Overview: The HEOL-T200 is a high-precision PTP/IEEE 1588 Grandmaster Clock and NTP Time Server equipped with a GPS/GNSS receiver. It is designed for network synchronization and measurement applications, providing accurate timing information via Ethernet without needing external network connections.
Specifications: The device features a 36-channel GPS chipset with high accuracy and supports GALILEO, GLONASS, and BEIDOU constellations. It offers microsecond synchronization through Precision Time Protocol (PTP) and is compliant with IEEE 1588-2008 standards. The T200 can operate in hold-over mode using an OCXO or Rubidium oscillator to maintain accuracy if satellite signals are lost.
Integration and Configuration: The T200 includes a web server for secure configuration and monitoring, with automatic email alerts for alarms. It supports SNMP for alarm display and configuration, and provides a highly accurate PPS signal. The device can be powered via Ethernet (PoE) and is available in various housing options, including compact, 19'' rack-mounted, and half-rack forms.
Environmental and Compliance: The T200 operates in temperatures ranging from -40°C to +85°C, depending on the option, and complies with several international standards, including EN55022/55011 for emissions and IEC/EN 60950 for safety. It is also RoHS compliant.
Ordering Information: The T200 is customizable with options for housing, PTP accuracy, power supply, I/O connectors, and oscillators. Additional options include RS422 serial ports, secondary event inputs, and various antenna connectors.
See more

Catalog excerpts

T200 PTP Grandmaster Clock-1

DATA SHEET T200, PTP/IEEE 1588 Grandmaster Clock and NTP Time Server with high accuracy GPS/GNSS receiver. Pole Phoenix – 22560 PLEUMEUR BODOU- FRANCE 1 © 2019 All Rights Reserved. All specifications subject to change without Notice.

 Open the catalog to page 1
T200 PTP Grandmaster Clock-2

HEOL-T200 : PERFORMANCE and EASY INTEGRATION The HEOL-T200 PTP IEEE-1588 Grandmaster Clock / NTP Time server with GPS Clock has been designed to provide accurate timing information trough an Ethernet link (using Precision Time Protocol), for Network synchronization and measurement applications, without the need to be connected to external Network, hence preserving your Network insulation. Based on a high performance 36 channels GPS chipset with very high accuracy, and TRAIM algorithm. GALILEO, GLONASS and BEIDOU constellations are also available as an option. It enables also fast start-up times...

 Open the catalog to page 2
T200 PTP Grandmaster Clock-3

DATA SHEET An isolated event input allows you to time-stamp events from external systems, with very high accuracy. The TimeStamp information is reported through RS232, SNMP trap, E-mail or Broadcast frame. Alarm relay is available, for driving your external systems in case of failure of the T200. Alarms are displayed through SNMP traps (Ethernet interface) or through RS232. SNMP can also be used to configure T200 parameters (instead of http web server). A highly accurate pps (TOP) signal is available on SUB-D9 or I/O connector (polarity, period, length, and delay compensation are configurable...

 Open the catalog to page 3
T200 PTP Grandmaster Clock-4

DATA SHEET GPS antenna Remote interface +NMEA OCXO or Rubidium Clock Event inputs External Events Sync outputs User systems PTP + NTP (synchro and events) HTTP (config) SNMP (alarms and events) SMTP (E-mail) Automated systems T200 synoptic and external links Note : Heol Design is not responsible for the operation or failure of operation of GPS satellites or the availability of GPS satellite signals. Pole Phoenix – 22560 PLEUMEUR BODOU- FRANCE 4 © 2019 All Rights Reserved. All specifications subject to change without Notice.

 Open the catalog to page 4
T200 PTP Grandmaster Clock-5

Pole Phoenix - 22560 PLEUMEUR BODOU- FRANCE [email protected] © 2019 All Rights Reserved. All specifications subject to change without Notice.

 Open the catalog to page 5
T200 PTP Grandmaster Clock-6

■ According to v ^ directive, the HEOL-T200 module has passed the following tests : > EN55022/55011 class B : conducted and radiated emissions. > EN61000-4-2: Immunity to electrostatic discharges. > EN61000-4-3: Immunity tests on electromagnetic fields radiated at radio-electrical frequencies, with 10V/m electromagnetic field. > EN61000-4-4: Immunity to rapid transients. > EN61000-4-6: Immunity tests on conducted interference, induced by radio-electrical fields. > EN61000-4-8: Immunity to Power frequency magnetic field (30 A/m) > EN61000-4-11: Voltage dips, short interruptions and voltage variations...

 Open the catalog to page 6
T200 PTP Grandmaster Clock-7

DATA SHEET T200 19’’ 1U Rack rear view (with ‘N’ antenna connector) 3&4 pins : Alarm relay or PPS/TOP output on Static relay (option PPSREL) 1&2 pins : Event input #1 5&6 pins : PPS/TOP RS422 output or IRIG B003 output (option IRIG) or Event input #2 (option EVENT2) I/O connector details Pole Phoenix – 22560 PLEUMEUR BODOU- FRANCE 7 © 2019 All Rights Reserved. All specifications subject to change without

 Open the catalog to page 7
T200 PTP Grandmaster Clock-8

ORDERING PART NUMBER DC/POE: DC+Power Ethernet AC : 110 to 250V (Rack only) • I/O option I/O connector mounted _l blank : not mounted (half-rack) • Oscillator option RUB : high stability Rubidium (Half-Rack or Rack) - 0 / +50°C blank : standard TCXO If other options are needed, just add the part number of these options at the end of the T200 part number : -422 for RS422 serial port instead of RS232 -EVENT2 for secondary Event input -PPSREL for PPS/TOP output on fast static relay -N or TNC connector option (N only for rack) -GNSS for GPS+GLONASS/GALILEO/BEIDOU instead of GPS only Pole Phoenix...

 Open the catalog to page 8