T116-M - Multi-event inputs Ruggedized Time server

T116-M - Multi-event inputs Ruggedized Time server

T116-M - Multi-event inputs Ruggedized Time server

Product catalog summary
Introduction
The T116-FO is a GPS-synchronized time server designed for both static and mobile applications. It functions as an NTP/SNTP server and includes an IRIG modulated and un-modulated generator, a programmable pulse generator, and a 20-channel event recorder. The device supports synchronization of distant IRIG clients via optical fiber and features a high-performance GPS receiver for accurate timing.

Specifications
The T116-FO features a 12-channel GPS receiver with a sensitivity of -155dBm and position accuracy of less than 2.5 meters. Time accuracy is ±100 ns for static and ±200 ns for mobile applications. It supports SNTP V4 protocol and offers configuration via HTTP server or SNMP manager. The device can maintain accurate timing even if GPS signals are lost, with a drift of 500µs/day (OCXO) or 5µs/day (Rubidium).

Interfaces and Power Supply
The device includes various interfaces such as Ethernet, RS232/RS422, and multiple output options for IRIG and PPS signals. It supports Power over Ethernet (PoE) and auxiliary power inputs ranging from 14 to 60 VDC or 85/250 VAC.

Environmental and Compliance
The T116-FO operates in temperatures from 0/50°C to -40/+85°C, depending on the option, and complies with several international standards for emissions and immunity. It is also RoHS compliant.

Ordering Information
Various configurations are available, including options for power supply, flash memory, oscillator type, and additional I/O options. The total number of outputs cannot exceed eight.

Applications
An example application includes using the T116 for seismic impact measurement, demonstrating its versatility in different monitoring and synchronization tasks.
See more

Catalog excerpts

T116-M - Multi-event inputs Ruggedized Time server-1

DATA SHEET T116, Time server 20 channels Event recorder IRIG & Pulse generator Fiber Optic outputs GPS disciplined Time Station, 20 events isolated inputs, IRIGB003, IRIGB123 and pulse generator, with isolated or optical outputs -Static and Mobile applications- Route radome – 22560 PLEUMEUR BODOU FRANCE - [email protected] 1 © 2018 All Rights Reserved. All specifications subject to change without Notice.

 Open the catalog to page 1
T116-M - Multi-event inputs Ruggedized Time server-2

The T116-FO time server is a time server, synchronized to GPS, providing the following functions : - NTP/SNTP server, broadcast and unicast modes. - IRIG modulated (B123) and un-modulated (B003) generator, available on BNC connector, optical port (SC connector), or isolated output. Coupled with the T047 optical/IRIG transceiver, you will have the ability to synchronize distant IRIG clients, linked to T116-FO server by an optical fiber (up to 2 km). - Programmable pulse generator, (up to 6 isolated, high current capacity outputs). Outputs are available on fast static relay, 5V, or differential...

 Open the catalog to page 2
T116-M - Multi-event inputs Ruggedized Time server-3

DATA SHEET cabling and lightning strike protection and reduces the cost of maintenance. The T116 provides Ethernet interface, for configuration via web server, automatic E-mails, SNMP access; Ethernet provides also accurate timing information trough the SNTP/NTP protocol. Thanks to its self-survey mode, the accuracy of the timestamp (compliant with SNTP protocol) is better than ±200 nanoseconds for the receive packet and ±600 nanoseconds for the transmit packet - reference is UTC atomic clock. If the satellites signals are completely lost, the hold-over mode enables the module to keep an accurate...

 Open the catalog to page 3
T116-M - Multi-event inputs Ruggedized Time server-4

DATA SHEET RTC Clock generator OCXO/TCXO Event inputs External Events Remote interface +NMEA Sync outputs NTP/SNTP (synchro and events) http (config) SNMP (alarms and events) SMTP (E-mail) Automated systems T116 synoptic and external links Route radome – 22560 PLEUMEUR BODOU FRANCE - [email protected] 4 © 2018 All Rights Reserved. All specifications subject to change without Notice.

 Open the catalog to page 4
T116-M - Multi-event inputs Ruggedized Time server-5

Route radome - 22560 PLEUMEUR BODOU FRANCE - [email protected] 5 © 2018 All Rights Reserved. All specifications subject to change without Notice.

 Open the catalog to page 5
T116-M - Multi-event inputs Ruggedized Time server-6

■ According to v ^ directive, the HEOL-T116x module has passed the following tests : > EN55022/55011 class B : conducted and radiated emissions. > EN61000-4-2: Immunity to electrostatic discharges. > EN61000-4-3: Immunity tests on electromagnetic fields radiated at radio-electrical frequencies, with 10V/m electromagnetic field. > EN61000-4-4: Immunity to rapid transients. > EN61000-4-6: Immunity tests on conducted interference, induced by radio-electrical fields. > EN61000-4-8: Immunity to Power frequency magnetic field (30 A/m) > EN61000-4-11: Voltage dips, short interruptions and voltage variations...

 Open the catalog to page 6
T116-M - Multi-event inputs Ruggedized Time server-7

DATA SHEET T116 with IRIG Fiber Optic outputs, rear view 3&4 pins : Alarm relay 1&2 pins : Event input channel1 5&6 pins : PPS/TOP RS422 output channel 1 T116 factory default I/O connections Route radome – 22560 PLEUMEUR BODOU FRANCE - [email protected] 7 © 2018 All Rights Reserved. All specifications subject to change without Notice.

 Open the catalog to page 7
T116-M - Multi-event inputs Ruggedized Time server-8

ORDERING PART NUMBER DC/POE: DC+Power Ethernet AC : 110 to 250V AC/POE: AC+Power Ethernet • FLASH option : 128M flash memory to store Event data • Oscillator option _ • RTC option : for fast start without GPS satellites - • DST option : Local Time and Daylight Saving Time management — For the I/O options, just add the part number of these options at the end of the T116 part number : -xEVENT for Event input (x = 1 to 20); on I/O connector -xIRIG003 for IRIG-B003 output (x = 1 to 7) ; on I/O connector -xIRIG003b for IRIG-B003 output (x = 1 to 7) ; on BNC connector -xIRIG123 for IRIG-B123 output...

 Open the catalog to page 8
T116-M - Multi-event inputs Ruggedized Time server-9

DATA SHEET Annex : Example of use of T116 Event inputs for seismic impact measurement. seismic sensors Control room Data centre/ calculator Route radome – 22560 PLEUMEUR BODOU FRANCE - [email protected] 9 © 2018 All Rights Reserved. All specifications subject to change without Notice.

 Open the catalog to page 9