1. Catalogs
  2. heol design
  3. T116-M - Multi-event inputs Ruggedized Time server

T116-M - Multi-event inputs Ruggedized Time server
1 /9Pages

T116-M - Multi-event inputs Ruggedized Time server

T116-M - Multi-event inputs Ruggedized Time server
1 /9Pages

Catalog excerpts

T116-M - Multi-event inputs Ruggedized Time server-1

DATA SHEET T116, Time server 20 channels Event recorder IRIG & Pulse generator Fiber Optic outputs GPS disciplined Time Station, 20 events isolated inputs, IRIGB003, IRIGB123 and pulse generator, with isolated or optical outputs -Static and Mobile applications- 1 Bd d’Armor – 22300 LANNION - FRANCE [email protected] 1 © 2015 All Rights Reserved. All specifications subject to change without Notic

 Open the catalog to page 1
T116-M - Multi-event inputs Ruggedized Time server-2

The T116-FO time server is a time server, synchronized to GPS, providing the following functions : - NTP/SNTP server, broadcast and unicast modes. - IRIG modulated (B123) and un-modulated (B003) generator, available on BNC connector, optical port (SC connector), or isolated output. Coupled with the T047 optical/IRIG transceiver, you will have the ability to synchronize distant IRIG clients, linked to T116-FO server by an optical fiber (up to 2 km). - Programmable pulse generator, (up to 6 isolated, high current capacity outputs). Outputs are available on fast static relay, 5V, or differential...

 Open the catalog to page 2
T116-M - Multi-event inputs Ruggedized Time server-3

DATA SHEET The T116 provides Ethernet interface, for configuration via web server, automatic E-mails, SNMP access; Ethernet provides also accurate timing information trough the SNTP/NTP protocol. Thanks to its self-survey mode, the accuracy of the timestamp (compliant with SNTP protocol) is better than ±200 nanoseconds for the receive packet and ±600 nanoseconds for the transmit packet - reference is UTC atomic clock. If the satellites signals are completely lost, the hold-over mode enables the module to keep an accurate timing reference, with a maximum drift of 500µs/day (with OCXO option)....

 Open the catalog to page 3
T116-M - Multi-event inputs Ruggedized Time server-4

DATA SHEET RTC Clock generator OCXO/TCXO Remote interface +NMEA Event inputs External Events TOP/pps /IRIG/ 10MHz Sync outputs NTP/SNTP (synchro and events) http (config) SNMP (alarms and events) SMTP (E-mail) Automated systems T116 synoptic and external links 1 Bd d’Armor – 22300 LANNION - FRANCE [email protected] 4 © 2015 All Rights Reserved. All specifications subject to change without Notic

 Open the catalog to page 4
T116-M - Multi-event inputs Ruggedized Time server-5

1 Bd d'Armor - 22300 LANNION - FRANCE [email protected] 5 © 2015 All Rights Reserved. All specifications subject to change without Notice.

 Open the catalog to page 5
T116-M - Multi-event inputs Ruggedized Time server-6

■ According to v ^ directive, the HEOL-T116x module has passed the following tests : > EN55022/55011 class B : conducted and radiated emissions. > EN61000-4-2: Immunity to electrostatic discharges. > EN61000-4-3: Immunity tests on electromagnetic fields radiated at radio-electrical frequencies, with 10V/m electromagnetic field. > EN61000-4-4: Immunity to rapid transients. > EN61000-4-5: Immunity to surge. > EN61000-4-6: Immunity tests on conducted interference, induced by radio-electrical fields. > EN61000-4-8: Immunity to Power frequency magnetic field (30 A/m) > EN61000-4-11: Voltage dips,...

 Open the catalog to page 6
T116-M - Multi-event inputs Ruggedized Time server-7

DATA SHEET T116 with IRIG Fiber Optic outputs, rear view 3&4 pins : Alarm relay 1&2 pins : Event input channel1 5&6 pins : PPS/TOP RS422 output channel 1 T116 factory default I/O connections 1 Bd d’Armor – 22300 LANNION - FRANCE [email protected] 7 © 2015 All Rights Reserved. All specifications subject to change without Notic

 Open the catalog to page 7
T116-M - Multi-event inputs Ruggedized Time server-8

ORDERING PART NUMBER • Power DC : 14 to 60V DC/POE: DC+Power Ethernet AC : 110 to 250V AC/POE: AC+Power Ethernet • FLASH option : 128M flash _ memory to store Event data • OCXO option OCXOSR : standard (0 / +50°C) OCXOMR : medium (-20 / +65°C) OCXOHR : high (-40 / +70°C) • RTC option : for fast start without GPS satellites • DST option : Local Time and Daylight Saving Time management For the I/O options, just add the part number of these options at the end of the T116 part number : -xEVENT for Event input (x = 1 to 20); on I/O connector -xIRIG003 for IRIG-B003 output (x = 1 to 7) ; on I/O connector -xIRIG003b...

 Open the catalog to page 8
T116-M - Multi-event inputs Ruggedized Time server-9

DATA SHEET Annex : Example of use of T116 Event inputs for seismic impact measurement. seismic sensors Control room Data centre/ calculator 1 Bd d’Armor – 22300 LANNION - FRANCE [email protected] 9 © 2015 All Rights Reserved. All specifications subject to change without Notic

 Open the catalog to page 9
*Prices are pre-tax. They exclude delivery charges and customs duties and do not include additional charges for installation or activation options. Prices are indicative only and may vary by country, with changes to the cost of raw materials and exchange rates.