTP...

 Open the catalog to page 3
T200 PTP Time Station, with PoE-4

DATA SHEET Timing Ethernet protocol Configuration/monitoring Absolute timestamp error (refer to Master Clock) Timestamp drift when synchronization is lost RTC option Power supply Input Voltage Power consumption Interfaces Auxiliary DC Power Supply Remote RS232 / RS422 Ethernet link Alarm Relay pps output Event input Operating Temperature Storage Temperature Humidity Dimensions (T202C) Weight (T202C) Dimensions (T202R) Weight (T202R) PTP IEEE1588-2008 : - UDP/IPv4 - Addressing mode : Multicast & Unicast - Delay Mechanism : End-to-End - Operation : Two Step Clock - Sync & Announce Intervals : 1,...

 Open the catalog to page 4
T200 PTP Time Station, with PoE-5

DATA SHEET According to directive, the HEOL-T202 module has passed the following tests : EN55022/55011 class B : conducted and radiated emissions. EN61000-4-2: Immunity to electrostatic discharges. EN61000-4-3: Immunity tests on electromagnetic fields radiated at radioelectrical frequencies, with 10V/m electromagnetic field. EN61000-4-4: Immunity to rapid transients. EN61000-4-5: Immunity to surge. EN61000-4-6: Immunity tests on conducted interference, induced by radioelectrical fields. EN61000-4-8: Immunity to Power frequency magnetic field (30 A/m) EN61000-4-11: Voltage dips, short interruptions...

 Open the catalog to page 5
T200 PTP Time Station, with PoE-6

DATA SHEET ORDERING PART NUMBER T202R-100ns-AC-I/O-OCXOSR • Housing R: 19’’Rack C: Compact • PTP accuracy • Power DC : 14 to 60V DC/POE: DC+Power Ethernet AC : 110 to 250V (Rack only) • I/O option I/O connector mounted (blank : not mounted) • Oscillator option OCXOSR : standard (0 / +50°C) OCXOMR : medium (-20 / +65°C) OCXOHR : high (-40 / +70°C) If other options are needed, just add the part number of these options at the end of the T202 part number : -422 for RS422 serial port instead of RS232 -EVENT2 for secondary Event input -IRIG for IRIG-B003 output -PPSREL for PPS/TOP output on fast static...

 Open the catalog to page 6