Product catalog summary
Introduction
The T116-FO is a GPS-synchronized time server designed for both static and mobile applications. It functions as an NTP/SNTP server and includes an IRIG modulated and un-modulated generator. It supports synchronization of distant IRIG clients via optical fiber and features a programmable pulse generator with multiple output options. The device includes an LCD display for timing and status information and offers daylight saving time management. An optional internal RTC provides time without GPS reference.

Specifications
The T116-FO features a 12-channel GPS receiver with high sensitivity and accuracy. It supports Ethernet configuration and monitoring via a web server or SNMP manager. The device maintains high timing accuracy even in poor signal conditions and includes a hold-over mode for signal loss. Power options include Power over Ethernet and auxiliary power supplies.

Interfaces and Connectivity
The T116-FO provides various interfaces including Ethernet, RS232/RS422, and multiple output options for synchronization signals. It supports SNMP for alarm notifications and configuration, and automatic email alerts. The device is compliant with several international safety and electromagnetic compatibility standards.

Ordering Information
The T116-FO can be customized with various options including power supply types, flash memory, OCXO options, and RTC for fast start. It supports multiple I/O configurations for event inputs and IRIG/PPS outputs. The total number of outputs is limited to eight.

Applications
An example application includes using the T116 for seismic impact measurement, demonstrating its versatility in integrating with various sensors and network systems.
See more

Catalog excerpts

T116-1

DATA SHEET T116, Time server 20 channels Event recorder IRIG & Pulse generator Fiber Optic outputs GPS disciplined Time Station, 20 events isolated inputs, IRIGB003, IRIGB123 and pulse generator, with isolated or optical outputs -Static and Mobile applications- 1 Bd d’Armor – 22300 LANNION - FRANCE [email protected] 1 © 2015 All Rights Reserved. All specifications subject to change without Notic

 Open the catalog to page 1
T116-2

The T116-FO time server is a time server, synchronized to GPS, providing the following functions : - NTP/SNTP server, broadcast and unicast modes. - IRIG modulated (B123) and un-modulated (B003) generator, available on BNC connector, optical port (SC connector), or isolated output. Coupled with the T047 optical/IRIG transceiver, you will have the ability to synchronize distant IRIG clients, linked to T116-FO server by an optical fiber (up to 2 km). - Programmable pulse generator, (up to 6 isolated, high current capacity outputs). Outputs are available on fast static relay, 5V, or differential...

 Open the catalog to page 2
T116-3

DATA SHEET The T116 provides Ethernet interface, for configuration via web server, automatic E-mails, SNMP access; Ethernet provides also accurate timing information trough the SNTP/NTP protocol. Thanks to its self-survey mode, the accuracy of the timestamp (compliant with SNTP protocol) is better than ±200 nanoseconds for the receive packet and ±600 nanoseconds for the transmit packet - reference is UTC atomic clock. If the satellites signals are completely lost, the hold-over mode enables the module to keep an accurate timing reference, with a maximum drift of 500µs/day (with OCXO option)....

 Open the catalog to page 3
T116-4

DATA SHEET RTC Clock generator OCXO/TCXO Remote interface +NMEA Event inputs External Events TOP/pps /IRIG/ 10MHz Sync outputs NTP/SNTP (synchro and events) http (config) SNMP (alarms and events) SMTP (E-mail) Automated systems T116 synoptic and external links 1 Bd d’Armor – 22300 LANNION - FRANCE [email protected] 4 © 2015 All Rights Reserved. All specifications subject to change without Notic

 Open the catalog to page 4
T116-5

1 Bd d'Armor - 22300 LANNION - FRANCE [email protected] 5 © 2015 All Rights Reserved. All specifications subject to change without Notice.

 Open the catalog to page 5
T116-6

■ According to v ^ directive, the HEOL-T116x module has passed the following tests : > EN55022/55011 class B : conducted and radiated emissions. > EN61000-4-2: Immunity to electrostatic discharges. > EN61000-4-3: Immunity tests on electromagnetic fields radiated at radio-electrical frequencies, with 10V/m electromagnetic field. > EN61000-4-4: Immunity to rapid transients. > EN61000-4-5: Immunity to surge. > EN61000-4-6: Immunity tests on conducted interference, induced by radio-electrical fields. > EN61000-4-8: Immunity to Power frequency magnetic field (30 A/m) > EN61000-4-11: Voltage dips,...

 Open the catalog to page 6
T116-7

DATA SHEET T116 with IRIG Fiber Optic outputs, rear view 3&4 pins : Alarm relay 1&2 pins : Event input channel1 5&6 pins : PPS/TOP RS422 output channel 1 T116 factory default I/O connections 1 Bd d’Armor – 22300 LANNION - FRANCE [email protected] 7 © 2015 All Rights Reserved. All specifications subject to change without Notic

 Open the catalog to page 7
T116-8

ORDERING PART NUMBER • Power DC : 14 to 60V DC/POE: DC+Power Ethernet AC : 110 to 250V AC/POE: AC+Power Ethernet • FLASH option : 128M flash _ memory to store Event data • OCXO option OCXOSR : standard (0 / +50°C) OCXOMR : medium (-20 / +65°C) OCXOHR : high (-40 / +70°C) • RTC option : for fast start without GPS satellites • DST option : Local Time and Daylight Saving Time management For the I/O options, just add the part number of these options at the end of the T116 part number : -xEVENT for Event input (x = 1 to 20); on I/O connector -xIRIG003 for IRIG-B003 output (x = 1 to 7) ; on I/O connector -xIRIG003b...

 Open the catalog to page 8
T116-9

DATA SHEET Annex : Example of use of T116 Event inputs for seismic impact measurement. seismic sensors Control room Data centre/ calculator 1 Bd d’Armor – 22300 LANNION - FRANCE [email protected] 9 © 2015 All Rights Reserved. All specifications subject to change without Notic

 Open the catalog to page 9